EZY SWITCH
LIMITED
SMS-2
System Monitor
Installation Manual
Страница 1: ...EZY SWITCH LIMITED SMS 2 System Monitor Installation Manual ...
Страница 2: ...the Input reply messages 16 Commands to Control Outputs Turn an Output ON or OFF 17 Turn an Output ON for a set time 17 Invert Output 17 Make an Output Pulse On and Off 18 Make an Output pulse every xx hours 18 Make an output public 19 Turn Output response On Off 19 Save Output Status 19 Link Outputs 19 Customize Text Messages for Outputs Programming the Output reply messages 20 Battery Monitoring...
Страница 3: ...d Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Example Link intruder sensor or smoke detector input to light or alarm horn output Monitors battery supply voltage and sends alarm message if low battery is detected at below the programmed alarm setting On demand upda...
Страница 4: ...s Ezy Switch Ltd System Ezy Switch SMS 2 Installation Operation Manual SIM Card Supply Voltage Quiescent Current Data Retention Outputs Max Input voltage 12 to 30 Volts DC 800mA 20 Milli amps 10 years without power Relay 3 A resistive 125VAC 30vdc SMS 2 Terminal Electrical Specifications Terminal 1 Batt Terminal 2 Batt Terminal 3 Input 1 Terminal 7 Ouput 1 N O Terminal 4 Input 1 Terminal 8 Output ...
Страница 5: ... 125VAC Relay 1 Connection Internal Relay Relay Terminals 7 8 Outputs Ezy Switch SMS 2 Installation Operation Manual Important Note A registered electrician must be used when connecting to the 120 240v main supply voltage Relay 2 Connection Internal Relay Relay Terminals 9 10 ...
Страница 6: ...r Fig 1a Fig1b or Fig 2 Inputs Ezy Switch SMS 2 Installation Operation Manual SMS 2 Input 1 Terminal 4 Switch 10 30vdc Fig 1a SMS 2 Input 2 Terminal 6 Switch 10 30vdc Fig 1b SMS 2 Terminal 3 Switch Input1 Fig 2 Switch Input2 Terminal 4 Terminal 5 Terminal 6 ...
Страница 7: ...mber without the preceding 0 If the users number is 0412882900 then Command add user 65412882900 USA Canada 001 1 and the Area Code Number If the users number is 412 555 1234 then Command add user 14125551234 IMPORTANT Ezy Switch SMS 2 Installation Operation Manual NOTE If a user sends a text message to the system which is not an exact match with the commands the system responds with Sorry either ...
Страница 8: ... number XXXXXXXX has been added to the user list Removing a User Command Remove user XXXXXXXX see Country Code page 7 If you try to remove the only user the system responds with Cannot delete the only user If the number sent is not currently on the list the system responds with XXXXXXXX is not currently on the user list so cannot be removed please check the number and try again If everything is ok...
Страница 9: ... the unit using the Add User command as per above If User lookup is Off the SMS 2 will respond to any number that sends the correct command The system responds with The user lookup list feature has been turned on and the unit will only accept commands from programmed users OR The user lookup list feature has been turned off and the unit will accept commands from any numbers PLEASE NOTE Input chang...
Страница 10: ...is if you are present and can trigger the inputs The system responds with Battery is currently volts signal strength is run test now The unit will now test the inputs and outputs and waits for the inputs to be triggered When input1 is turned on output1 will turn on when input1 is turned off output1 will turn off When input2 is turned on output2 will turn on when input2 is turned off output2 will t...
Страница 11: ...st the system responds with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chosen does not fulfill the requirements of a name the system responds with Sorry that name is not allowed please check that it is between 1 and 20 characters long If everything is ok the system responds with The input name has been cha...
Страница 12: ... Command Make INPUT NAME latching Example Make alarm latching This sets the Input to a latched Input and the system responds with The Input INPUT NAME is now a latching input Set an Input as a Non latched Input Command Make INPUT NAME nonlatching Example Make alarm non latching This sets the Input to a NON latched Input and the system responds with The Input INPUT NAME is now a nonlatching input R...
