3.10
Intrinsically Safe RF Outputs
Refer to Figure 9 for location of Intrinsically Safe RF outputs.
3.10.1
Example of RF threshold power calculation
The following example shows how the RF threshold power may be calculated:
Maximum transmitter output power (from transmitter datasheet) = 20dBm
(100mW)
Coaxial cable loss = 2dB
Antenna gain = 5dBi
Threshold power = 20dBm
–
2dB + 5dBi
Threshold power = 23dBm (200mW)
Standard configuration
Remote mounting
Non-hazardous area
Top mount antenna
Bottom mount antenna
Intrinsically
safe outputs.
Minimum IP54
connection