Measuring Capacitance (DM-332)
Figure 5-9. Measuring Capacitance
APPLICATIONS
MEASURING CAPACITANCE
C
C
K
K
A
A
L
L
B
B
D
D
R
R
E
E
0.000
Turn off the power and discharge the capacitor before
attempting a capacitance measurement. For measuring
capacitor turn rotary switch to CAP and connect the test
leads to the capacitor.
For capacitors less than 10
or in noisy environments,
use short test leads or a test fixture.
NOTE
Capacitor should be discharged before being tested.
When testing large capacitors, note that there will be a
certain time lag before displaying final indication.
The measurement value of capacitor subtract normal
reading value from measurement reading value.