IR 501

Unmute an output

Press the 

UNMUTE

 button to unmute all video and audio outputs.

All of the switcher’s Output LEDs flash on for a second.

Troubleshooting

If the switcher does not properly respond to IR remote control
functions, check the following:

• You may be too far from the switcher.  The maximum operating

range is 30 feet.

• You may be too far to the side of the switcher.  The remote

control must be pointed within 30 degrees of the switcher’s IR
sensor for best results.

• You may be taking too long to enter the sequence.  The unit

times out if no command is received in 5 seconds.

• The two AAA batteries may be dead.  Replace the batteries as

shown in figure 1.

• The switcher’s front panel security lockout may be on.  Toggle

the security lockout off.  See the appropriate switcher’s
manual.

• The room lighting may be interfering with the IR signals.  Keep

the switcher out of bright light.

Содержание IR 501

Страница 1: ...1 Unmute an output Press the UNMUTE button to unmute all video and audio outputs All of the switcher s Output LEDs flash on for a second Troubleshooting If the switcher does not properly respond to IR remote control functions check the following You may be too far from the switcher The maximum operating range is 30 feet You may be too far to the side of the switcher The remote control must be poin...

Страница 2: ...n buttons The I O buttons select inputs and outputs to tie The switcher s front panel Input LEDs indicate the selected input or output These buttons also select among presets to save or recall 2 10 button The 10 button is used with the other I O buttons to select numbers higher than 0 through 9 3 Enter button The Enter button saves changes when you create a new tie or configuration function button...

Страница 3: ...les show operations with specific input output and preset numbers Use your own numbers as desired The switcher s Power LED flashes whenever the switcher receives an IR command Other switcher indications are identified in the following examples where appropriate For detailed descriptions of how the switcher indicates ties and presets refer to the appropriate matrix switcher s manual Many operations...

Страница 4: ...ut as described in the switcher s manual 4 Allow the switcher s 5 second input and output button timeout to deselect the output Presets Save a preset 1 Create all desired ties 2 Press the SAVE button to specify a save preset operation 3 Press the PRESET button to specify preset mode The switcher s Preset LED blinks and for preset numbers that are within the switcher s total number of inputs and ou...

Отзывы: