![extronics iWAP XN3 X2000 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/extronics/iwap-xn3-x2000/iwap-xn3-x2000_installation-and-operating-manual_2457414025.webp)
XN3 Installation and Operating Manual
25
7
Marking information
7.1.1
ATEX/IECEx
•
Um = 60Vdc or 253Vac depending on customer specification.
•
Alternative ambient temperature ranges may be specified depending on the service
temperature of installed equipment.
•
Alternative coding when Extronics iSOLATE501 is installed for DC isolation:
A
II 3 (1) G Ex ec [ia Ga] nR IIC T6 Gc
D Ex [ia Da] tc IIIC T85°C Dc
•
Alternative coding for configurations with no RF output:
A
II 3 G Ex ec nR IIC T6 Gc
D Ex tc IIIC T85°C Dc
Содержание iWAP XN3 X2000
Страница 1: ...INSTALLATION AND OPERATING MANUAL ...
Страница 11: ...XN3 Installation and Operating Manual 11 Figure 1 Aluminium Enclosure Mounting Dimensions ...
Страница 24: ...XN3 Installation and Operating Manual 24 6 Technical Data ...
Страница 28: ...XN3 Installation and Operating Manual 28 9 EU Declaration of Conformity ...
Страница 29: ...XN3 Installation and Operating Manual 29 ...