Содержание PowerCage FOX 4G Rx DVI

Страница 1: ...68 1191 01 Rev A 06 10 High Resolution Fiber Optic Transmitters and Receivers PowerCage FOX 4G Tx Rx DVI PowerCage FOX 4G Tx Rx VGA User Manual Fiber Optic Extenders...

Страница 2: ...rksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bev...

Страница 3: ...otection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in a...

Страница 4: ...ol 15 Board Remote RS 232 Ports 15 PowerCage Configuration Port 16 Simple Instruction Set Control 16 Host to Unit Instructions 16 Symbol Definitions 17 Unit initiated Messages 18 Error Responses 19 Us...

Страница 5: ...ontains information about the following Extron PowerCage FOX 4G modular board designed fiber optic transmitters and receivers for the PowerCage Modular Power Enclosures PowerCage FOX 4G Tx VGA transmi...

Страница 6: ...oprietary optical signal from the receiver consisting of the RS 232 return from a controlled device PowerCage FOX 4G Rx DVI receiver Accepts a proprietary optical signal on an LC connector from a Powe...

Страница 7: ...fiber optic cable is installed the receiver outputs a proprietary signal on the second fiber optic cable For video resolutions up to 1600 x 1200 or 1080p the receiver s video output is a perfect pixe...

Страница 8: ...mission up to 1600 x 1200 at 60 Hz or 1080p Video input PowerCage FOX 4G VGA The transmitter accepts RGBHV RGBS RGsB or RsGsBs on a 15 pin HD connector PowerCage FOX 4G DVI The transmitter accepts a s...

Страница 9: ...face and drag and drop point and click operation Simple Instruction Set SIS The transmitters and receivers use the SIS for easy remote control operation Audio level The audio output can be set to eith...

Страница 10: ...DVI Tx Rx L R AUDIO PowerCage FOX 4G Rx VGA PowerCage FOX 4G Rx DVI 1 2 REMOTE RS 232 RS 232 OVER FIBER Tx Rx Tx ALARM Rx OUTPUT RGB PowerCage FOX 4G Rx VGA Tx Rx L R AUDIO 1 2 REMOTE RS 232 RS 232 O...

Страница 11: ...Figure 4 Typical Audio Connectors The input audio level can be set via RS 232 control See Remote Control d RS 232 Over Fiber port If you want the transmitter receiver system to RS 232 OVER FIBER Tx Rx...

Страница 12: ...ur transmitter is configured to daisy chain the optical signal system functionality is reduced You will not receive RS 232 reports from the controlled device and some Windows based control program fun...

Страница 13: ...ors From Transmitter or Daisy Chained Receiver Receiver Receiver 8b 8a 8a Tx Rx Tx Rx Figure 6 Daisy Chain Configuration Rx required For all one way video audio and serial communications from the tran...

Страница 14: ...figure 7 to properly wire a captive screw output connector Use the supplied tie wrap to strap the audio cable to the extended tail of the connector Ring Sleeve s Tip Tip Ring Sleeve s Tip Tip Unbalan...

Страница 15: ...red for the single link of DVI D data supported by the PowerCage FOX 4G DVI The analog video pins are not connected All of these unused pins are shaded gray in the figure above DVI signals run at a ve...

Страница 16: ...ive data Signal ground NOTE Cross the Tx and Rx lines once between the source and the target RS 232 OVER FIBER Tx Rx 1 2 REMOTE RS 232 Tx Rx ALARM Figure 9 RS 232 Over Fiber Connector NOTES The length...

Страница 17: ...port item q Repeatedly press the Comm Select button item p as necessary to select the desired board n Power LED 16 locations This LED lights to indicate that power is applied to the board at this loca...

Страница 18: ...ct transmission distance Distances of about 50 feet 15 m are typically not a problem In some cases the unit may be capable of serial communications via RS 232 up to 250 feet 76 m away This port is RS...

Страница 19: ...iguration port connection is made the Remote RS 232 port for that board becomes inactive Only one fiber optic cable transmitter Tx to receiver Rx is required for video audio and serial command transmi...

Страница 20: ...signal ground Sleeve Figure 14 9 pin TRS RS 232 Cable Simple Instruction Set Control Host to Unit Instructions SIS commands consist of one or more characters per field No special characters are requi...

Страница 21: ...rough 255 Y Pixel phase 00 through 31 Y1 Total pixels 255 of default value for selected resolution Y1 Sync frequency xxx xx frequency in kHz H or Hz V Y1 Memory preset number 01 to 30 Y1 Audio gain ad...

Страница 22: ...n it first powers on Vx xx is the firmware version number 70 xxx xx is the connected unit s part number Reconfig The unit sends the Reconfig message whenever the video input signal to the transmitter...

