MSG Matrix Switchers • Installation
2-7
Vertical Interval Switching
When the switching between inputs, the resulting image change should be
seamless and clean. Vertical interval switching makes this seamless image change
possible. MSG switchers are able to provide vertical interval switching by using an
external sync (genlock) signal to synchronize switching during the vertical sync
interval. Without external sync locking, switching between inputs can result in a
brief rolling (sync loss) or a brief change in the picture size. If no external sync
timing source is connected to the switcher, switching occurs immediately.
Connecting the external sync signal
The Genlock In connector of the MSG switcher receives the external sync timing
signal. The Genlock Out connector allows the signal to be passed on to another
video device, if required.
To enable vertical interval switching, connect an external sync signal (from an
Extron BBG6A Blackburst Generator or other source) to the Genlock In BNC
connector (
3
) for genlocking the video signal in broadcast or other sync-critical
applications. Connect any downstream equipment that requires genlocking to the
Genlock Out BNC connector to route the external sync signal through the switcher.
Содержание MSG0804
Страница 1: ...MSG0804 and MSG0808 Matrix Switchers 68 752 01 Rev A Printed in the USA 02 03 ...
Страница 10: ...MSG Matrix Switchers Introduction Introduction This page intentionally left blank 1 4 ...
Страница 18: ...MSG Matrix Switchers Installation Installation cont d 2 8 This page intentionally left blank ...
Страница 42: ...MSG Matrix Switchers Remote Control Remote Control cont d 5 12 This page intentionally left blank ...
Страница 43: ...MVP 104 Programmer s Guide A Appendix Specifications MSG Matrix Switchers ...
Страница 52: ...MSG Matrix Switchers Reference Information B 6 This page intentionally left blank ...