Figure 2. 

TLP Pro 525M Mounting Plate (left) and TLP Pro 725M and 1025M Mounting Plate (right)

NOTE: 

The TLP Pro 725M and TLP Pro 1025M series touchpanels use the same mounting plate.

Without a wall box

If the wall box is not required by local building codes, you can mount the touchpanel directly into drywall. 

1. 

Use the mounting plate as a template to mark the wall or download the cut-out template for your product from 

www.extron.com

Place the template or mounting plate against the wall or furniture in a suitable location and ensure that it is level. 

2. 

Mark the position of the hole and cut the wall.

• 

For the TLP Pro 525M, this hole is 2.4 inches (61 mm) wide x 2.1 inches (53 mm) high.

• 

For the TLP Pro 725M or 1025M, this hole is 3.5 inches (89 mm) wide x 2.0 inches (51 mm) high.

3. 

Mark the slots labeled 

WALL

 (TLP Pro 525M) or 

MK

 (TLP Pro 725M or TLP Pro 1025M) (figure 2) and drill the two pilot holes. Extron 

recommends using two Molly bolts or SnapToggle bolts.

4. 

Secure the mounting plate to the wall (see 

figure 1

2

, on the previous page).

5. 

Complete the installation as described in 

steps 3 through 6

 on the previous page.

Front Panel Features

Figure 3 shows the front panel of the TLP Pro 725M. The front panels of all the touchpanels have the same features and are almost 
identical apart from the size. 

figure 2

A

A B

B

C

C A

A

D

D

E

E

E

E

Figure 3. 

TLP Pro 725M Front Panel

A

 

Motion sensor

 — Detects motion between three to five feet 

from the touchpanel, and at least 15° from the center axis.

• 

When no motion has been detected for a user-defined 
period of time, the touchpanel enters sleep mode.

• 

When motion is detected by the sensor, the screen 
display is restored and active.

B

 

Communication LED

 — Shows the configuration and 

connection status of the touchpanel:

• 

Unlit during normal operation (the touchpanel is 
configured and connected to an IP Link Pro control 
processor).

• 

Blinks red if the touchpanel has been configured but is 
not connected to an IP Link Pro control processor.

• 

Lit solidly red if the touchpanel has not been 
configured.

The indicator can be toggled between enabled and disabled, using the 

Setup Menu

 (see the next page). 

C

 

Light sensor

 — Monitors ambient light level and adjusts screen brightness.

D

 

Capacitive touchscreen

• 

The TLP Pro 525M series has a 5-inch screen with a 800x480 resolution.

• 

The TLP Pro 725M series has a 7-inch screen with a 1024x600 resolution.

• 

The TLP Pro 1025M series has a 10.1-inch screen with a 1280x800 resolution

E

 

Status lights

 — Two LED light bars, one on either side of the screen, which can be programmed to provide system feedback.

• 

Light red or green

• 

Blink or stay continuously lit

For information about programming these LEDs, see the 

Global Configurator Help File

 and 

Global Scripter Help File

.

Содержание TLP Pro 525M seriesl

Страница 1: ... DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either admin or user Password By default this is extron for either admin or user Make a note of the touchpanel MAC address Mount and Cable All Devices ATTENTION Do not power on the touchpanels or control processors until you have read the Attention in the Rear Panel Features section of t...

Страница 2: ...he TLP Pro 725M and 1025M touchpanels mount to a 2 gang junction box Extron provides four 3 4 6 32 Philips pan head screws for mounting to US junction boxes Extron provides two 16 mm M 3 5 Philips pan head screws for mounting to MK junction boxes EU junction boxes are usually provided with their own screws With a wall box 1 Install a junction box or wall box see figure 1 1 following the instructio...

Страница 3: ...TLP Pro 725M The front panels of all the touchpanels have the same features and are almost identical apart from the size A A B B C C A A D D E E E E Figure 3 TLP Pro 725M Front Panel A Motion sensor Detects motion between three to five feet from the touchpanel and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode Wh...

Страница 4: ...D D D D K K D D D D I I J J TLP Pro 1025M Figure 4 TLP Pro 525M 725M and 1025M Rear Panels NOTE The panels shown in figure 4 are for illustration only and are not to the same scale For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mou...

Страница 5: ...025 Series User Guide Le TLP Pro 525M le TLP Pro 725M et le TLP Pro 1025M supportent l alimentation via Ethernet PoE 802 3af classe 3 Veuillez lire la partie Attention dans la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These touchpanels are shipped without a power injector The power injector must be purchased sepa...

Страница 6: ...efaults Press and hold the Reset button for 9 seconds After the Reset LED flashes three times release and momentarily press the Reset button Use this mode to return the touchpanel to factory default settings Status Display Audio Advanced Exit Network Info Model TLP Pro 725M Part Number 60 1563 02 Firmware Version 1 02 0001 b001 Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Dis...

Отзывы: