- 54 -
eyeheight
Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH
Reg. No. 2855535 Telephone: +44 (0) 1923 256 000 Fax: +44 (0) 1923 256 100 email: [email protected]
Menu 112-115: UTILITY MENUS - 2
Menu
Num.
Heading
Automation
Function
112
LOG
none
Go to the Log menu (128-131)
113
POM
none
Go to the Power on Memory and
Reset (144-147)
114
TIME CODES
none
Go to the Time Code Menus (116-
119)
115
BACK
none
Go to the Setup menus (8-11)
Menu 116-119: TIME CODE MENUS
Menu Num.
Heading
Automation
Function
116
ATC Mode LTC
VITC1
VITC2
[0
Æ
2]
This selects the time code packet
type for ATC time codes. ATC
packets have source information
which indicates the origin of the time
code. LTC, VITC1 or VITC2.
117
Time
Code
ATC
LTC
AUTO
[0
Æ
2]
This selects ATC or LTC time codes.
In AUTO mode the type of time code
is selected automatically based on
the time code received.
118
VITC LINE
NUMBER
(SD Only)
L1
[1
Æ
312]
L2
[1
Æ
312]
This selects the two line numbers
that contain the VITC. Only
applicable in Standard Definition.
PAL Field 1: Lines 19, 21
NTSC Field 1: Lines 14, 16
119
BACK
none
Go to the Composite Clip and Knee
menus (112-115)
ATC
Mode
=VITC1
Time
Code
=VITC
VITCLn
L1=19
L2=21