7
Lo
Standard = 37
3/4”
, EG = 47
1/4”
Z min = 2”
S < 0
S = 0
S > 0
y Standard = 3”
y EG= 4”
FAAC 400 Hydraulic Swing Gate Operator
If the dimensions indicated in table A or B cannot be
achieved, the following must be considered in order to
calculate different measurements:
•
To obtain 90° opening of the leaf:
a + b = c
.
•
To obtain over 90° opening of the leaf:
a + b < c
.
•
Lower
a and b
dimensions will result in higher speeds.
•
Limit the difference between
a and b
to within 1.5 inches.
Higher differences will considerably vary gate opening and
closing speed.
•
The minimum
Z
dimension is 2 inches (Fig. 4);
•
If the pillar dimensions or the position of the hinge
(dimension
d
) do not make it possible to keep dimension
a
at the required size, a niche must be made in the pillar as
shown in Fig. 5.
•
Dimension
a
must always be larger than dimension
E
.
For installations that open outward, refer to Section 9.1.
Figure 4
3. INSTALLING THE MODEL 400
3.2. Installation Dimensions
To ensure a correctly operating automated system, the struc-
ture of the gate must satisfy the following requirements:
•
Leaf length should not exceed “Max Leaf Length” dimensions
in Table 1.
•
Gate should have a strong and rigid leaf structure.
•
Gate leaves should have a smooth, uniform movement du-
ring the entire length of travel without any irregular friction.
•
Existing hinges should be in good condition.
•
Travel limit mechanical stops must be provided.
•
Perform all metal work before installing the automated gate
operator system.
•
The condition of the structure directly influences the reliability
and safety of the automated system.
Attention
: To avoid compromising operator functionality, use
measurements and dimensions indicated.
1.)
Fasten the rear attachment to a pillar or column
support. Follow the measurements indicated in Tables
A / B. If necessary, modify the length of the supplied
attachment.
•
For iron pillars, weld the rear attachment (Fig. 6,
Ref. 2) directly to the pillars.
•
For masonry pillars, select one of the following
solutions:
A.) Install an appropriate wall plate and then
accurately weld the rear attachment.
OR
B.) Use screws and expansion plugs to secure the
rear attachment plate (Fig. 6, Ref. a) to the pillar.
Then weld the rear attachment to the plate as
shown in Figure 6.
Table B: Recommended Dimensions for EG Operators
(*) Rod effective stroke (**) maximum dimension
Opening Angle
a
b
c(*)
d(**)
s
90°
7 7/8
6 1/4
15
5 7/8
3/4
115°
6 3/4
6 1/4
15
4 3/8
3/4
125°
5 1/8
6 3/4
15
3 1/8
3/4
Opening Angle
a
b
c(*)
d(**)
s
90°
5 1/16
5 1/16
10 1/4
3 1/8
3/4
115°
4
4 3/4
10 1/4
2
3/4
125°
3 1/2
4 3/4
10 1/4
1 1/2
0
Table A: Recommended Dimensions for Standard Operators
(*) Rod effective stroke (**) maximum dimension
c = In order to prevent the rod from reaching its stop point
internally when opening and closing, the effective rod
stroke is shorter than the maximum stroke.
3.1. Preliminary Checks
- in inches
3.3 General Rules for Determining Installation
Dimensions
3.4. Installing the Operator
- in inches
Figure 5
Содержание 400
Страница 2: ......
Страница 29: ...27 FAAC 400 Hydraulic Swing Gate Operator 15 PREWIRED ENCLOSURE DIAGRAM ...