www.eyc-tech.com 

 

11

 

13  NC

NC 

14  Cond2

Conductivity electrode white wire 

15  NC

NC 

16  T/NTC

NTC 10 K temperature resistance interface1 

17  T/NTC

NTC 10 K temperature resistance interface 2 

18  T/P

Pt1000 temperature resistance interface1 

19  T/P

Pt1000 temperature resistance interface2 

20  Cond-ma(+)

Conductivity current output positive end 

21  Cond-ma(-)

Conductivity current output negative end 

22  T-ma(+)

Temperature current output positive end / RS-485 A connector 

23  T-ma(-)

Temperature current output negative end 

24  NC

NC / RS-485 B connector 

Note

This instrument supports two groups of 4 ... 20 mA or one group of 4 ... 20 

mA and one group of RS-485

 

AC

AC 100 ... 240 V+10% 50 / 60 hz

DC

  12 ... 24 V

Power

5 W

 

Relay

Withstand voltage AC 240 V, Maximum current 0.5 A

 

Output current

500 Ω maximum resistance

 

 

 

 

08 

— N 

05 

— +24 V 

 

10 

— L 

06 

— GND 

 

 

01 

— REL1 

17 

— T / P Red line(Temperature) 

 

02 

— REL1 

16 

— T / P Yellow line(Temperature) 

 

 

11 

— Cond1 Blue line 

 

Control alarm wring 

14 

— Cond2 White line 

 

 

Sensor(Electrode) wiring 

 

 

 

20 

 

 

21 

 

 

20 

 

 

21 

RS-485 wiring(optional) 

 

Current output wring 

 

 

AC 220 V Input 

DC 24 V Input 

Alarm device 

AC 220 V 
Power Supply 

Cond current output 

RS-485 output 

Temperature current output 

22 

— A+ 

22 

— GND 

24 

— B- 

 

Содержание DPME02

Страница 1: ......

Страница 2: ...ase read this manual carefully before installation to avoid safety problems and instrument damage caused by wrong records 2 Please avoid high temperature high humidity and corrosive environment to ins...

Страница 3: ...cal wiring 9 3 1 Back panel wiring diagram 9 3 2 Back contact function diagram 10 3 3 Backplane terminal contact description 10 IV Panel introduction 12 4 1 Panel introduction 12 4 2 Key description 1...

Страница 4: ...emperature or one set of 4 20 mA one set of RS 485 6 Using isolation technology strong anti interference ability 7 The high and low points of the two sets of relays can be switched freely and the hyst...

Страница 5: ...are holes on the panel of the distribution box The transmitter is placed directly from the panel of the distribution box Put the holder attached to the transmitter from the rear and snap it into the f...

Страница 6: ...installation methods Installation of sensors is a very careful work please install sensors must carefully select the installation site deliberate installation methods so as to avoid the measurement da...

Страница 7: ...Wrong installation B correctly installed 2 The installation mode of A will lead to the formation of the air cavity in the conductivity cell resulting in measurement errors and instability and should b...

Страница 8: ...cable of the electrode is standard length and special cable before leave the factory When the measuring cable needs to be lengthened please make an agreement with the manufacturer before supply 5 Plea...

Страница 9: ...trical wiring 3 1 Back panel wiring diagram 01 REL1 02 REL1 03 REL2 04 REL2 05 24V 06 GND 07 NC 08 N 09 NC 10 L S N 0149316250013 Cond1 11 NC 12 T P 18 T P 17 16 15 14 13 NC Cond2 T NTC T NTC 20 21 22...

Страница 10: ...rm control external relay 04 REL3 Second alarm control external relay 05 DC DC 24 V output 06 GND DC DC 24 V output 07 NC NC 08 AC AC power supply 220 V N 09 NC NC 10 AC AC power supply 220 V L 11 Con...

Страница 11: ...rent output negative end 24 NC NC RS 485 B connector Note This instrument supports two groups of 4 20 mA or one group of 4 20 mA and one group of RS 485 AC AC 100 240 V 10 50 60 hz DC 12 24 V Power 5...

Страница 12: ...function description is as follows Trigger the setting interface in the measurement mode return to the previous menu under the setting interface Switching and numerical adjustment of menus under the...

Страница 13: ...elay 2 the high displays the red light the low displays the green light The figure above shows the display interface of system information and alarm information respectively System information All set...

Страница 14: ...The main menu includes four first level menus 1 System setting The system setting parameters of the instrument include language password date backlight etc 2 Sensor setting Includes display mode cali...

Страница 15: ...ll be four prompts ESC OK NO and ENT at the bottom of the screen corresponding to the four buttons of the meter The user needs to reconfirm whether the parameter is correctly selected If yes press the...

Страница 16: ...can set the corresponding backlight time according to the demand The screen will darken when the meter reaches backlight time 5 2 Sensor setting Menu 2 1 Display mode This instrument supports 6 displa...

Страница 17: ...corresponding measuring range are as follows Coefficient 0 01 0 05 200 0 s cm Coefficient 0 1 0 1 2000 s cm Coefficient 1 0 1 0 20 00 ms cm Coefficient 10 0 10 200 ms cm The user must determine the e...

Страница 18: ...t display mode 2 4 6 MTF F Manual mode Fahrenheit display mode Menu 2 5 Temperature settings The temperature adjustment is divided into two parts the upper part is the temperature adjustment value and...

Страница 19: ...ude relay 1 relay 2 and two 4 20 mA settings of which two 4 20 mA correspond to the measured values of temperature The following takes the relay 1 and 4 20 mA of dissolved oxygen as an example Menu 3...

Страница 20: ...action diagram is as follows Menu 3 2 Relay 2 The setting of relay 2 is the same as the setting principle of relay 1 please refer to the setting of relay 1 Menu 3 3 Electric current This menu is divid...

Страница 21: ...er can freely set the current 1 20 mA setting value After pressing Enter the system will automatically save the settings Note The conductivity value and current value set in 4 20 mA correspond to each...

Страница 22: ...Electric current 1 20 mA correction The setting principle of 20 mA is the same as that of 4 mA Please refer to 4 mA for correction Menu 3 4 Electric current 2 The setting principle of current 2 is th...

Страница 23: ...e coefficient of the electrode as 1 0 coefficient dips the electrode into the correction liquid such as 1413 s cm Adjust the value of the electrode coefficient by button such as adjusting the coeffici...

Страница 24: ...tion 0 0 00 0 C 25 0 C High alert trigger value 0 00 20 00 s cm 15 00 s cm High alert hysteresis value 0 00 20 00 s cm 1 00 s cm Low alert trigger value 0 00 20 00 s cm 5 00 s cm Low alert hysteresis...

Страница 25: ...es for Power Supply 3 Reading errors A The constant is set incorrectly B Changes in electrode constants C Measuring the rate of flow is too fast or dead water A Resetting Constants B Replacement of ne...

Страница 26: ...www eyc tech com 26...

Отзывы: