Quick Installation Guide
SAFETY WARNING
For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt,
or where required by the law, consult a competent person who is registered with an electrical self-certification
scheme. Further information is available online or from your Local Authority. INDOOR USE ONLY.
Please read carefully and use in accordance with these safety wiring instructions. Before commencing any
electrical work ensure supply is switched off at the mains. Either by switching off the consumer unit or by removing
the appropriate fuse. Wiring should be in accordance with the latest edition of IEE regulations (BS 7671). To prevent
fire hazard always use cable of the correct rating, size & type for the application.
Any bare earth wires must be covered with the appropriate green/yellow sleeving.
Warning do not exceed the load rating of this device as stated on rear of the product.
If in doubt always consult a competent electrician.
ENVIRONMENTAL PROTECTION
Electrical products should not be disposed of with your general household waste. Some chemicals
contained within electrical products can be harmful to health and the environment. Only dispose of the
items in seperate colletion schemes which can cater for recovery and recycling of materials contained
within. Your co-operation is vital to ensure the protection of the environment.
Wiring Instructions:
Wi-Fi Socket Range Extender N300 & Wi-Fi Socket Range Extender N300 + USB Charger
Positioning your Wi-Fi socket
Your Wi-Fi socket should be positioned half way between your router and the Wi-Fi dead-zone
Use the signal strength indicator on your mobile device to determine the mid-signal point
BEFORE COMMENCING WORK ALWAYS ISOLATE
THE POWER AT THE CONSUMER UNIT / FUSE BOX.
1. Unscrew the socket from the wall/mounting box.
2. Note the cable connections: There will generally be three different wiring
configurations, this illustration shows a single wire of each colour connected
to each terminal (there could be two or three wires of each colour connected
to each terminal) + an additional connection between the mounting box earth
terminal and the socket earth terminal.
3. Unscrew each terminal to release the wires.
Power off
Replacing an existing socket (removal)
1. Line up the new socket to mounting box and
take note of where each terminal is located.
2. Connect each wire to the matching terminal.
(refer to key in step 2)
An earth connection should always be made
between the mounting box earth terminal and the
socket earth terminal.
Make sure no copper wire is exposed & that only
the bare end enters the terminal.
3. Tighten terminal screws securely.
(do not over tighten)
1. Install mounting box (metal or patress) for
either flush or surface mounting, ensuring
appropriate size of product. (mounting box to
be purchased separately)
2. Select the most suitable entry point of
the mounting box (knock-out) and route the
supply cable through.
3. Cables should be prepared so a sufficient
conductor length reaches the terminals. Strip
the ends of the individual conductors leaving
an adequate length bare to enter terminals.
Wire up your socket
New installation
Product overview:
Wi-Fi Socket Range Extender
Rear of Socket
Wi-Fi Socket Range Extender
+ USB Charger
OFF
EARTH
LIVE
NEUTRAL
MOUNTING BOX
FROM SUPPLY
1. Carefully position the accessory into the
mounting box, ensuring that no wires are
trapped between the plate and the wall and
secure with screws (do not over tighten) then
set screw covers in place (optional).
Complete the installation
ON
2. Once installation has been completed
correctly, replace the fuse for the circuit,
switch the power back on at the consumer
unit and test.
2.1A
USB charging
socket
WI-FI SIGNAL ANTENNAS
SCREW
COVER
SCREW
HOLES
LED WI-FI
INDICATOR
WPS/RST BUTTON
NN
NEUTRAL
EARTH
TERMINALS
LIVE
L
USB Charger information:
2.1A USB port for charging mobile devices such as mobile phones, MP3 players and tablets.
2.1A 5V output from the USB output
• 2.1A is sufficient power output to charge the majority of USB products.
• The total output current achieved is dictated by specific device being charged and other external factors, such as the
quality of charging cable being used.
• Overload protection for connected devices.
Low energy stand-by mode
• When not in use the USB socket is in a low energy stand-by mode.
The USB circuits on this socket are designed to withstand insulation resistance tests at 500V. A reading of 0.4Ω +/-0.05
is typically caused by the USB socket
Note - The front surface of this product may become warm in use. This is normal and not cause for concern.
KNOCK-OUTS
OR
EARTH
= Green & Yellow sleeving
NEUTRAL
= Blue (Black pre Apr 04)
LIVE
= Brown (Red pre Apr 04)
EARTH
= Green & Yellow sleeving
NEUTRAL
= Blue (Black pre Apr 04)
LIVE
= Brown (Red pre Apr 04)
2a
2b
4
3
1
MOUNTING
BOX
EARTH
TERMINAL
Choose a location away from Bluetooth devices and other household electronics (cordless