The 

activating devices and radio receiver for your gate 

must have normally open (N.O.) contacts. Connect 

such devices to terminals OPEN A and COM. 

 

N

OTE

:

 The FAAC radio receiver plugs into 

the 5 prongs labeled CN5 (Quick connect 

port). 

 

Page 19 shows how to connect a three or four wire 

receiver. 

 

FAAC PLUG IN RADIO RECIEVER:

 

If you are 

installing the FAAC Receiver use the quick-fit 

connector CN5. 

 

N

OTE

If  your  using  both  a  receiver  and 

decoder, hard wire the decoder and plug in 

the receiver. 

 

O

PEN

/H

OLD

  O

PEN

  D

EVICE

To open and hold open 

the gate, simply maintain a contact across terminals 

OPEN A and COM.  (“A” Mode only) 

  

S

TOP

  B

UTTON

The stop button you install must 

have normally closed (N.C.) contacts. Multiple stop 

buttons must be wired in series. Connect your stop 

device between terminals STOP and COM. 

 

N

OTE

: The 425 D will not operate the motors 

without a closed circuit between STOP & COM. 

 

The LED Indicators

The nine light emitting 

diodes (LEDs) on the control panel can be used to 

check for the proper function of the devices 

attached to the panel. The LED lights are on 

whenever the contacts are closed across each of the 

respective terminals. 

LED 

On 

Off 

DL1 

Power On 

Power Off 

DL7 
FSW CL 

Closing 

Safeties Normal 

Closing 

Safeties 

Triggered 

DL8 
FSW OP 

Opening 

Safeties Normal 

Opening 

Safeties 

Triggered 

DL3 
STOP 

Stop Device 

Normal 

Stop Signal 

Given 

DL2,DL3 
DL4,DL5 
Limits 

Limit Switches  

Normal 

Limit Switches 

Triggered 

T

HE

 425 D C

ONT

R

OL

 P

ANE

L

 I

NSTALLA

T

ION

 I

NS

TRUCTIONS

 

OP_A and OP_B (Partial Opening) should illuminate only 

when an activating signal is sent for 2 and 1 gate leaves, 

respectively. STOP should be illuminated except when 

the stop button is pressed. FSWOP and FSWCL should be 

illuminated except when the reversing devices, for 

opening and closing, respectively, are triggered. Use the 

LEDs and the next table to determine if the accessory 

devices you have installed are operating properly. 

 

Electric Locks: 

An electric lock can be wired to the 

425 D in 

terminals ELS and ELS (24Vdc pulsed 

provided). If a reversing stroke is needed to allow the 

electric lock to release, this must be done in 

 

programming. 

 

See page 19 for the connections for a magnetic locking 

device. 

 

W

ARNING

  L

IGHT

Connect a warning light to 

terminals labeled lamp in the CN2 terminal block. 

The terminals provide an output voltage of 24 VDC, 

maximum power 15 Watts. This output voltage will 

power most 24 VDC warning lights. 

 

N

OTE

The behavior of the warning light is as 

follows. During programming the light will flash 

every 1/2 second during opening and every 1 1/2 

seconds during closing. If you are in automatic 

mode (A), upon reaching the open position, the 

output will remain on for 5 seconds to inform you 

that  the  gate  will  close  automatically.  It  will  also 

flash for up to 10 seconds if the gate is open and a 

safety is triggered. 

 

The output can also be set as a courtesy light that stays 

illuminated for 90 seconds. See the programming 

section (G0 and G1) for further details 

S

ET

 O

THER

 O

PERATING

 C

ONTROLS

 

 
WARNING

! Turn the main power off before you 

make any electrical connections. 

 

You need to program the control panel for your gate's 

operation. The 425 D Control Panel has on board 

programming that controls a wide range of functions. 

 

O

PERATING

 L

OGICS

 

 

N

OTE

: The 425 D Control Panel provides inputs 

for opening reversing devices and closing 

reversing devices. FAAC strongly recommends 

the use of reversing devices, such as photocells 

or other non-contact sensors. 

 

• 

A (automatic):

 

The gate opens on command 

and automatically closes after a pause phase. A 

second command while opening is ignored; a 

second command during the pause phase 

interrupts the pause time; a second command 

Содержание 390 24 V

Страница 1: ...6 Install the Operator 7 Mounting Dimensions 7 Mounting the Base Plate 7 390 Limit Switch Instructions 10 Exploded View 390 24V Operator 12 390 24V Operator Parts List 13 The 425 D Control Panel Gene...

Страница 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Страница 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Страница 4: ...ximum leaf length ft m 14 3 Maximum leaf swing deg 120 Figure 1 390 Operator Dimensions 2 3 8 4 13 1 16 9 7 8 1 4 3 8 4 5 1 6 15 3 4 1 1 3 4 5 1 2 2 3 8 16 1 8 5 1 8 5 1 8 Parameter Measure Motor RPM...

Страница 5: ...te any damage because the carrier must witness the damage before you can file a claim As you unpack the box insure that all the parts listed below are included See Figure 2 Control panel enclosure wit...

Страница 6: ...et during Basic Programming of the 425 D Control Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing o...

Страница 7: ...hose indicated in the technical specifications Make sure that the leaves move properly without any binding during their entire travel Check if hinges are in good condition Make sure the positive stops...

Страница 8: ...el Installation Manual A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26 90 2 4 7 8 25 120 4 6 9 10 23 120 6 8 11 12 21 120 8 10 12 13 20 120 Figure 5 D...

Страница 9: ...ual Figure 6 Typical overhead outward swing mounting dimensions for garage carriage door applications A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26...

Страница 10: ...mit Switches Open and Closed Stops Figure 7 Figure 8 Figure 9 Figure 7 shows how to attach the operator to the base plate Figure 8 shows how to assemble the articulated arm and front bracket Figure 9...

Страница 11: ...gate 1 Operator Wire Gauges for Given Voltage 2 Control Panel Enclosure 110 VAC primary 24 VAC 100 VA secondary 3 Photocell A 2 18 AWG A 2 18 AWG 4 Power Switch B 4 14 AWG B 4 14 AWG 5 FAAC 5 Wire Cab...

Страница 12: ...Page 12 July 2006 390 24v Operator And 425 D Control Panel Installation Manual The 390 24v Operator...

Страница 13: ...13 N A Manual Release Outer 1 14 722471 Mounting Frame 1 15 N A Bushing Brass Bottom 1 16 N A Fender Washer 1 17 N A Motor 24VDC 1 20 N A Motor Housing 24VDC 1 21 N A Snap Ring 1 22 N A Seal Lower 1 2...

Страница 14: ...operator to the control panel Checking the direction of the motor s rotation Connecting other devices to the control panel Set operating modes CONNECT THE MAIN POWER SUPPLY WARNING Turn the main power...

Страница 15: ...be used to power 24 VDC accessories NOTE The 425 D control panel allows a maximum accessory load of 630mA REVERSING DEVICES Reversing devices include photocells inductive loops and so forth All of the...

Страница 16: ...OP and FSWCL should be illuminated except when the reversing devices for opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have i...

Страница 17: ...ted gate operator s b Op 1 Op 2 OP CL OP CL CN2 CN2 terminal strip 425 D Control Panel Ground CN3 CN4 To the U L Listed gate operator To the U L Listed control panel U L Listed cord grip Junction box...

Страница 18: ...Photocells 3 4 Wire Radio Receivers DC Radios Only N C N O COM 24 vdc Relay 1 2 1 2 3 4 5 Additional Reversing Devices TX RX NO C If 4 Wire Receiver Activation Devices Free Exit Loop Phone Keypad C N...

Страница 19: ...ore you make any electrical connections or set any switches inside the control panel box To program the automated system the Programming Mode must be accessed The 425D has two push buttons labeled P1...

Страница 20: ...he open direction touch the two RESET JMP1 pins see figure 2 with a small screwdriver or piece of wire This will cause the gate to stop 6 Turn the power off to the control panel and reverse the motor...

Страница 21: ...oth directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the prope...

Страница 22: ...he reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversing device is triggered If either does not illuminate then one of your reversing devices is preventi...

Страница 23: ...Page 23 July 2006 390 24v Operator And 425 D Control Panel Installation Manual NOTES...

Страница 24: ...dance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Отзывы: