Confidential and proprietary information of Extreme Networks. © 2011 Extreme Networks, Inc.
All rights reserved. DRAFT. October 20, 2011
Summit Family Switches Hardware Installation Guide
365
International Safety of ITE
CB Report & Certificate per IEC 60950-1 2nd Ed. + National Differences
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards
EN 55022:2006+A1:2007 Class A
EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8-2006 (Harmonics)
EN 61000-3-3 2008 (Flicker)
ETSI EN 300 386 v1.4.1, 2008-04 (EMC Telecommunications)
2004/108/EC EMC Directive
International EMC certifications
CISPR 22: 2006 Ed 5.2, Class A (International Emissions)
CISPR 24:A2:2003 Class A (International Immunity)
IEC 61000-4-2:2008/EN 61000-4-2:2009
Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A
IEC 61000-4-3:2008/EN 61000-4-3:2006+A1:2008
Radiated Immunity 10V/m, Criteria A
IEC 61000-4-4:2004 am1 ed.2./EN 61000-4-4:2004/A1:2010
Transient Burst, 1 kV, Criteria A
IEC 61000-4-5:2005 /EN 61000-4-5:2006
Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC 61000-4-6:2008/EN 61000-4-6:2009
Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A
EC/EN 61000-4-11:2004
Power Dips & Interruptions, >30%, 25 periods, Criteria C
Country-specific
VCCI Class A (Japan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark
KCC Mark, EMC Approval (Korea)
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications)
ETSI EN 300 019 (Environmental for Telecommunications)
IEEE 802.3 Media Access
Standards
IEEE 802.3ab 1000BASE-T
Environmental Data
Environmental standards
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5 G
Operating conditions
Temperature range:
Summit X460-24t, X460-48t, X460-24x, and X460-48x
0° C to 45° C (32° F to 113° F)
Summit X460-24p, X460-48p
0° C to 40° C (32° F to 104° F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Shock (half sine): 30 m/s
2
(3 G), 11 ms, 60 shocks
Random vibration: 3 to 500 Hz at 1.5 G rms