Страница 23: ...nd for this configuration Using the Command Response Tables The command response table begins on the next page Either uppercase or lower case letters are acceptable in the command field except where i...

Страница 24: ...nc polarity 7 Y Horizontal shift Set a horizontal position Y H HphY Set horizontal centering to Y Increment position H HphY Shift the image one pixel to the right Decrement position H HphY Shift the i...

Страница 25: ...ommand code is a comma Audio input gain and attenuation NOTES The set gain G and set attenuation g commands are case sensitive The increment level decrement level and show level are not case sensitive...

Страница 26: ...t the receiver to output the grayscale test pattern Output alternating pixels 3J Tst3 Set the receiver to output the alternating pixels test pattern Turn test pattern off 0J Tst4 Set the receiver to o...

Страница 27: ...1 23 sample value only Request part number N 60 nnn nn See Part Numbers Request part number of other unit 1N 60 nnn nn See Part Numbers Show link 1 status 1S Y1 Light status on transmitter Tx to recei...

Страница 28: ...t does not self start run Launch exe from the DVD Click the Software tab scroll to the desired program and click Install Follow the instructions that appear on the screen By default the installation c...

Страница 29: ...itter Tx to receiver Rx is required for serial command transmission But if you connect only one fiber optic cable there will be reduced control program functionality on the Rx unit For full functional...

Страница 30: ...tor is green when the transmitter detects light on the fiber optic cable connected to the Rx port NOTE The transmitter detects the receiver Tx to transmitter Rx light It reports the status to the rece...

Страница 31: ...es that let you manually set the DDC EDID resolution and refresh rate Video Adjustment area The Video Adjustment area provides slider controls that let you change the following video parameters Shift...

Страница 32: ...to Memory checkbox Click the Auto Memory checkbox to automatically apply saved position horizontal start total pixels and pixel phase settings when the sensed input resolution changes Auto Image butto...

Страница 33: ...ation figure 18 The message is displayed for approximately 1 second Figure 18 Alternate Audio Adjustment Area Indication Firmware upgrade Firmware can be upgraded for each unit via the PowerCage Confi...

Страница 34: ...wnload button 3 Figure 21 Personal Information Form 4 Follow the instructions on the rest of the download screens to download the firmware update from the Extron Web site start the Extron Installation...

Страница 35: ...or another file browser locate the Firmware Loader executable file in your computer s file system and double click on it to open it f Follow the instructions on the Installation Wizard screens to ins...

Страница 36: ...ose Firmware File Window 6 Navigate to and select the new firmware file Click Open The Choose Firmware File window closes NOTE When downloaded from the Extron Web site the firmware is placed in a subf...

Страница 37: ...The firmware upload to the switcher may take several minutes Once the status bars have progressed from 0 to 100 and Status is listed as Completed the firmware loader utility resets the unit 7 Figure 2...

Страница 38: ...ond fiber is required to transmit return data for bidirectional control communication Connectors 2 bidirectional LC connectors per FOX board Operating distance Singlemode 30 km 18 75 miles with single...

Страница 39: ...requency 40 Hz to 120 Hz Return loss 40 dB 5 MHz Video output PowerCage FOX 4G Rx VGA Number signal type With input from a FOXBOX 4G Tx VGA or a FOX 500 Tx 1 VGA UXGA RGBHV RGsB follows input or can b...

Страница 40: ...digitized in the transmitter sent through the fiber cable and converted back to analog audio in the receiver Gain Range Adjustable 18 dB to 10 dB Default Unbalanced output 0 dB Frequency response 20...

Страница 41: ...4G Rx DVI 5 8 watts Power input requirements for boards 12 VDC 1 0 A supplied by the PowerCage enclosure Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122...

Страница 42: ...Cage FOX 4G Tx DVI SM 70 700 12 PowerCage FOX 4G Rx DVI SM 70 700 22 PowerCage FOX 4G Tx DVI MM 70 700 11 PowerCage FOX 4G Rx DVI MM 70 700 21 Included parts These items are included in each order for...

Страница 43: ...o 3 to 50 0 9 m to 15 2 m molded 26 490 nn VGA A M M BK with audio 3 to 50 0 9 m to 15 2 m backshell 26 490 nn DVID SL 6 DVI D male to male 6 1 8 m cable 26 585 02 HDMI M M 6 HDMI male to male 6 1 8 m...

Страница 44: ...PUT RGB Po we rC ag e FO X 4G RX RG B Tx Rx L R AUDIO MONO AUDIO OUTPUT 1 2 SHARP GAIN Y VID C INPUT Po we rCa ge MT P R AV Tx Rx HD SDI INPUT HD SDI OUTPUTS MODE Po we rC ag e FO X 3G HD S DI 1 2 REM...

Страница 45: ...fective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 Europe 31 33 453 4040 Asia 65 6383 4400...