background image

9

10

6. User Code (UC)

6-1 The default user code is “1234”. During initial installation, delete the default user
      code, and then set the new user code.
6-2 A total of 6 user codes can be saved.
6-3 The user code can only be used to unlock the door and 
6-4 The user code 
6-5 The user code can be deleted or added at anytime as needed.

7-1 

 The same user code can be reset after being

      deleted.
7-2 The programming code is needed to delete 

8. Delete all user codes

8-1 

 The original user codes can be reset again.

8-2 After deleting all user codes, the automatic lock and the     button lockup
      functions set previously will automatically be disabled. The 

user code

      
8-3 The programming code is required to delete 

9. Temporarily 

user code

9-1 This will temporarily disable all user codes. The automatic lockup and keypad
      lockup functions that were set previously will automatically be disabled. A key
      must be used to lock and unlock the door.
9-2 To restore the code function and other electronic functions, repeat the steps for
      “Temporarily 

 user code”.

10. 

 one-time user code

10-1 After the one-time user code is entered and used, it is 

 and won't be

        able to open the door again.
10-2 The same one-time user code can be set repeatedly.
10-3 The programming code is needed 

to set other functions.

must be 4-10 digits in length.

User codes can be deleted individually.

individual codes.

All user codes can be deleted at once.

door can only be locked

      or unlocked with a key. The original functions will be restored once the 

is set.

all user codes.

disable

 

disable

Create

disabled

for setup.

7. Delete individual user code

11. Restore the default PC & UC

to delete

12. Unlock

a registered

12-2 To unlock with the keypad

1. Place the hand within 2 cm of the keypad or press any key once to light up the

             keypad.

         

 2. 4 numbers will appear on the keypad.

 

Press them in any order.

        

  3. Enter the user code.

  

13. Lock

The door can be locked from

the inside

14. Automatic lockup

14-1 The timer (10-99 seconds) of automatic lockup can be set up by the user as
        needed. (The default timer is 30 seconds after the system is unlocked.)
14-2 To disable the automatic lockup, please repeat the steps for “Automatic lockup”.

15. Code protection

If the user code is entered incorrectly over 5 times, the system will initiate the
protective function and disable the keypad for 45 seconds.

16. Backlight

When the hand is within 2 cm of the keypad, the backlight will light up for about 5
seconds, making it easy to operate lockset in the dark.

 

         

Use this function when forgetting the programming code or 

 all settings.

12-1 The door can be unlocked by entering 

 user code or the key from

        outside, or pressing the lever down / turning the knob from inside.

        

4. Press the     button.

             When the light for the key goes out, the system is unlocked.

When the keypad lights up, the user may press the keypad, press     button or use
the key and automatic lockup function to lock the door. 

 by turning the interior turn-piece.

 

Содержание PT2Q0S10

Страница 1: ...nd unauthorized modification 3 Limited of Liability The manufacturer will not be held liable for incidental or consequential losses or damages to any act of God 4 Reminder Service requirement shall su...

Страница 2: ...g P 14 Indentifying the door handing Power supply Low battery indication Keypad light indication Audio indication Programming Code PC User Code UC Delete individual user code Delete all user codes at...

Страница 3: ...ase switch the levers by following steps Installation Instructions a The illustration shows a backset of b Pull the cam all the way to the right to adjust backset to 2 3 4 70mm c To restore back to 2...

Страница 4: ...of strike outline Then use the chisel to scrape out the door frame for 1 16 1 6mm deep within the traced outline Make sure to chisel deep enough to allow the strike to lay flush with the frame surfac...

Страница 5: ...ews or self tapping screws may be used if needed Wood screws are used for wooden doors and self tapping screws are used for metal doors to increase bonding Interior plate Cable Cable Fasten screws Woo...

Страница 6: ...code and is 5 3 The programming code cannot be used to unlock the door 5 4 The programming code 5 5 The programming code can be changed anytime as needed DC6V 4 AA 1 5V Alkaline batteries not included...

Страница 7: ...ll user codes can be deleted at once door can only be locked or unlocked with a key The original functions will be restored once the is set all user codes disable disable Create disabled for setup 7 D...

Страница 8: ...lar zinc carbon batteries and avoid mixing batteries of different brands 3 Do not use any chemicals or add any lubricants when cleaning the lock to avoid damaging the panel and coating Function setup...

Страница 9: ...manually with the key To restore user code functions please repeat the setup process for Temporarily user code disabled disabled disable Enter new UC Restore factory default Instruction After removin...

Отзывы: