Extron electronics TouchLink TLP Pro 1020 Series Скачать руководство пользователя страница 9

Application Diagram

The application diagram below shows the TLP Pro 720M. The other touchpanels in this user 
guide can be used in similar configurations.

0.5A MAX

POWER

12V

1

Tx Rx

1

2 3 4 +V

1

2 3 4 G

RS-232   AUTO

CONTACT

TALLY OUT

SW4 HDMI

2

3

4

INPUTS

OUTPUT

REMOTE

INPUT

S/PDIF

ANALOG

HAE 100

OUTPUTS

AUDIO

FORMAT

HDMI OUTPUT AUDIO

L

R

ON

OFF

EDID

STORE

12V         
0.4A MAX

HDMI

POWER

HDMI

ON

1 2

POWER

12V         

0.7A MAX

L

R

L

8Ω / 4Ω

CLASS 2
WIRING

R

10V

V C G

50mA

L

MPA 152 Plus

R

INPUTS

OUTPUTS

REMOTE

POWER

12V         

--A MAX

G

Tx Rx

RTS CTS

COM 1

G

Tx Rx

COM 2

V C G

VOL

RELAYS

1   2   C

1   2   3   4   G

DIGITAL I/O

PWR  OUT  =   6W

eBUS

+V +S -S G

LAN

IPCP PRO 250

IR/S

S   G

STANDBY/ON

PQLS

HDMI

OPEN/CLOSE

FL OFF

USB

!

1

@

2

#

3

$

4

%

5

^

6

&

7

*

8

(

9

)

0

_
-

+

=

|

\

}

]

{

[

~

`

Q

W

E

R

T

Y

U

I

O

P

:

;

<

,

>

.

?

/

A

S

D

F

G

H

J

Z

X

C

V

B

N

M

K

L

control

shift

caps lock

tab

esc

F1

F2

F3

F4

F5

F6 

F7

F8

F9

F10

F11

F12

F13

F14

F15

F16

F17

F18

F19

alt

option

command

delete

fn

home

clear

enter

=

/

*

8

-

5

2

7

0

.

4

1

+

9

6

3

page
up

page
down

end

delete

command

option

control

shift

return

MODEL 80

FLAT PANEL

WiFi

1 2 3 4

Extron

TLP Pro 720M

7" Wall Mount 

TouchLink Pro 

Touchpanel

Blu-ray 

Player

PC

Extron

MPA 152 Plus

Power Amplifier

Extron

HAE 100

HDMI Audio De-Embedder

Extron

SW4 HDMI

Switcher

Extron

SM 3

Full-Range Speakers

TCP/IP

Network

Satellite 

Receiver

Laptop

Extron 

IPCP Pro 250

IP Link Pro 

Control Processor

Shade 

Control

Flat Panel Display

Motion 

Sensor

Ethernet/PoE

Ethernet

Digital Input

Relay

RS-232

RS-232

HDMI

HDMI

HDMI

Volume Control

HDMI

HDMI

HDMI

Audio

IR

PUSH

PUSH

POWER

GUIDE

MENU

RES

480

480p 720p 1080i 1080p

DIREC

TV

HD

SELECT

D I R E C T V

Extron

Help

System

Off

Display

Room

Control

Off

Mute

Screen

Lighting

December 15, 2013 - 7:58 AM

Audio

Control

Volume

Mute

Tuner     

1 2 3

VCR

Laptop

PC

DVD

Doc

Cam

Tuner

On

Channel

Last

Presets

More

Presets

3

2

1

6

5

4

9

8

7

Enter

0

Figure 1. 

Application Diagram

 

TLP Pro 720 Series and TLP Pro 1020 Series • Introduction

3

Содержание TouchLink TLP Pro 1020 Series

Страница 1: ...68 2405 01 Rev A 08 14 TLP Pro 720 Series and TLP Pro 1020 Series User Guide TouchLink TouchLink Pro Touchpanel Control Systems...

Страница 2: ...Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol I auf dem Produkt soll dem Be...

Страница 3: ...ics All rights reserved Trademarks All trademarks mentioned in this guide are the properties of their respective owners The following registered trademarks registered service marks SM and trademarks T...

Страница 4: ...X1 X2 X2 X2 CE NOTE For commands and examples of computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer respon...

Страница 5: ...Designer and Global Configurator 21 Using the Software 22 TLP Pro 720 Series and TLP Pro 1020 Series Web Pages 22 Updating the Firmware 23 Downloading Firmware 23 Updating Firmware Using the Touchpan...

Страница 6: ...TLP Pro 720 Series and TLP Pro 1020 Series Contents vi...

Страница 7: ...f 1024x600 z z TLP Pro 1020M is a wall mount touchpanel z z TLP Pro 1020T is a tabletop touchpanel A range of mounting options are available see Mounting on page 23 The screen layout is designed with...

Страница 8: ...otion detector wakes touchpanel Mounting options for tilt models TLP Pro 720T or TLP Pro 1020T z z Sit on a tabletop weighted base allows up to 45 of tilt z z Threaded holes in baseplate allow for sec...

Страница 9: ...F16 F17 F18 F19 alt option command delete fn home clear enter 8 5 2 7 0 4 1 9 6 3 page up page down end delete command option control shift return MODEL 80 FLAT PANEL WiFi 1 2 3 4 Extron TLP Pro 720M...

Страница 10: ...source d alimentation 12 VCC ou page 12 injecteur PoE Mount the units There are several mounting options for TouchLink Pro touchpanels see Mounting on page 23 Connect cables to the touchpanels See TLP...

Страница 11: ...Panel Features TLP Pro 720 Series and TLP Pro 1020 Series Front Panel Features Extron B C A E F D B C A E D A A C B A E D B A E F D C A A F F C C TLP Pro 720M TLP Pro 1020M TLP Pro 720T TLP Pro 1020T...

