6
present. Press the Mode Selection button to select an operating mode. The
charger will carry out a control measurement for about 90 seconds.
The display will show:
If 7.3V – 7.5V is detected, the 12V battery is defective. The charger will return
to standby.
Revitalizing
If the charger detects from 7.5V – 10.5V after 90 seconds, the charger will
begin a pulse charge to revitalize the 12V battery. The voltage display will
flash. Once the battery is charged to 10.5V, the charger will switch to the other
charge steps.
Revitalizing is the same for all 12V modes.
Mode Selection
Note: If battery has a voltage range of 3.7V – 7.3V, modes 2 ( ),3 ( ), and 4 ( )
cannot be selected.
The charging process takes place automatically.
Depending on the selected mode, the characteristic charge curve is monitored
for voltage, time, and temperature. The diagnostics program, revitalizing
program and retention charge are included.
Mode 1 – 6V Batteries (7.3V/0.8A)
For charging 6V batteries with a capacity of less than 14Ah.
Press the Mode Selection button to select Mode 1. “
6V
” will display on the
LCD. While charging, the charge display flashes and shows the progress of
the charge procedure. When the battery is fully charges, the condition display
shows 4 bars. The flashing stops and the charger automatically switches to
charge retention or “float” mode.
Mode 2 – 12V Batteries (14.4V/0.8A)
For charging 12V batteries with a capacity of less than 14Ah.
Press the Mode Selection button to select Mode 2.
The ( ) is displayed on the LCD. During charging, the charge display
---
88.8
V