5-17
MPX Plus 866 A Media Presentation Matrix Switcher • Switcher Software
PRELIMINAR
Y
Soft limits ( ) are adjustable, letting you set the ceiling and floor for the group.
Grouped faders move together at relative levels to the top or bottom of their travel.
If one fader reaches the limit of its travel first, it retains that position while the other
faders continue to travel. When the grouped faders travel in the reverse direction,
the fader that was at its limit reverts to its position relative to the other faders. No
gain block’s level fader can be set beyond the group fader’s upper or lower limits,
either the hard limits or the soft limits. Any gain fader in the group can be set to a
level below the group fader.
An icon in the gain control indicates that a gain control is assigned to a group; in
figure 5-9, indicates group 2. in the output 3 control indicates that that gain
control is assigned to more than one group.
N
If a block is muted, that block remains muted when the group mute is released.
T
Extron recommends that if you include a control in multiple groups, that you do so
with care; overlapping group membership can quickly become unmanageable.
Configuring a group master
Configure a group as follows:
1
.
Click
Tools
>
Configure Groups
to open the Configure Groups dialog box.
N
Or, click
View
>
Group Controls
and then click the
Add a Group
menu selection.
2
.
In the Select Group drop-down box, click a group to select it (figure 5-11).
2
3
4
5
7
Figure 5-11 — Configure Groups dialog box
N
<empty> groups have no group members assigned. Numbered groups (such as
“Group #1“) have controls assigned that may be overwritten if you select them
and continue.
3
.
In the Select Control Type field, click the
+
to expand the Gain and/or Mute
tree and then select a control to assign it to the group.
4
.
In the Available Group Members field, click the desired checkboxes to select
or deselect those blocks as members of the group.
N
Potential group members in step
4
that are already assigned to a different group
are displayed in
blue
.
5
.
Click the
Apply
button to create or configure the group.
6
.
If desired
, repeat steps
2
through
5
to create or configure other groups.
7
.
Click the
Close
button to exit the Configure Groups dialog box.
Содержание MPX Plus 866 A
Страница 1: ...MPX Plus 866 A Media Presentation Matrix Switcher 68 1193 01 Rev B 05 09 ...
Страница 4: ......
Страница 20: ...Introduction cont d MPX Plus 866 A Media Presentation Matrix Switcher Introduction 1 10 PRELIMINARY ...
Страница 188: ...HTML Operation cont d MPX Plus 866 A Media Presentation Matrix Switcher HTML Operation 6 24 PRELIMINARY ...
Страница 189: ...PRELIMINARY MPX Plus 866 A A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer ...
Страница 196: ...Ethernet Connection cont d MPX Plus 866 A Media Presentation Matrix Switcher Ethernet Connection A 8 PRELIMINARY ...
Страница 197: ...PRELIMINARY MPX Plus 866 A B Appendix B DSP SIS Commnads Command Response Table for DSP SIS Commands ...
Страница 208: ...DSP SIS Commands cont d MPX Plus 866 A Media Presentation Matrix Switcher DSP SIS Commands B 12 PRELIMINARY ...
Страница 209: ...PRELIMINARY MPX Plus 866 A C Appendix C Reference Information Specifications Part Numbers ...
Страница 218: ...Reference Information cont d MPX Plus 866 A Media Presentation Matrix Switcher Reference Information C 10 PRELIMINARY ...
Страница 219: ...C 11 MPX Plus 866 A Media Presentation Matrix Switcher Reference Information PRELIMINARY Button label blanks ...
Страница 220: ...Reference Information cont d MPX Plus 866 A Media Presentation Matrix Switcher Reference Information C 12 PRELIMINARY ...