Страница 13: ...The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 5 minutes or see Set Reminder Text Time page 14 until the text command Tick INPUT NAME off is sent max number of texts 100 To turn the feature on Command Make INPUT NAME tickoff on If everything is fine the system responds with The input tickoff feature has been turned on...
Страница 14: ...minder text will be sent to the users in the list one at a time every 5 minutes see below until the text command Tick INPUT NAME off is sent To turn the feature on Command Step only numbers on The system responds with The tick off number only step feature has been turned on NOTE The difference between the above commands is Step numbers on will text all users then one at a time every 5 minutes Step...
Страница 15: ...ple The system responds with The user list in order is x x x x Example if you wanted users 2 4 7 8 in the schedule list Command Set tickoff order 2 4 7 8 The system responds with The user list in order is 2 4 7 8 If the input that has been set up as a tick off input is triggered user 2 will receive the first text 5 minutes latter user 4 will receive the next text 5 minutes latter user 7 the next t...
Страница 16: ...essage1 The Command for Input2 is Message2 If everything is fine the system responds with The reply message has been set back to the factory settings Programming the Input Off reply message only available in ver 5 8 or later If this feature is programmed then when the input turns Off you will receive the programmed message The programmed message can have up to 6 words and a maximum of 10 character...
Страница 17: ...put Off command is sent The Output on time XX can also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the system responds with The OUTPUT NAME on time has been set to XX mins or hrs or days If no value is set the system will respond with The OUTPUT NAME has...
Страница 18: ...n Input when the Input is triggered the system sends INPUT NAME linked output OUTPUT NAME has been pulsed on then off Clear Output pulse make output non pulsing Command Clear OUTPUT NAME pulse If you try to clear a pulsed Output when it is not set the system responds with OUTPUT NAME is not currently a pulsed output so does not need changing If you try and clear a pulse on an Input the system resp...
Страница 19: ...is feature has been disabled response text will not be sent Save Output Status This command is used to define if the output state is saved to memory and restored to it state after a power recycle E g if an output was On when the power was turned off then when the power is restored the output will turn back on Note this does not apply if an output was turned on for a specified time System default i...
Страница 20: ...essage2 output If everything is fine the system responds with The reply message has been set back to the factory settings Programming the Output Off reply message only available in ver 5 8 or later If this feature is programmed then when the output turns Off you will receive the programmed message The programmed message can have up to 6 words and a maximum of 10 characters per word e g The pump ha...
Страница 21: ... the alarm has been reset If the value XX X is outside the settings the system responds with Because the value is out of range the voltage alarm has been set to 11 5 volts and the alarm has been reset Link the Battery Alarm to an Output Command Link battery alarm to OUTPUT NAME The system responds with The battery alarm has successfully been linked to OUTPUT NAME and the alarm has been reset To cl...
Страница 22: ...larm has been cleared and will begin to be monitored again the linked output has also been turned off If the alarm is not currently set the system responds with The battery alarm is not currently active and does not need to be cleared Alive text feature only available in ver 1 2 or later This unit has an alive text feature which will send out a alive text as often as it has been programmed for To ...
Страница 23: ... turned on at node 2 then output 2 will turn on node 1 If the input turns off the output will turn off To be able to use the SMS 2 controller point to point function follow these instructions SMS 2 node A contains SIM card telephone 1 SMS 2 node B contains SIM card telephone 2 After adding the node numbers the original Set User number may be removed please see Removing a User page 8 Setting of nod...
Страница 24: ...lse counter and setup input2 override with the one command Command Trigger counter with input2 If everything is fine the system responds with Input1 has been set as a counter input and linked to input2 3 Make input a pulse counter This command will setup input1 as a pulse counter only Command Make input counter If everything is fine the system responds with Input1 counter feature has been turned o...
Страница 25: ... if linked with output1 optional then output1 will turn off see below Note mm has to be a whole number e g 3mm 4mm Command Set counter setpoint to YYY where a number e g 120 where YYY will be litres or gallons or mm If everything is fine the system responds with Setpoint set to YYY where YYY will be litres or gallons or mm When the setpoint value is reached a text will be sent The setpoint has bee...
Страница 26: ...f the counter is linked to output1 the system responds with The input counter has been reset to zero and output1 has been turned on If the counter is linked to output2 the system responds with The input counter has been reset to zero and output2 has been turned off Starting and Stopping the Count pulse every xx This command allows you to start or stop the automatic sending of the pulse counter as ...
Страница 27: ...em responds with The hour meter has been set to xxx hours and an alert text will be sent when value has been reached PLEASE SEE NEXT COMMAND Set hour meter alarm text number or numbers If the hour meter alarm has been set up as above you NEED to program the numbers that the alarm text is sent to Only these numbers will receive the alarm text Note These numbers need to be added as normal see Adding...
Страница 28: ...e been sent while it was in sleep mode these texts will be serviced and the unit will then go back to sleep Command Set sleep time to XX YY XX can be between 1 to 99 YY can be either minutes hours or days max time 99 days e g To place the unit in sleep mode for 12 hours Command Set sleep time to 12 hours The system responds with The sleep time has been set and the unit will wake up every XX YY Sle...
Страница 29: ...ture only available in ver 6 6 or later For applications where motor or other circuits are controlled from the SMS 2 unit s output and the connected load must be stopped by either manual stop switch or sensor such as a pressure switch on pumping applications Opening the output uses the SMS s internal logic and therefore is instantaneous Note that text message commands to turn off the output are st...
Страница 30: ... Command Irrigator3 On this will turn the feature On Or Command Irrigator3 Off this will turn the feature Off The system responds with The irrigator3 feature has been turned can be on or off Pump Controller only available in ver 6 5 or later If the SMS 2 is used with the SMS T4 or SMS T8 as the Pump controller OR If the SMS 2 is used with the SMS TEMP 4 or SMS TEMP 8 as the Pump controller After s...
Страница 31: ...ng No Service GSM GPRS EGPRS EDGE WCDMA HSDPA only HSUPA only HSPA HSDPA and HSUPA Resetting the Unit Command Reboot The system responds with Module is now resetting Reset Unit to Factory Defaults WARNING This command restores the unit to factory defaults therefore all settings will be lost Command Factory Reset The unit responds with The unit has been restored to factory settings and all memory h...
Страница 32: ...replaced product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agents accept any liability for any direct indirect or consequential losses or damages whatsoever or howsoever arising from the use of the product Where conditions or warranties are implied or other right...
Страница 33: ...f before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it will also state the linked output has also been turned on Off Delay This delay is used when the input turns OFF Example If input1 has an OFF delay of 10mins when Input1 turns OFF the unit will wait 10 minutes then send the following text message Input Name has been ...
Страница 34: ...e aerial with high gain aerial 2 Move unit to different location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM network hence the slow flashes but the signal strength is to low 1 Replace aerial with high gain aerial 2 Move unit to different location 3 SIM card NOT regist...
Страница 35: ... into a conveniently located 120 240v AC outlet on board your vessel and wired as shown in the diagram below fig 1 Name this Input Shore Power using the Command on page 11 If shore power is lost the SMS 2 will send a text message to all users saying Shore Power has turned off To avoid any nuisance text message s caused by a tripped breaker or someone temporarily using your power outlet you should ...
Страница 36: ...and is now latched When the alarm has been triggered you can reset it by sending the txt Reset Sensor If you want to connect a siren and or flashing light to output1 then Send command text Link Sensor to output1 Send command text Change output1 to Siren When the unit detects movement you will receive a text message and the siren and or flashing light will turn On The input Sensor has been turned o...
Страница 37: ...open when activated When the unit detects movement you will receive the following text message The input Door Sensor has been turned on and is now latched When the alarm has been triggered you can reset it by sending the txt Reset Door Sensor If you want to connect a siren and or flashing light to output1 then Send command text Link Door Sensor to output1 Send command text Change output1 to Siren ...
Страница 38: ...turn the Air Con On and pulsed On and Off to be turned Off The SMS 2 has a special command for this type 1 Connect the Air Con to Output1 2 To turn On send Air On Output1 will pulse On and Off trigging the Air Con On 3 To turn Off send Air off Output1 will pulse On and Off trigging the Air Con Off Type2 Heating If the brand requires that the Output be pulsed On and Off to turn the Heating On and p...
Страница 39: ...39 All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 2 3 ...