DDC Switches

When the DVI-D source device boots up, it uses the Display Data Channel (DDC), a two-
way communication protocol, to obtain Extended Display Identification Data (EDID) 
from the display device. This allows the source to output a resolution that matches the 
capabilities of the display.
A bank of three switches allows the user to determine how the source device will obtain 
the EDID. The EDID can be obtained directly from the display device, or from the internal 
memory within. The three switches are:

EDID Minder — 

This switch must be on for the EDID Minder function to be 

enabled. The factory default for this switch is the off position.

Default EDID —

 When the Default EDID switch is on (factory default; see 

figure at right), an EDID showing a typical dual link DVI display resolution of 
2560x1600 @ 60 Hz is passed to the source device. The EDID Minder switch 
must also be on for the Default EDID switch to function.

Remote DDC —

 When this switch is off, the DDC is routed to the local 

monitor. When the switch is on, the DDC is routed to the remote display device.

See page 13 

for more information about configuring these switches to provide the source 

device with the correct EDID.

Control Pass-through

The DVI DL 201 Tx/Rx cannot be controlled by RS-232 or IR controls. 
However, they are able to pass signals from a control device to a 
remote device that is controlled by those signals.

NOTE:

  The RS-232 and IR communications are via a passive 

pass-through only; the transmitter and receiver neither 
generate nor respond to these signals.

Use the three-pole, 3.5 mm captive screw connector on the 
transmitter to input RS-232 or IR signals from a control device. Use 
the corresponding connector on the receiver to pass signals to the 
output display.

NOTE:

  The ideal length of exposed wire in the stripping process is 3/16 inch (5 mm). 

If longer than 3/16 inch, the exposed wires may touch, causing a short circuit. 
If shorter than 3/16 inch, the wires can be easily pulled out even if tightly 
fastened. 

 

Do not tin the wires. Tinned wire does not hold its shape and comes loose 
over time.

3-Pole

Captive Screw

Connector

3/16" (5 mm)

MAX

Tx Rx

Tx Rx

ON

1   2   3   

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

 

DVI DL 201 Tx/Rx • Panels and Cabling

10

Содержание Dual Link DVI Transmitter and Receiver DVI DL 201 Rx

Страница 1: ...68 1531 01 Rev C 11 10 DVI DL 201 Tx Rx User Guide DVI HDMI Dual Link DVI Transmitter and Receiver...

Страница 2: ...hen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie da...

Страница 3: ...dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the periph...

Страница 4: ......

Страница 5: ...ation 13 Using the EDID Minder to Read and Store EDID from a Display 13 Using the EDID Minder with the Default EDID 14 Using Pass through Mode with DDC Routed to a Local Monitor 15 Using Pass through...

Страница 6: ...DVI DL 201 Tx Rx Contents vi...

Страница 7: ...ual unit is shipped with a single external desktop 12 VDC power supply A single power supply connected to the transmitter is able to power both devices Using three CAT 5 5e 6 7 twisted pair cables DVI...

Страница 8: ...feet 30 m which is significantly further than the 15 feet 5 m specified for standard dual link DVI cables Local monitor output The transmitter has a DVI D output for connection to a local monitor DDC...

Страница 9: ...01 Rx Rear Panel DVI DL 201 Tx Front Panel The illustration below shows the front panel features of the DVI DL 201 Tx DVI DL 201 Tx DVI DUAL LINK TRANSMITTER 1 Figure 2 DVI DL 201 Tx Front Panel Featu...

Страница 10: ...the local monitor The LED gives the status of this process f DDC route switches Three DIP switches allow the unit to be configured to use the EDID Minder or route the DDC directly to the display g Co...

Страница 11: ...O LAN DVI DL 201 Rx Figure 5 DVI DL 201 Rx Rear Panel Features l Power input An optional 12 VDC power supply not provided connects to this two pole 3 5 mm captive screw connector NOTE The receiver can...

Страница 12: ...I D output carries a signal with a resolution up to 2560x1600 60 Hz The pin assignments for the DVI I output connectors are the same as those for the input connectors and are shown in the table below...

Страница 13: ...cable Extron strongly recommends DTP26 cable especially when using high resolutions such as 1920x1200 1600x1200 or 2560x1600 DTP26 cable is available as non plenum part number 22 214 03 or plenum par...

Страница 14: ...3 2 Green Orange Data 0 HPD Data 3 3 White orange White green IDCK RS 232 Tx IR N C 4 Blue Blue Data 1 DDC Clock Data 4 5 White blue White blue Data 1 12 V Data 4 6 Orange Green IDCK RS 232 Rx N C 7 W...

Страница 15: ...03 or plenum part number 22 215 03 Single link dual link DVI Dual link DVI carries signals at resolutions up to 2560x1600 60 Hz Single link DVI carries signals at resolutions up to 1920x1200 60 Hz Vid...

Страница 16: ...on the DDC is routed to the remote display device See page 13 for more information about configuring these switches to provide the source device with the correct EDID Control Pass through The DVI DL 2...

Страница 17: ...he IR signal remotely There are no responses and no requirement for a reverse pathway To connect the control device to the transmitter or the receiver to the IR emitter make the following connections...

Страница 18: ...ucture or similar structure Twisted pair cable 2 pin 5 carries a 12 VDC power signal This remote powering feature allows a single power supply connected to the transmitter to power both the transmitte...

Страница 19: ...n should be 15 feet 4 5 m or shorter 3 Apply power to the transmitter and the display device If necessary connect the power supply to the transmitter 4 Set the EDID Minder switch on the transmitter to...

Страница 20: ...isplay device s NOTE All display devices must be capable of handling resolutions equal to or greater than that of the device used to set the EDID Using the EDID Minder with the Default EDID 1 Set the...

Страница 21: ...must be capable of handling a resolution equal to or greater than that of the local monitor Using Pass through Mode with DDC Routed to the Remote Display NOTE This is the factory default setting NOTE...

Страница 22: ...the EDID Minder to read and store information from a display see pages 13 to 14 2 Prepare twisted pair cables see Terminating shielded cable 3 Connect the transmitter to the receiver see Connections 4...

Страница 23: ...the receiver Insure all three twisted pair cables are firmly seated in the correct receptacles No output signal or poor quality signal Check the integrity of the UTP or STP cables between the transmi...

Страница 24: ...ot be able to send a video signal or the signal may have the wrong resolution or refresh rate z z Ensure that the DDC DIP switches are set correctly for the EDID source see Configuration z z The sourc...

Страница 25: ...1 for loop through NOTE Dual link DVI is backwards compatible with all single link DVI HDMI signals Interconnection between transmitter and receiver Connectors 3 RJ 45 per unit for 3 cables connectin...

Страница 26: ...A for both transmitter and receiver NOTE Each transmitter and receiver can be powered locally by an external power supply The receiver can be powered remotely by a power supply connected to the transm...

Страница 27: ...y CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI MTBF 30 000 hours Warranty 3 years parts and labor NOTES FCC testing is conducted with STP shielded twisted pair cable All nominal levels are at 10...

Страница 28: ...e 10 pack 101 105 01 RSF 123 3 5 inches deep 1U rack shelf kit 60 190 20 RSB 123 3 5 inches deep 1U basic rack shelf 60 604 21 RSU 126 6 inches deep 1U rack shelf kit 60 190 10 RSB 126 6 inches deep 1...

Страница 29: ...efore install the equipment in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in the rack so that the equipm...

Страница 30: ...nder desk Mounting Mount the unit under a desk or podium using the optional Extron MBU 125 under desk mounting kit part number 70 077 01 for the DVI DL 201 Rx or the MBU 123 kit part number 70 212 01...

Страница 31: ...Airport Free Zone F12 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnorm...

Страница 32: ...hich source will be used for the EDID information and configure the DDC switches appropriately see pages 13 to 16 If necessary use the EDID Minder to read and store information from a display see page...

Отзывы: