background image

 

DTP2 T/R 211 • Installation and Operation

11

TP Cable Termination and Recommendations

The 

TIA/EIA

 

T

 

568B

 wiring standard is detailed in figure 6. Use this standard to terminate 

TP cables with RJ‑45 connectors.

5

Pin

1

2
3

6
7
8

4

Side

12345678

Insert

Twisted

Pair Wires

Pins:

RJ-45

Connector

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

TIA/EIA T

568 B

Figure 6. 

TP Cable Termination

ATTENTION:

• 

Do 

not

 use Extron UTP23SF‑4 Enhanced Skew‑Free AV UTP cable or STP201 

cable to link the XTP products or with DTP2 transmitters or receivers. The 
DTP2 211 does not work properly with these cables.

• 

N’utilisez pas le câble audiovisuel Skew‑Free UTP version améliorée UTP23SF‑4 
Extron ou le câble STP201 pour relier les produits XTP à des émetteurs ou 
récepteurs DTP2. Le DTP2 211 ne fonctionne pas correctement avec ces câbles.

Supported cables —

The DTP2 211 transmitter and receiver are compatible with CAT 6a, and  CAT 7 shielded 
twisted pair (F/UTP, SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cable.

Cable recommendations —

Extron recommends using the following practices to achieve full transmission distances up 
to 330 feet (100 meters) and reduce transmission errors.

• 

Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the 
best performance:

• 

XTP

 

DTP

 

24/1000

 

Non‑Plenum 1000 feet (305 meters) spool

• 

XTP

 

DTP

 

24P/1000

  Plenum 1000 feet (305 meters) spool

• 

XTP

 

DTP

 

24 Plug

 

Package of 10

• 

If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid 
conductor, STP cable with a minimum bandwidth of 400 MHz.

• 

Terminate cables with shielded connectors to the TIA/EIA T 568 B standard.

• 

Use no more than two pass‑through points, which may include patch points, punch 
down connectors, couplers, and power injectors. If these pass‑through points are 
required, use CAT 6 or 6a shielded couplers and punch down connectors.

NOTES:

   

When using CAT 6a and CAT 7 cable in bundles or conduits, consider the following:

• 

Do not exceed 40% fill capacity in conduits.

• 

Do not comb the cable for the first 65 feet (20 meters), where cables are 
straightened, aligned, and secured in tight bundles.

• 

Loosely place cables and limit the use of tie wraps or hook‑and‑loop fasteners.

• 

Separate twisted pair cables from AC power cables.

Содержание DTP2 T/R 211

Страница 1: ...User Guide DTP2 T R 211 DTP Systems HDMI Twisted Pair Transmitters and Receivers 68 2938 01 Rev D 11 21...

Страница 2: ...Safety Instructions...

Страница 3: ...oleVault PowerCage PURE3 Quantum ShareLink Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR TeamWork TouchLink V Lock VN Matrix VoiceLift WallVault WindoWall XPA XTP XTP Syste...

Страница 4: ...se of the user ATTENTION The Twisted Pair Extension technology works with unshielded twisted pair UTP or shielded twisted pair STP cables but to ensure FCC Class A and CE compliance STP cables and STP...

Страница 5: ...ide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 18...

Страница 6: ......

Страница 7: ...ons 15 Front Panel Features 15 Connecting to the Front Panel USB Port 17 Resetting 18 Analog Audio Embedding Transmitter 19 HDMI Audio De embedding Receiver 19 Remote Control 20 Introduction to SIS 20...

Страница 8: ...DTP2 T R 211 Table of Contents viii...

Страница 9: ...6a or CAT 7 STP or unshielded twisted pair UTP cable up to 330 feet 100 meters The DTP2 211 devices extend the digital signal to Legacy DTP inputs 330 feet 100 meters with a maximum resolution of up t...

Страница 10: ...gram DTP HDMI 330 Rx OVER DTP RS 232 IR Tx Rx Tx Rx G L R POWER 12V 0 7A MAX AUDIO SIG LINK DTP IN OUTPUTS POWER 12V 0 3A MAX IPL PRO S3 G Tx Rx RTS CTS G Tx Rx RTS CTS G Tx Rx RTS CTS COM 1 COM 2 COM...

Страница 11: ...HDCP transmission DDC channels are actively buffered allowing continuous communication between source and display Remote power capability For simplified installation the transmitter can be remotely p...

Страница 12: ...0 meters for all compatible resolutions when used with CATx shielded twisted pair cable Shielded twisted pair cabling with solid center conductor sizes of 24 AWG or better is recommended for optimal p...

Страница 13: ...ed Pair Cable 6 Connect an unbalanced stereo audio source to the 3 5 mm mini stereo input on the DTP2 T 211 see figure 2 B for an analog audio input 7 Connect a balanced or unbalanced stereo or mono a...

Страница 14: ...wer to the transmitter or receiver 14 Power on the source devices After the transmitter the receiver and their connected devices are powered up the system is fully operational If any problems are enco...

Страница 15: ...lug Connector balanced C HDMI input Connect an HDMI cable between this port and the HDMI output port or DVI port with an appropriate adapter of the digital video source NOTE See Securing the HDMI Conn...

Страница 16: ...screw port for bidirectional RS 232 and IR communication see RS 232 and IR Connector Wiring on page 14 to wire the connector C DTP2 In RJ 45 port Connect one end of the TP cable from the transmitter...

