ATTENTION:
•
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code
part 1, section 16.
•
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical Code,
partie 1, section 16.
•
The power supply shall not be permanently fixed to the building structure or similar
structure.
•
La source d’alimentation ne devra pas être fixée de façon permanente à une structure
de bâtiment ou à une structure similaire.
An Extron IPL Pro control processor must also be connected to the same network domain as the
TouchLink Pro touchpanel. See the
for a list of suggested models.
The network port has two LEDs. The green LED lights steadily to indicate that the touchpanel is
connected correctly to a network. The yellow LED flashes to indicate that data is being passed to
or from the touchpanel.
E
(4)
on page 18).
F
(TLP Pro 1022T only) — can be programmed to provide system feedback.
•
Light red or green
•
Blink or solidly lit
For information about programming this light, see the
Global Configurator Help File
.
G
(4)
(TLP Pro 1022T only)— for use with the Extron LPVM-1 (see
H
(TLP Pro 1022T only)— Secure the base to the touchpanel.
For VESA mounting, remove the base by unscrewing the hinges (see
on
page 22).
TLP Pro 1022 Series • Panel Features
7