Страница 12: ...ure 3 TLP PRO 720M Top View D Ambient light sensor monitors ambient light level and adjusts screen brightness based on the settings configured using the setup menu see page 14 E LCD screen has a 800x4...

Страница 13: ...Bezel Removed A Bezel attachment points The TLP Pro 720M has eight attachment points two on each side two on the top edge and two on the bottom edge The TLP Pro 1020M has ten attachment points three...

Страница 14: ...ts I T E 1T23 TLP Pro 720T A LAN PoE POWER 12 V 1 0 A MAX 33 2453 01 A N15779 Patent s www extron com patents I T E 1T23 TLP Pro 1020T Figure 5 TLP Pro 720 Series and TLP Pro 1020 Series Rear Panels A...

Страница 15: ...rdons d alimentation doivent tre tenus l cart l un de l autre quand l alimentation est branch e Couper l alimentation avant de faire l installation lectrique CAUTION Risk of Explosion if battery is re...

Страница 16: ...es d a ration ou dans les cavit s murales La source d alimentation doit tre situ e proximit de l quipement de traitement audiovisuel dans un endroit ordinaire avec un degr 2 de pollution fix un quipem...

Страница 17: ...ns tactiles peuvent utiliser une source d alimentation externe 12 Vcc et sont galement compatible avec l alimentation POE via Ethernet PoE 802 3af classe 3 Ne branchez pas de sources d alimentation ex...

Страница 18: ...cation de conformit r glementaire Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicin...

Страница 19: ...initiates one of three reset modes for the unit see Reset Modes on page 30 E Reset LED see figure 5 indicates power status and reset status of the device see Reset Modes on page 30 F VESA mounting hol...

Страница 20: ...u screens In this section the figures will show the screens for the TLP Pro 720M The screens for the other touchpanels are similar Status Screen Status Display Audio Advanced Exit Network Info Model T...

Страница 21: ...P addresses are assigned by DHCP press On The selected button is highlighted in yellow If DHCP is selected you will only be able to set the Host Name and the DNS IP address All other values are set by...

Страница 22: ...example 892 you are able to enter the 89 but the 2 cannot be entered Click Back to delete the last digit If no value has been entered for the selected octet pressing Back moves the cursor back to the...

Страница 23: ...page 5 z z LCD Brightness allows you to adjust the screen brightness using the slider control z z Wake on Motion activates the panel from Sleep mode when motion is detected near the unit Toggle betwe...

Страница 24: ...ion about the system the Global Configurator Project and the GUI Designer Project Menu PIN The PIN setup options allow you to enable disable or change the setup menu PIN The PIN is a 4 digit number Ea...

Страница 25: ...he Menu button is located on the front panel and the bezel must be removed first see figure 4 B on page 7 2 Release the button The calibration screen opens to show cross hairs 3 Follow the on screen i...

Страница 26: ...ce After assigning the control functions the project is rebuilt and uploaded to the control processor and touchpanel The GUI Designer and the Global Configurator Plus and Global Configurator Professio...

Страница 27: ...ens asking for your user name and password By default the user name is admin and the password is extron both user name and password are all lower case The single page provides general and network info...

Страница 28: ...ation about the program 7 Click Download 8 Follow the onscreen instructions to download the program Make a note of where the firmware is stored on the PC Updating Firmware Using the Touchpanel Web Pag...

Страница 29: ...the equipment gets adequate air flow for safe operation Mechanical loading Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition Circuit overloading C...

Страница 30: ...h with the unit and check that the touchpanel can fit into the hole If necessary use a rasp or a coarse file to enlarge the hole 4 Run the network and video cables inside the wall to the hole leaving...

Страница 31: ...using the templates provided mark the lectern and cut a hole z z TLP Pro 720M 7 5 inches 19 05 cm wide x 5 81 inches 14 76 cm high z z TLP Pro 1020M 10 06 inches 25 55 cm wide x 6 98 inches 17 73 cm...

Страница 32: ...Pro 720T and TLP Pro 1020T Desktop Mounting Placement without a Mounting Kit Both the TLP Pro 720T and TLP Pro 1020T have stands that allow them to be placed on a desktop Both units can be secured to...

Страница 33: ...the lock SMA 1 swivel mount adapter Both touchpanels can also be mounted with the optional Extron SMA 1 swivel mount adapter which allows them to be mounted permanently and swivel up to 180 in either...

Страница 34: ...late and locking nut as described in the SMA 1 Swivel Mount Adapter Kit User Guide VESA Mounting Removing the base 1 Remove the back cover and base cover using the Extron removal tool as described in...

Страница 35: ...ary connect the cables and use a zip tie to secure them to the back of the touchpanel 2 Secure a VESA D 75 mm mount kit to the back of the touchpanel Follow the instructions provided with the mounting...

Страница 36: ...e mode and the LED flashes quickly 3 Upload new firmware to the unit as desired see Updating the Firmware on page 22 NOTE After a User Factory Firmware reset is performed update the touchpanel firmwar...

Страница 37: ...ay address to the factory default 0 0 0 0 z z Sets all other IP settings addresses and domain and host names back to factory default z z Turns DHCP off Purpose and Notes Reset All IP Settings mode ena...

Страница 38: ...ed in the TLP Pro Touchpanel Models Package License Package License aufs2 util GPL v2 avahi LGPL v2 1 bstrlib BSD busybox GPL v2 bzip2 BSD can utils GPL v2 cjson MIT devmem2 GPL v2 expat MIT gi fcgi g...

Страница 39: ...ron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 or 800 633 9876 Europe 31 33 453 4040 Asia 65 6383 4400 Japan 8...

Отзывы: