4.4. 

Position the closure elbow attached to the stair top post so it is aligned with the closure elbow 
attached to the platform handrail post (but do not tighten fully) then measure the distance 
between the two larger round faces. The gap between the upper and lower closure elbows 
should be the same but it is advisable to check both before cutting the tubes to fit (FIG.14). 

 

FIG. 14 

4.5. 

Cut the 1-

1/2″ diameter round tubes to fit the gap measured in the previous step. 

4.6. 

Using a metal file, smooth all sharp edges from cutting the round tubes. 

4.7. 

Disassemble the closure elbows by removing the elbow screws and nuts but do not remove 
the closure elbows halves from the platform handrail or stair top posts (FIG. 15). 

4.8. 

Install an elbow half into each end of the cut tube until fully engaged. 

4.9. 

Tighten internal set screws with a T-Handle wrench. An Allen wrench and pliers to get 
additional torque can be used as an alternate (FIG. 15). 

4.10. 

Reassemble all elbows by replacing center insert and securing with the screw and nut then 
tighten all fasteners, including the hex cap screws, securely (FIG. 15). 

4.11. 

Test to ensure all elbows are properly secured and attached. If needed, tighten internal set 
screws to secure more rigidly. 

Содержание Pathway MSTAIR2839

Страница 1: ...at www ezaccess com warranty satisfaction EZ ACCESS a division of Homecare Products Inc All rights reserved All text and images contained in this document are proprietary and may not be shared modifie...

Страница 2: ...city Read and follow all instructions labels and warnings prior to assembly and use Fill out and return warranty registration TOOLS TYPICALLY REQUIRED Ratchet with 1 2 deep well socket or 1 2 wrench 1...

Страница 3: ...omponents supplied or approved by manufacturer with stair system Do not sit stand or climb on guards or handrails Do not use handrails or any other part of the stair system to support planters decorat...

Страница 4: ...handrail tubes and tube connectors WARNING Do not use a stair at a height higher than its intended use When connected to a platform in the Pathway Modular Ramp System the stair will commonly be used w...

Страница 5: ...n ridges oriented upward Use a rubber mallet if needed to tap the tread into the tread channel cleat until the holes in the cleat line up with the holes in the stair tread FIG 1 FIG 1 2 2 Install 5 16...

Страница 6: ...or 1 2 wrench Tighten nuts until the channel cleat clamps onto the tread slightly NOTE Some deformation in the channel cleat by the carriage bolt is normal 3 ASSEMBLING THE STAIR LEGS HANDRIALS 3 1 I...

Страница 7: ...r the riser has been positioned and leveled tighten all set screws in the corner pockets for stair top posts and legs securely FIG 6 FIG 6 3 4 Make sure the stair assembly is positioned flush against...

Страница 8: ...MHRPSC kit is used the closure elbows assemblies used in this kit must be installed in the stair top posts before proceeding with the rest of the stair handrail installation Complete step 4 1 and 4 2...

Страница 9: ...ach tube Make sure the elbow side for the assembly screw is oriented in the same direction and the flat portions of the elbow halves are parallel on both ends of the handrail tube then tighten the int...

Страница 10: ...cket cap screws but do not tighten fully FIG 10 3 10 Adjust stair bottom posts up or down until the handrails are parallel to the stair side rail then tighten the 3 8 16 set screws in the bottom corne...

Страница 11: ...n Step 4 1 The elbow assembly screw should be on top and the elbow half which will be installed into the 1 1 2 diameter round tube must be oriented toward the platform handrail post where the connecto...

Страница 12: ...es from cutting the round tubes 4 7 Disassemble the closure elbows by removing the elbow screws and nuts but do not remove the closure elbows halves from the platform handrail or stair top posts FIG 1...

Страница 13: ...13 FIG 15 4 12 Double check that all fasteners are tightened securely Periodically check for ground shifts and regularly check and tighten hardware as needed...

Страница 14: ...the nearest whole year YEARS 0 1 Unit repaired or replaced YEARS 1 2 Repair or 50 credit current purchase price multiplied by credit percentage YEARS 2 3 Repair or 25 credit current purchase price mul...

Отзывы: