Extron Comm-Link Control System cable
Wire specifications for Extron Comm-Link cable (figure A-3) are
as follows:
A (red) = 18 American Wire Gauge (AWG)
B (violet or blue) = 22 AWG (grouped and shielded)
C (white) = 22 AWG
D (drain) = 24 AWG
E (black) = 18 AWG
Comm-Link cable was designed for use with MKP
control panels.
SuperFlex Plenum
Jacket
Fiber Wrap
Two 22 AWG
(White and Violet or Blue)
One 24 AWG
Tinned Copper Drain Wire
(foil-shielded group)
B, C
D
Two 1
8
AWG
(Red and Black)
A, E
Figure A-3 — Extron Comm-Link cable
Changing Button Labels
The MKP ships with default labels installed in the front panel
buttons (figure 3-2, “Input/output selection mode labels), but
includes a strip of alternate labels that you can insert in one or
more of the mode selection buttons to make using the other
modes clearer.
To change the labels in the MKP’s buttons,
1
.
Remove the button from the MKP by
grasping the button firmly and
pulling it away from the panel.
Various button models are
available. Your buttons
may
appear different.
2
.
Use a small screwdriver or Extron
Tweeker to gently lever the button
cap off of the white backing plate.
3
.
Insert a button label into the cap
and gently but firmly press the
cap onto the white backing plate.
4
.
Press the button into place in the
MKP.