390 Limit Switch Instructions 

When Using 1 Limit Switch (Open or Closed Stop) 

When Using 2 Limit Switches (Open and Closed Stops) 

 

Figure 7 

Figure 8 

Figure 9 

Figure 7 shows how to attach the operator 
to the base plate. 

Figure 8 shows how to assemble the articulated 

arm and front bracket. 

Figure 9 shows how to attach the articulated 
arm and operator cover to the operator. 

Figure 10 shows how to attach the front mounting 

bracket to the gate leaf(s).

 

Figure 10 

 

 

Figure 10 

Содержание 390 24 V

Страница 1: ...6 Install the Operator 7 Mounting Dimensions 7 Mounting the Base Plate 7 390 Limit Switch Instructions 10 Exploded View 390 24V Operator 12 390 24V Operator Parts List 13 The 425 D Control Panel Gene...

Страница 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Страница 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Страница 4: ...ximum leaf length ft m 14 3 Maximum leaf swing deg 120 Figure 1 390 Operator Dimensions 2 3 8 4 13 1 16 9 7 8 1 4 3 8 4 5 1 6 15 3 4 1 1 3 4 5 1 2 2 3 8 16 1 8 5 1 8 5 1 8 Parameter Measure Motor RPM...

Страница 5: ...te any damage because the carrier must witness the damage before you can file a claim As you unpack the box insure that all the parts listed below are included See Figure 2 Control panel enclosure wit...

Страница 6: ...et during Basic Programming of the 425 D Control Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing o...

Страница 7: ...hose indicated in the technical specifications Make sure that the leaves move properly without any binding during their entire travel Check if hinges are in good condition Make sure the positive stops...

Страница 8: ...el Installation Manual A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26 90 2 4 7 8 25 120 4 6 9 10 23 120 6 8 11 12 21 120 8 10 12 13 20 120 Figure 5 D...

Страница 9: ...ual Figure 6 Typical overhead outward swing mounting dimensions for garage carriage door applications A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26...

Страница 10: ...mit Switches Open and Closed Stops Figure 7 Figure 8 Figure 9 Figure 7 shows how to attach the operator to the base plate Figure 8 shows how to assemble the articulated arm and front bracket Figure 9...

Страница 11: ...gate 1 Operator Wire Gauges for Given Voltage 2 Control Panel Enclosure 110 VAC primary 24 VAC 100 VA secondary 3 Photocell A 2 18 AWG A 2 18 AWG 4 Power Switch B 4 14 AWG B 4 14 AWG 5 FAAC 5 Wire Cab...

Страница 12: ...Page 12 July 2006 390 24v Operator And 425 D Control Panel Installation Manual The 390 24v Operator...

Страница 13: ...13 N A Manual Release Outer 1 14 722471 Mounting Frame 1 15 N A Bushing Brass Bottom 1 16 N A Fender Washer 1 17 N A Motor 24VDC 1 20 N A Motor Housing 24VDC 1 21 N A Snap Ring 1 22 N A Seal Lower 1 2...

Страница 14: ...operator to the control panel Checking the direction of the motor s rotation Connecting other devices to the control panel Set operating modes CONNECT THE MAIN POWER SUPPLY WARNING Turn the main power...

Страница 15: ...be used to power 24 VDC accessories NOTE The 425 D control panel allows a maximum accessory load of 630mA REVERSING DEVICES Reversing devices include photocells inductive loops and so forth All of the...

Страница 16: ...OP and FSWCL should be illuminated except when the reversing devices for opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have i...

Страница 17: ...ted gate operator s b Op 1 Op 2 OP CL OP CL CN2 CN2 terminal strip 425 D Control Panel Ground CN3 CN4 To the U L Listed gate operator To the U L Listed control panel U L Listed cord grip Junction box...

Страница 18: ...Photocells 3 4 Wire Radio Receivers DC Radios Only N C N O COM 24 vdc Relay 1 2 1 2 3 4 5 Additional Reversing Devices TX RX NO C If 4 Wire Receiver Activation Devices Free Exit Loop Phone Keypad C N...

Страница 19: ...ore you make any electrical connections or set any switches inside the control panel box To program the automated system the Programming Mode must be accessed The 425D has two push buttons labeled P1...

Страница 20: ...he open direction touch the two RESET JMP1 pins see figure 2 with a small screwdriver or piece of wire This will cause the gate to stop 6 Turn the power off to the control panel and reverse the motor...

Страница 21: ...oth directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the prope...

Страница 22: ...he reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversing device is triggered If either does not illuminate then one of your reversing devices is preventi...

Страница 23: ...Page 23 July 2006 390 24v Operator And 425 D Control Panel Installation Manual NOTES...

Страница 24: ...dance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Отзывы: