background image

brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage
susceptible de provoquer un fonctionnement indésirable.

Warning
IC Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 35 cm
between the radiator and people or animals.

Warning
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de
35 cm de distance entre la source de rayonnement et des personnes ou des animaux.

Taiwan Regulatory Statement

Details about regulatory and compliance information for Taiwan.

取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻率、加大功率
或變更原設計之特性及功能。

低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並
改善至無干擾時方得繼續使用。前述合法通信,指依電信管理法規定作業之無線電通信。低功率射
頻器材須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

Taiwan Maximum Permissible Exposure (MPE) warning

AP460C

電磁波曝露量

 MPE 

標準

值 1mW/cm²

,本

品使用時建議應距離人體

 20

公分。送測

 

品實

 

 0.6262

mW/cm².

AP460S6C and AP460S12C (AP460SC series)

電磁波曝露量

 MPE 

標準

值 1mW/cm²

,本

品使用時建議應距離人體

 21

公分。送測

 

品實

 

 0.9484

mW/cm².

Avoid affecting the operation of nearby radar systems. 

應避免影響附近雷達系統之操作。

High-gain directional antennas can only be used in stationary point-to-point systems. 

高增益指向性天

線只得應用於固定式點對點系統。

Taiwan Regulatory Statement

Regulatory and Compliance Information

40

ExtremeWireless™ AP460C, AP460S6C, and AP460S12C Access Points

Содержание AP460C

Страница 1: ...ExtremeWireless AP460C AP460S6C and AP460S12C Access Points Installation Guide 9036823 03 Rev AB October 2020...

Страница 2: ...works and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in...

Страница 3: ...BKT ASM accessory bag contents 16 AH ACC STRP MRN accessory bag contents 16 Outdoor PoE 16 Micro USB order information 16 Access Point Mounting Options and Accessory Usage 17 Install the Access Point...

Страница 4: ...ty in Languages of the European Community 34 European Union EU Radiation Warning Statement 36 FCC Radiation Exposure Statement 38 Brazil Ag ncia Nacional De Telecomunica es Anatel Statement 39 Mexico...

Страница 5: ...e identified in the text When a feature function or operation pertains to a specific hardware product the product name is used When features functions and operations are the same across an entire prod...

Страница 6: ...fined in the text Italics are also used when referring to publication titles New information In a PDF this is searchable text Table 3 Command syntax Convention Description bold text Bold text indicate...

Страница 7: ...idance from GTAC Call GTAC For immediate support 800 998 2408 toll free in U S and Canada or 1 408 579 2826 For the support phone number in your country visit www extremenetworks com support contact B...

Страница 8: ...rs or confusing or conflicting information Improvements that would help you find relevant information in the document Broken links or usability issues If you would like to provide feedback you can do...

Страница 9: ...ccess points are based on advanced radio technology and IP67 rated for harsh and extreme outdoor environments with an extended temperature range from 40 C to 60 C The tri radio design delivers 802 11a...

Страница 10: ...de from the Actions drop down list 4 In the dialog box select the appropriate country from the drop down list and then select Save 5 Upload your changes to the device AP460C AP460S6C and AP460S12C Fea...

Страница 11: ...iate half duplex and full duplex connections with the connecting device The ports are autosensing and adjust to straight through and crossover standard Cat2 Cat5 Cat5e or Cat6 Ethernet cables automati...

Страница 12: ...escription Callout Description 1 NC 2 R D input to access point 3 T D output to terminal 4 Signal GND 5 Signal GND USB port These access points have a standard USB port that you can use to connect USB...

Страница 13: ...2 5VDC 57 0VDC Maximum 54 0VDC 0 43A 23 3W Max PoE with USB 2 5W IEEE 802 3at only 42 5VDC 57 0VDC USB 0 5A 54 0VDC 0 39A 20 8W Max PoE without USB 2 5W IEEE 802 3at only 42 5VDC 57 0VDC ESD protectio...

Страница 14: ...Q and is operating normally Slow blinking The device has a CAPWAP connection to ExtremeCloud IQ but is operating on 802 3af power instead of 802 3at power Amber Steady The device is initializing reboo...

Страница 15: ...ion procedures covered in this document is applicable to all these access points Procedure 1 Verify the box contents 2 Visually inspect the access point the bracket and any other optional accessories...

Страница 16: ...tents The AH ACC STRP MRN accessory is an outdoor stainless steel pole cable clamp for 3 in to 7 in diameter poles The accessory bag contains the following item One AH ACC STRP MRN stainless steel cab...

Страница 17: ...al power cord with European Union plug AH ACC PW CBL AU 6 ft universal power cord with Australia plug AH ACC PW CBL JP 6 ft universal power cord with Japan plug AH ACC PW CBL KR 6 ft universal power c...

Страница 18: ...ments If you are resting the access point under a horizontal pole use this installation method only during indoor warehouse or distribution center installations Caution Do not install the access point...

Страница 19: ...ert holes in the back of the access point 2 Top slots on the rear of the access point facing the sky 3 Bottom slots on the rear of the access point facing the ground Install the Access Point Install t...

Страница 20: ...s point LAN glands must face down to eliminate water from entering the chassis Install the Access Point on a Flat Surface Install the access point on a vertical or horizontal flat surface using the AH...

Страница 21: ...at surface Note The printed arrows on the accessory must be pointing up Figure 7 ASM accessory wall mounting hole markings 2 Attach the ASM accessory to the wall by using four M5 shoulder mounting scr...

Страница 22: ...t removed 6 Insert the M5 bolt heads on the access point into the large end of the accessory keyholes and slide the access point down until the bolts rest in the narrow end of the keyholes 7 Tighten t...

Страница 23: ...door environment you must provide protective grounding to prevent the access point from damages and failures Procedure 1 Strip the insulation off one end of the ground wire and attach the stripped wir...

Страница 24: ...al edge area 2 Ground terminal 3 10 AWG ground wire 4 M4 screw 5 Star washer 3 Tighten the screw to a torque of 12 in lbs 4 Connect the other end of the ground wire to an appropriate earthing location...

Страница 25: ...ure 1 Remove the sealing nut claw and the 2 part seal from the main body of the waterproof housing Assemble the pieces around the Ethernet cable as shown in Figure 10 Figure 10 Weatherproof Ethernet c...

Страница 26: ...to their counterparts on the main body 6 Insert the seal and the claw into the main body 7 Screw the sealing nut onto the threaded main body 8 Tighten it to a torque of 12 in lbs 9 Connect the other e...

Страница 27: ...le and the gland area 3 Use a thin strong and non conductive tool like a flat bladed orange stick to reach into the gland and press down the plastic locking latch of the RJ45 connector Warning Ensure...

Страница 28: ...irectional antennas AP460S6C AP460S6C and AP460S12C radio mapping information Sensor radio 2 4G 5G antenna 4 5G radio 4 4 antennas 3 5 6 and 7 IoT radio antenna 3 IoT or BLE antenna 2 4G radio antenna...

Страница 29: ...nt antenna gain Software mode WiFi0 WiFi1 WiFi2 IoT radio Azimuth beamwidth Elevation beamwidth Dual band 2 4 GHz 7 88 dBi 7 83 dBi 7 9 dBi 60 60 5 GHz 8 06 dBi 6 46 dBi Dual 5G 2 4 GHz 7 83 dBi 7 9 d...

Страница 30: ...ir Housing IP67 rated outdoor use Device specifications Chassis dimensions when mounted diagonally 11 375 in 11 375 in 2 900 in 289 000 mm x 289 000 mm x 74 000 mm Weight 4 lbs 1 8 kilograms Four dual...

Страница 31: ...l Frequency Division Multiplexing OFDM 54 48 36 24 18 12 9 6 with auto fallback N A N A 802 11b 2 4 2 5 GHz Direct Sequence Spread Spectrum DSSS 11 5 5 2 1 with auto fallback N A N A 802 11g 2 4 2 5 G...

Страница 32: ...s 1200 Mbps NSS 1 2 1 1 2 2 4 4 MIMO radio VHT20 VHT40 VHT80 VHT160 T BF 802 11ax for 5 GHz sensor 2 4 2 48 GHz 5 150 5 350 GHz and 5 470 5 850 GHz 802 11ax modulation 1024 QAM Dual band OFDMA HE_MCS0...

Страница 33: ...s countries in which the device can be used Safety Guidelines Learn about the safety guidelines that are intended to protect your personal safety and prevent damage to the equipment Important Only qua...

Страница 34: ...EU For den fulde ordlyd af EU overensstemmelseserkl ringen bedes du kontakte Extreme Regulatory Compliance p compliancerequest extremenetworks com Dutch Nederland Hierbij verklaart Extreme Networks d...

Страница 35: ...un ESB nr 2014 53 EU Fyrir fullan texta ESB yfirl singu um samr mi vinsamlegast haf u samband vi Extreme Reglufylgni compliancerequest extremenetworks com Italian Italiano Con la presente Extreme Netw...

Страница 36: ...pleto de la Declaraci n de conformidad de la UE p ngase en contacto con Extreme Regulatory Compliance en compliancerequest extremenetworks com Swedish H rmed intygar Extreme Networks att radioutrustni...

Страница 37: ...s d exposition aux rayonnements ces appareils devraient tre install s une distance minimale de 7 87 in 20 cm des personnes ou des animaux Restrictions 5150 5350 MHz pour usage int rieur seulement Germ...

Страница 38: ...mits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed...

Страница 39: ...ice use in Mexico La operaci n de este equipo est sujeta a las siguientes dos condiciones 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo o dispositivo de...

Страница 40: ...ion aux rayonnements IC tablies pour un environnement non contr l Cet quipement doit tre install et utilis avec un minimum de 35 cm de distance entre la source de rayonnement et des personnes ou des a...

Страница 41: ...ket 17 C compliance for japan indoor use 33 conventions notice icons 5 text 5 country code update 10 D documentation feedback 8 location 7 E EU radiation warning statement 36 F FCC radiation exposure...

Страница 42: ...1 802 11ax 31 802 11ax for 5 GHz sensor 31 802 11b 31 802 11g 31 802 11n 31 RJ45 cable removal 27 uninstall the access point 27 S safety guidelines 33 specifications device specifications 30 environme...

Отзывы: