Extron electronics IP Link IPL EXP 200 Скачать руководство пользователя страница 41

IPL EXP I/O Series • Software-based Configuration and Control

33

Downloading the Software and Getting Started

GC software updates and a large variety of device drivers can be downloaded from the 

Download

 page on the Extron website (

www.extron.com/download/index.aspx

). 

When you locate the desired software or driver package, follow the on-screen directions to 
download and install it.

NOTE:

 

New RS-232 and Ethernet drivers are required

. Use serial and Ethernet 

drivers developed specifically for the IP Link Pro platform. With the exception of IR 
device drivers, drivers used for the previous generation IP Link (non-Pro) control 
processors are not compatible.

Locating Software, Firmware, and Driver Files on the Extron Website

There are three main ways to find software, firmware, and device drivers within 

www.extron.com

:

• 

Via links from the web page for the specific product

• 

Via the 

Download Center

 page (Click on the 

Download

 tab at the top of any page 

within the Extron website.)

• 

Via links from search results

NOTE:

  For some software you have the option to click the 

Download

 button to begin 

downloading the software file. For other software there is a link for contacting an 
Extron support representative who can provide you access to the latest version.
To obtain Extron control product software, you must have an Extron Insider account 
and contact an Extron support representative. Extron provides training to our 
customers on how to use the software. For Global Configurator Professional, you 
must first attend Extron training, pass a proficiency test, and achieve Extron Control 
Professional Certification before being able to access all the features of that program.

Via links from the web page for the specific product

1. 

Navigate to the web page for the specific product model by performing one of the 
following:

• 

Enter the model name into the search field in the upper right of any Extron web 
page and click the 

magnifying glass

 icon.  

Or...

 

• 

Select the model name from the 

Product Shortcuts

 drop-down list in the 

upper left of the Extron home page or 

Products

 page.

2. 

Click the 

Downloads

 tab in the middle of the product page. A list of available software, 

firmware, and documents for that model appears on screen.

3. 

Click on the name of the desired software or firmware to start downloading the file, or 
click on the link for device drivers to navigate to a page from which you can select either 
a driver package or specific drivers for individual devices.

Via the Download Center page

1. 

Click on the 

Download

 tab at the top of any page within the Extron website to access 

the 

Download

 page.

2. 

Click on the link for the desired software product category (such as Global Configurator 
Professional, firmware, or control system device drivers) in the center of the screen. A 
page opens that allows you to make more specific selections from within that category.

Содержание IP Link IPL EXP 200

Страница 1: ...IPL EXP I O Series Control System Expansion Interfaces 68 3490 01 Rev A 08 21 User Guide IP Link Pro xi Products...

Страница 2: ...Safety Instructions...

Страница 3: ...ault PowerCage PURE3 Quantum ShareLink Show Me SoundField SpeedMount SpeedSwitch StudioStation SystemIntegrator TeamWork TouchLink V Lock VN Matrix VoiceLift WallVault WindoWall XPA XTP XTP Systems an...

Страница 4: ...interference must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Sa...

Страница 5: ...device responses mentioned in this guide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the...

Страница 6: ......

Страница 7: ...s a Key to Extron specific File Names 38 Secure Sockets Layer SSL Certificates 39 IEEE 802 1X Certificates 40 Certificate File Requirements 40 Private Key File Requirements 41 SNMP 41 Introduction 1 B...

Страница 8: ...Series Contents vi Firmware Updates 42 Determining the Firmware Version 42 Using Toolbelt Software 42 Using a Browser 42 Updating the Firmware 43 Locating and Downloading the Firmware 43 Installing F...

Страница 9: ...tware help files describe how to use each program to download drivers add AV devices to a configuration configure basic functions and set up schedules macros e mail alerts touchpanel button configurat...

Страница 10: ...els Extron NBP Network Button Panels and IPL EXP expansion interfaces Most IPCP Pro xi Series control processor models except the IPCP Pro S1 xi and the IPL EXP 200 also support Extron eBUS button pan...

Страница 11: ...ides 12 VDC and 24 VDC output ports that are used in conjunction with the digital I O ports All other models accept PoE or PoE input on the LAN PoE port Network and configuration features Global compa...

Страница 12: ...x G REMOTE LAN PoE IPL EXP S5 Tx Rx G COM Tx Rx G RESET 1 2 Tx Rx G Tx Rx G 3 4 Tx Rx G 5 Ethernet TLP Pro 1220MG 1 2 PWR PWR 3 PoE OUT PoE OUT G Tx Rx G Tx Rx COM 2 COM 3 RELAYS 2 1 4 3 C C AV LAN LA...

Страница 13: ...tion to the control processor To obtain Extron control product software you must have an Extron Insider account and contact an Extron support representative Extron provides training to our customers o...

Страница 14: ...ecklist Get Ready Familiarize yourself with the features of the IPL EXP Expansion Iinterface see Front Panel Features on page 10 and Ports Addressing and Connections on page 13 and of any IPCP Pro xi...

Страница 15: ...IEEE 802 1X security obtain a PEM encoded security certificate and private key see IEEE 802 1X Certificates on page 40 from your IT department Mount and Cable All Devices Mount the unit to a rack or...

Страница 16: ...under what circumstances Configure ports on the control processor Select device drivers and link them to each serial IR serial or Ethernet port Select settings serial protocol relay behavior digital I...

Страница 17: ...al guide to setting up the expansion interface for network use Open the Toolbelt software from within Global Configurator GC Professional or GC Plus mode or as the stand alone application Start Device...

Страница 18: ...7 8 12V24V G 12 VDC 24 VDC 19W MAX TOTAL LAN PoE LAN PoE IPL EXP S2 Tx Rx G COM Tx Rx G RESET 1 2 LAN PoE IPL EXP S5 Tx Rx G COM Tx Rx G RESET 1 2 Tx Rx G Tx Rx G 3 4 Tx Rx G 5 LAN PoE IPL EXP 200 V S...

Страница 19: ...it for installation procedures and see the UL rack mounting guidelines below for safe installation Then securely mount the control system expansion interface and other devices and attach cables using...

Страница 20: ...EXP To attach the EXP to the ZipClip 200 mounting clip 1 Insert the bottom of the EXP down into the clip starting with one end 2 Pivot the other end down and press until the clip snaps into place To r...

Страница 21: ...ate side facing the mounting surface of the furniture and with the tab accessible from the front of the furniture 2 Insert the EXP into the ZipClip 2 as described previously and press to snap it into...

Страница 22: ...on ou dans les cavit s murales The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadian Electrical Code part 1...

Страница 23: ...s the IPL EXP RIO8 enters the limit mode The Limit condition is indicated within Global Configurator and the ports are operational If you have configured the unit to do so the IPL EXP RIO8 can issue a...

Страница 24: ...19 watts All power output ports shut off Power will be restored after you correct the excessive power draw from the connected devices Sensor LED accessory or similar item Sensor LED accessory or simi...

Страница 25: ...M RS 232 Select protocol via software COM port default protocol 9600 baud 8 data bits 1 stop bit no parity no flow control NOTE The 3 pole COM ports support software flow control only Serial COM Ports...

Страница 26: ...s configure the settings and IP addresses via Toolbelt See the help file for Global Configurator or Toolbelt for basic information on configuration See the diagram on the next page and see the followi...

Страница 27: ...e unit is powered and operational Ethernet Link LED Activity LED 100 Mbps Connection Network is active Data is being sent received or TCP IP Network LAN Ethernet Default protocol public ports Default...

Страница 28: ...t options IR 30 kHz to 300 kHz with or without carrier signals Unidirectional RS 232 or Figure 9 Wiring the IR Serial Port Serial control Connect the IR S port to the serial control receive Rx and gro...

Страница 29: ...All relays are normally open Relay LEDs Light when the corresponding relays are activated tied to GND closed Figure 10 Cabling Relay Ports These relay contacts may be used to control any equipment as...

Страница 30: ...to Monitor or trigger events and functions toggle relays issue commands send e mail once configured Power LEDs or other devices that accept a TTL signal Switch Sensor 2 1 12V 24V G Heat Shrink Over Sh...

Страница 31: ...ensor connection Control Signal Ground 5 0 V 1k ohms SW 2 SW 1 Digital I O GND Voltage Protection CTL Occupancy Sensor Figure 12 Digital I O Digital Input Application Occupancy Sensor Without Pull up...

Страница 32: ...To activate LEDs incandescent lights or other devices that accept a TTL signal or to provide contact closure control for projector lifts motorized screens room or light switches via an Extron IPA T R...

Страница 33: ...ED External 5 VDC Power Source Resistor R Figure 14 Digital I O Digital Output Application LED and External 5 VDC Power Source Without Pull up To determine the value of the current limiting resistor i...

Страница 34: ...ther device via its contact closure input port Connect the digital I O port to the contact input port of another device such as an Extron DTP transmitter When activated the digital I O digital output...

Страница 35: ...ogy Reference Guide for the recommended distance from the expansion interface or control processor to the last eBUS device and maximum quantity of devices per control processor The IPL EXP can provide...

Страница 36: ...G S S V G S S V Powered eBUS device s eBUS Connections Connect up to four 4 eBUS devices to the eBUS distribution hub EBDB MINI Wire the connectors the same at both ends ATTENTION Do NOT connect the...

Страница 37: ...Universal Boot Code reset mode and replace firmware 1 On the IPL EXP expansion interface hold down the recessed Reset button while applying power to the unit Keep holding the button down until the Res...

Страница 38: ...reset the unit to all factory default settings 1 Hold down the Reset button until the Reset or Power LED blinks once at 3 seconds twice at 6 seconds and three times at 9 seconds 2 Release and press t...

Страница 39: ...d and controlled via a host computer connected to the same network as the control processor see LAN PoE and LAN PoE Ethernet connectors and LEDs starting on page 18 for details about LAN port and cabl...

Страница 40: ...interfaces or button panels if used to the project Import GUI layouts and configure the touchpanels or other interfaces Test the system make adjustments finalize configuration Save the project Build...

Страница 41: ...account and contact an Extron support representative Extron provides training to our customers on how to use the software For Global Configurator Professional you must first attend Extron training pas...

Страница 42: ...download a driver for a specific device Via links from search results 1 Type the specific name of the software package such as Global Configurator or GUI Designer into the Search field in the upper r...

Страница 43: ...r panel features and covers basic hardware installation See Front Panel Features on page 10 and Ports Addressing and Connections on page 13 in this guide for features and settings for the ports you ar...

Страница 44: ...ecks the power load If the total load power draw is now within safe limits the unit automatically re enables the ports Within Global Configurator the port status returns to normal it is no longer in t...

Страница 45: ...rt does not exceed 250 mA eBUS Connections and Configuration Verify that the eBUS ports are wired correctly and that ground earthing wires are connected to the ground pins on every device in the syste...

Страница 46: ...l processor A License Information window opens To view a copy of a listed package license in the License Information window click the link in the License column for the relevant package This opens a c...

Страница 47: ...OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file types PEM file types are ASCII encoded and are the required format for uploading to...

Страница 48: ...rol system NOTES You must run Toolbelt as an administrator Machine certificates require a private key file which can be encrypted Certificate File Requirements PEM Privacy enhanced Electronic Mail fil...

Страница 49: ...nagement information between network devices It helps in monitoring of operations and factors such as packet usage memory usage remote password resets and collection of error information An informatio...

Страница 50: ...ee the Hardware Features and Installation section starting on page 6 the Software Based Configuration and Control section starting on page 31 and the IPL EXP I O Series Setup Guide Using Toolbelt Soft...

Страница 51: ...cutable installer file exe from the website and run the installer program The program stores the firmware file on the PC in C Program Files x86 Extron Firmware or C Program Files Extron Firmware withi...

Страница 52: ...oor South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnorm...

Отзывы: