5
100-240V~50/60 Hz
1.1A MAX
INPUT
OUTPUT
POWERED TLP
LAN
To Network or
XTP Device
To a TLP Pro
touchpanel
Extron PI 140
Figure 6.
Connecting the Power Injector
from the switch or router to the power supply input.
2.
Connect a second straight-through cable from the power injector to the TLP
Pro touchpanel XTP/LAN/PoE connector (see
,
cable carries the network information and 48 VDC from the power injector to
the touchpanel.
3.
Connect the IEC power cord to a convenient 100 VAC to 240 VAC, 50-60 Hz
power source.
Alternatively, use an Ethernet cable to connect the XTP/LAN/PoE port of the interface to a PoE+ switch or connect the touchpanel
directly to an XTP model that is capable of remotely powering a touchpanel (see the
Reset Modes: a Brief Summary
The TLP Pro 1220TG, TLP Pro 1520TG, and TLP Pro 1720TG offer the following reset modes. For full information about the modes,
see the
TLP Pro 1220, TLP Pro 1520, and TLP Pro 1720 Series User Guide
.
•
Use factory firmware:
Press and hold the
Reset
) while applying power to the unit. Use this mode
to replace firmware in the event of firmware failure.
•
Reset All IP Settings:
Press and hold the
Reset
button for 6 seconds. After the Reset LED (
) blinks twice, release
and momentarily press the
Reset
button. Use this mode to reset all network settings without
affecting user-loaded files.
•
Reset to Factory Defaults:
Press and hold the
Reset
button for 9 seconds. After the Reset LED blinks three times, release
and momentarily press the
Reset
button. Use this mode to return the interface to factory
default settings.
NOTES:
•
The factory configured passwords for all accounts on this device have been set to the
device serial number. Passwords can be changed during configuration. Passwords are
case sensitive.
•
If the device is reset to default settings, the passwords are reset to the default
password, which is
extron
(for either
admin
or
user
).
•
Enable or Disable the
DHCP Client
Use this mode to toggle between DHCP enabled and DHCP disabled. Press the
Reset
button
five times, consecutively. After the fifth press, do not press the button again within 3 seconds.
If DHCP was enabled, it is now disabled and the Reset LED blinks three times. If DHCP was
disabled, it is now enabled and the Reset LED blinks six times.
Reset Modes
Connecting Power
ATTENTION:
•
The touchpanels can use a 12 VDC desktop power supply or Power over Ethernet. Do not connect either power supply
before reading the Attention in the Power section of the
TLP Pro 1220, TLP Pro 1520, and TLP Pro 1720 Series User Guide
.
•
Les écrans tactiles peuvent utiliser une source d’alimentation externe 12 Vcc ou l’alimentation POE via Ethernet. Ne
branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section « Power Supply » du
TLP Pro 1220, TLP Pro 1520, and TLP Pro 1720 Series User Guide
.
The Extron PI 140 power injector is included with the TLP Pro 1720MG. For the TLP Pro 1220MG or TLP Pro 1520MG, a 12 VDC
power supply or a power injector must be purchased separately. Figure 6 shows the Extron PI 140. Your power injector may look
different.
1.
Connect a straight-through Ethernet cable from the power injector to a switch or router. This cable carries network information