Страница 17: ...ative contacts Pour l audio asym trique connectez les manchons au contact au sol Ne PAS connecter les manchons aux contacts n gatifs Do not tin the wire leads before installing into the connector Tinn...

Страница 18: ...Loosen the HDMI connection mounting screw from the panel enough to allow the LockIt lacing bracket to be placed over it 2 The screw does not have to be removed 3 Place the LockIt lacing bracket on th...

Страница 19: ...P cable Cable recommendations Extron recommends using the following practices to achieve full transmission distances up to 330 feet 100 meters and reduce transmission errors Use the following Extron X...

Страница 20: ...ground potential differences one DTP2 211 unit cannot remotely power the other unit Each unit requires a local power supply See figure 7 to wire the captive screw connector and secure the power cord t...

Страница 21: ...correcte pourrait endommager la source d alimentation et l unit Les stries sur le c t du cordon voir figure 7 sur la page pr c dente permettent de rep rer le p le n gatif du cordon d alimentation To v...

Страница 22: ...the RS 232 device into the G pin of the DTP2 211 2 Wire the unterminated end of the IR cable to the third fourth and fifth pins of the 5 pole captive screw plug as shown in figure 7 a Connect the tra...

Страница 23: ...signal on the DTP In connector receiver DTP Link Status Lights when a transmitter or receiver detect a sink signal from a connected DTP device DTP Output Signal Lights when the transmitter or receiver...

Страница 24: ...INK OUTPUT SEND POWER OFF STATUS SEND POWER OFF DTP HDMI 330 Rx OVER DTP RS 232 IR Tx Rx Tx Rx G DTP HDMI 330 Tx OFF OFF ON ON OFF CATx Cable up to 330 100 m No Remote Power Local Power Supply Local P...

Страница 25: ...NPUT LINK OUTPUT SEND POWER OFF STATUS Figure 11 Connecting a PC to the DTP2 T 211 Front Panel USB Port If this is the first time the DTP2 211 has been connected to the PC the Found New Hardware Wizar...

Страница 26: ...utomatically Recommended radio button see figure 13 1 5 Click Next 2 NOTE You do not need to insert an installation disc The PC locates the driver needed and installs it in the correct location on the...

Страница 27: ...dded onto the HDMI signal Configure the analog audio embedding via SIS commands with three options Auto default The original embedded digital audio passes If audio packets are not detected analog audi...

Страница 28: ...case characters can be used interchangeably Commands do not require any special characters to begin or end the command string Each response from the DTP2 211 transmitter and receiver ends with a carri...

Страница 29: ...ode and tagged responses for queries X Text string of up to 24 characters Default DTP2 T 211 or DTP2 R 211 Alphanumeric characters and hyphens only No distinction between upper and lower case No space...

Страница 30: ...og audio output 2 UP Analog audio passed from the TX is output on the analog audio output DTP2 Remote Power View input output remote power ERPWR Verbose mode 2 3 X RpwrX View remote power setting on D...

Страница 31: ...d lower case No spaces First character must be a letter and the last character cannot be a hyphen View Device Information Query part number N n Verbose mode 2 3 Verbose mode 2 3 60 1631 52 Pno 60 1631...

Страница 32: ...ron com NOTE Upgrading the firmware does not overwrite the current configuration Downloading Extron Firmware Loader 1 On the Extron website mouse over the Download tab see figure 15 1 Figure 15 Locati...

Страница 33: ...Wizard screens to install Firmware Loader on the computer The installation creates the necessary subfolders of C Program Files and the necessary groups It places the appropriate files into the correc...

Страница 34: ...may cause the device to stop functioning L extension du fichier firmware doit tre s19 Si un fichier est ouvert avec une mauvaise extension l appareil peut arr ter de fonctionner Updating Firmware on...

Страница 35: ...DTP2T211 dtp2t211_A_v1 00_081518 S19 3 3 3 1 1 1 2 2 2 Figure 21 Add Device Window 8 Click the Browse button 3 in the New Firmware File Optional section 9 In the Open window locate and double click t...

Страница 36: ...oader window and the Add Device window closes If firmware is uploading to multiple devices do the following a Click Add Next 3 The first device is added to the Device section of the Firmware Loader wi...

Страница 37: ...gress bar with Uploading above it In the Device section the Progress column displays an incrementing percentage and another progress bar The Status column displays Uploading Connected DTP2 T 211 60 16...

Страница 38: ...32 vitez les diff rences de potentiel de mise la terre entre les sites d installation d metteur et de r cepteur de commutation qui pourraient endommager l quipement ou rendre l image invisible ou irr...

Страница 39: ...ention to supply connections other than direct connections to the branch circuit such as the use of power strips Consignes UL pour le montage en rack Les consignes UL Underwriters Laboratories suivant...

Страница 40: ...l quipement ou rendre l image invisible ou irr guli re Si une diff rence de potentiel ne peut tre vit e enlevez la connexion de mise la terre entre les unit s et alimentez les deux unit s localement T...

Страница 41: ...p Rear Panel Cover Screws 8 Plcs Set Jumper Switches 1 3 1 3 1 3 Figure 28 Opening the Transmitter and Receiver 3 Locate lift jumper off pins 1 and 2 and place on pins 2 and 3 see figure 29 Transmitte...

Страница 42: ...fourni avec une source d alimentation il doit tre aliment par une source d alimentation certifi e UL de classe 2 ou LPS avec une tension nominale 12 Vcc 1 5 A minimum Always use a power supply provid...

Страница 43: ...ranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were n...

Отзывы: