22
Installing the Extricom WLAN System
Connectors
Description
(EXSW-400/800)
LAN1, LAN2
(EXSW- 1200/2400)
LAN.
Only LAN1 is used for connection to the wired LAN.
LAN2 on EXSW-1200/2400 is currently not in use.
LAN1,LAN2
(Multi Series 1000)
2 GbE RJ-45, 2 GbE SFP combo ports – used to connect the switch
to the wired LAN. Use only GbE or SPF.
Only LAN1 is used for connection to the wired LAN.
LAN2 is used for Switch Cascade interconnect only.
WLAN (AP) Ports
RJ-45 connectors – used to connect Extricom APs to the switch.
These ports provide 802.3AF PoE compatible power.
Maximum current: 270 mA, 48 volts.
-
Do not connect any device other than Extricom APs to
the WLAN ports.
Table 1: Extricom EXSW-400/800/1200/2400/1600 Switch Connectors
Table 2 below describes the front panel LEDs of Extricom EXSW-400/800/1200/2400 and Multi
Series 1000 Appliance Platform.
LED
Color
Description
Power
None
No power
Green
Blinking
- switch is loading
On
- switch is ready/operational
Red
On
- Error after loading
Green-
Orange
Blinking
- RF localization error
LAN, LAN1, LAN2 Ports
Act/Link
Green
On
- connection
Blinking
- activity over connection
Off
- no connection
100
(EXSW-400/800 only)
Orange
On
- 100 Mbps full duplex connection
Off
- 10Mbps full duplex or no connection
100 /1000
(EXSW-1200/2400 only)
Orange
On
- 100 Mbps full duplex connection
Off
- No connection
Only a 100 Mbps LAN connection is
supported.