Turn an Output ON or OFF
Command:
Turn OUTPUT NAME on (or) off
(Example: Turn Generator on)
If everything is fine, the system responds with:
OUTPUT NAME
has been turned off (or) on
This command is used to turn on/off Outputs. If the item named is not an Output or the
command is not spelt correctly the system responds with:
Sorry either that output does not exist or the options ON or OFF has not been used
Turn an Output ON for XX mins or hrs or days
Command:
Turn OUTPUT NAME on for XX (either mins or hrs or days)
If everything is fine, the system responds with:
OUTPUT NAME
has been turned on for XX (mins or hrs or days)
XX can be between 1 to 99 either minutes or hours or days (max time 99 days)
Ver 5.7 or higher XX can be between 1 to 999 either minutes or hours or days (max time 999
days)
If no time is specified then the output will be turned on until the “Turn output Off “ command is
sent
The Output on time XX can also be programmed so when ever the “Turn output On
command is sent the output will turn on for the programmed time
Command:
Set OUTPUT NAME on time to XX (mins or hrs or days)
If everything is fine, the system responds with:
The OUTPUT NAME on time has been set to XX (mins or hrs or days)
If no value is set the system will respond with:
The OUTPUT NAME has been turned on and will stay on because no time-out value
was set
If the text mins or hrs or days does not follow the XX (time) the system will respond with:
Sorry you can only set mins, hrs or days please check the spelling and try again
Change Output to Normally On or Normally Off
Command:
Make OUTPUT NAME inverted
This command is used to define if the output relay is normally open or normally closed.
System default is normally open.
The system responds with:
The
OUTPUT NAME
is now inverted
To non-invert the output:
Command: Make OUTPUT NAME noninverted
The system responds with:
The OUTPUT NAME is now noninverted
Ezy Switch SMS-2 Installation & Operation Manual