User’s Manual
High Resolution Video and Audio
MTP Transmitters and Receivers
MTP 15HD A Series
68-956-02
Rev. E
12 09
Страница 1: ...User s Manual High Resolution Video and Audio MTP Transmitters and Receivers MTP 15HD A Series 68 956 02 Rev E 12 09...
Страница 2: ...machen da im Inneren des Geh uses dieses Produktesgef hrlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das...
Страница 3: ...ction against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in acco...
Страница 4: ...mounting 9 Connections and Settings 11 Transmitter 11 Power connection 11 Video and audio connections 11 Twisted pair connection and settings 12 Receiver 13 Power connection 13 Twisted pair connectio...
Страница 5: ...installation and operation of the following products MTP T 15HD A twisted pair TP transmitter MTP RL 15HD A receiver with loop through MTP RL 15HD A SEQ receiver with loop through and skew equalizati...
Страница 6: ...ther compatible MTP receiver or to a daisy chain of receivers N The transmitter provides pre peaking which boosts the signal before it is transmitted The buffered output on the receiver does not provi...
Страница 7: ...models but less preferable We also recommend the use of preterminated and tested cables Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications...
Страница 8: ...5 m 300 90 m 400 120 m 450 135 m 1366 x 768 250 75 m 300 90 m 400 120 m 450 135 m 1400 x 1050 250 75 m 300 90 m 350 105 m 400 120 m 1440 x 900 250 75 m 300 90 m 350 105 m 400 120 m 1600 x 1200 250 75...
Страница 9: ...mpatible with the maximum ambient temperature TMA specified by Extron TMA 122 F 50 C 2 Reduced air flow Installation of the equipment in a rack should be such that the amount of air flow required for...
Страница 10: ...RSU 126 1U 6 inch Deep Universal Rack Shelf Kit part number 60 190 10 RSB 126 1U 6 inch Deep Basic Rack Shelf part number 60 604 11 RSU 129 1U 9 5 inch Deep Universal Rack Shelf Kit part number 60 19...
Страница 11: ...the rear of the rack 1 Remove the feet from the bottom of the MTP if they are already installed 2 Mount the MTP using two 4 40 x 3 16 inch screws in opposite diagonal corners to secure the MTP to the...
Страница 12: ...to the front or rear rack supports and facing either towards the front or the rear of the rack M TP SER IES Figure 3 Attaching the back of the rack kit 1 Remove the feet from the bottom of the MTP if...
Страница 13: ...PEAK ON OFF MAV SERIES AV MATR IX SWITCHER I O AUD AUDIO SETU P PRESET VID IR d B d B ENTE R 2 7 6 5 2 4 1 IN PUTS OUTPUTS 8 3 1 8 6 5 4 3 7 M T P S E R I E S Rear Front Figure 4 Typical back of the r...
Страница 14: ...e mounting surface until just less than 1 4 inch 6 mm of the screw head protrudes 6 For furniture mounting align the mounting screws with the slots in the brackets and place the MTP against the surfac...
Страница 15: ...er supply wiring on page 16 to wire the connector Video and audio connections b Input video connector Connect a computer video source to this 15 pin HD connector for high resolution video input N Inpu...
Страница 16: ...io Twisted pair connection and settings e Pre Peak switch The Pre Peak switch alters the TP signal output to correct for long cable runs See the table on page 4 for suggested switch settings based on...
Страница 17: ...ed Output connector of an RL receiver to this RJ 45 female connector See TP cable termination on page 17 to wire the RJ 45 connectors g Buffered Output connector RL receivers only Connect one end of a...
Страница 18: ...DIP switches item j on the page 15 Video and audio connections and settings h Output video connector Connect a projector or other high resolution video device to this 15 pin HD connector i Mono Audio...
Страница 19: ...below Output signal format from the receiver Input signal format to the transmitter Receiver s DIP switch settings C Sync SOG Video RGBHV RGBS RGBHV RGsB RGBS RGsB RGsB Component S video Composite RGB...
Страница 20: ...A Captive Screw Connector Tie Wrap 3 16 5 mm Max Figure 10 Power connector wiring C Power supply voltage polarity is critical Incorrect voltage polarity can damage the power supply and the MTP Identi...
Страница 21: ...can power multiple Extron 12 VDC devices using only one AC power connector TP cable termination N RJ 45 termination with CAT 5 5e or 6 cable for non C7 units only or DTP26 or CAT 7 cable for C7 units...
Страница 22: ...around each wire pair and the shield around the DTP26 or CAT 7 cable are all tied to the RJ 45 connectors on both ends in accordance with the connector manufacturer specifications N The audio data tha...
Страница 23: ...RGB DELAY PEAKING LEVEL RED GREEN BLUE SELECT MTP SERIES 2 3 1 1 2 6 5 4 3 1 Figure 12 MTP front panels a Power LED This LED indicates power is applied to the MTP b Level control The Level control alt...
Страница 24: ...ush this button or when the selection times out after 10 seconds Press and hold this button for approximately 3 seconds to set the skew delay for Red Green and Blue to zero The Red Green and Blue LEDs...
Страница 25: ...ton 2 Use UTP cable test equipment or examine the displayed video image with a critical eye to determine which video signal Red Green or Blue is most shifted to the left N A crosshatch test pattern or...
Страница 26: ...methods to minimize or eliminate pair skew Switch to Extron Enhanced Skew Free A V UTP cable Add a skew compensation cable equal to the length of pair skew to the output of the receiver Install a SEQ...
Страница 27: ...B Y of component video 0 3 Vp p for C of S video Minimum maximum levels 0 3 V to 1 45 Vp p Impedance 75 ohms Horizontal frequency 15 kHz to 130 kHz Vertical frequency 30 Hz to 150 Hz Return loss 30 dB...
Страница 28: ...p Polarity Transmitter Positive or negative follows input polarity Receivers Positive or negative switch selectable Audio Number signal type 1 set of proprietary analog signals Connectors 1 female RJ...
Страница 29: ...humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Cooling Convection no vents Mounting Rack mount Yes with optional 1U rack shelf F...
Страница 30: ...s Part 12 VDC power supply 28 071 57LF MTP transmitter and receiver guide IEC power cord Rubber feet Accessories Accessories Part number PS 124 Multiple Output 12 V DC Power Supply 60 1022 01 RSU 129...
Страница 31: ...hanced Skew Free A V 1000 bulk Non Plenum 22 141 03 Extron Enhanced Skew Free A V 1000 bulk Plenum 22 142 03 N DTP26 or CAT 7 cables are recommended for C7 systems only DTP26 cable DTP26 1000 Non Plen...
Страница 32: ...ai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification...