background image

A

C

B

ENGLISH

Air inlet

REFERENCES

INFlammablE objECtS

NoN-INFlammablE objECtS

A

200 mm

100 mm

B

1500 mm

750 mm

C

200 mm

100 mm

floor protection

InstallIng Inserts

When installing inserts, access must be prevented to the internal parts of the appliance and it must not be possible to access live parts during 
extraction operations.
Any wiring, for example the power cable or room probe, must be positioned so as not to be damaged during movement of the insert and 
must not come into contact with hot parts.

VentIlatIon and aeratIon of the InstallatIon premIses

Ventilation is deemed sufficient when the room is equipped with air inlets according to the table:

appliance categories

Reference standard

Percentage of the 

net opening section with respect to 

the appliance fumes outlet section

minimum net opening value of 

the ventilation duct

Pellet stoves

UNI EN 14785

-

80 cm²

Boilers

UNI EN 303-5

50%

100 cm²

In any case ventilation is deemed sufficient when the pressure difference between the external and internal environment is equal to or less 

than 4 Pa.

InstallatIon

general

The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity 

documentation compliant with national standards.

the installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, 

supplied with:

1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);

2) photocopy or photograph of the chimney plaque;

3) system booklet (where applicable).

The installer must ask to be issued with a receipt stating that the documentation has been provided, and must keep it with a copy of the technical 

documentation relating to the installation.

For installation in a condominium, prior approval from the condominium's administrator must be requested.

Where required, check the exhaust gas emissions after installation. Should a sampling point be installed, it must be airtight.

CompatIBIlItY 

Installation in premises with fire hazards is forbidden. Installation in residential premises (except for sealed operation appliances) is also forbidden:

 

Š

in which there are liquid fuel-operated appliances with continuous or intermittent operation, which draw the combustion air in the 

room in which they are installed, or

 

Š

in which there are type B gas appliances intended for room heating, with or without production of domestic hot water and in adjacent 

and adjoining premises, or

 

Š

in which, in any case, the depression measured during installation between the internal and external environment is greater than 4 Pa 

InstallatIons In Bathrooms, Bedrooms and studIo flats

Installation in bathrooms, bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken 
from the outside.

posItIonIng and safetY dIstanCes 

The support surfaces and/or points must have a suitable capacity to bear the overall weight 
of the appliance, accessories and coverings. If the floor is made of a combustible material, 
we recommending using a non-combustible material to protect the front part from any 
burnt material which might fall during routine cleaning operations.
The generator must be level to function properly.

The adjacent, side and rear walls and the supporting surface must be made of non-
combustible material. Installation adjacent to combustible or heat sensitive materials is 
allowed as long as there is a suitable safety distance in between, which for pellet stoves is:

6

Содержание VIVIANA EVO

Страница 1: ...MADE IN ITALY design production VIVIANA EVO VIVIANA PLUS EVO pellet stoves USER MANUAL ENGLISH INGLESE 004276730 Rev 000 ...

Страница 2: ...ENGLISH 2 ...

Страница 3: ...COMFORT 16 Enable chrono 16 Chrono 16 Programming example 17 Cleaning And Maintenance 18 Maintenance 18 Cleaning and Maintenance by the user 18 ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS 22 PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON 22 Displays 25 ALARMS 26 GUARANTEE TERMS 27 ATTENTION SURFACES CAN BECOME VERY HOT ALWAYS USE PROTECTIVE GLOVES During combustion thermal en...

Страница 4: ...OF AGE OR OLDER AND INDIVIDUALS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT DANGERS The generator must not be used by persons including children with reduced physical sensory and mental capacities or who are unski...

Страница 5: ...ste Do not use any flammable liquids for ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can have micro dots crackles and chromatic imperfections These features highlight their valuable nature Due to their different dilation coefficient they produce crackling which demonstratetheir effective ...

Страница 6: ...hat the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s administrator must be requested Where required check the exhaust gas emissions after installation Should a sampling point be installed it must be airtight COMPATIBILITY Installation in premises with ...

Страница 7: ... base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is inserted in an existing flue it must be certified for solid fuel If the smoke duct is outside the building it must always be insulated The smoke ducts must have at least one ...

Страница 8: ... months of seasoning the calorific value of pellets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive at a sufficiently adequate degree of heat yield THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY A...

Страница 9: ...ed by means of the 4 supplied screws Additional thermostat functioning for ducting motor control For models with ducting motor there is also the possibility of thermostatting the motor itself The connection of an external thermostat will allow to control the ducting motor independently from stove functioning At this point just set the desired temperature on the thermostat The thermostat will contr...

Страница 10: ...stby activated Ign plug Off ign plug active On ign plug deactivated Flashing ignition phase Not used It indicates functioning of the fumes motor Off fumes motor not working On fumes motor working Flashing breakdown it indicates the communication between remote control and stove Every time a key is pressed on the remote control the indicator must switch on if the indicator is always on it indicates...

Страница 11: ...OILING HOT STOVE DURING THE FILLING PHASE In the event of continuous no ignition contact an authorised technician It is forbidden to use the appliance without the divider and or GLASS PROTECTION see figure atthe site jeopardisesthe safety of the product and leads to the immediate voiding of the warranty period In the case of wear or deterioration request after sales assistance for replacement of t...

Страница 12: ...y is required If the remote control is off because it has no batteries the stove can be controlled from the control panel on top of it While replacing the battery pay attention to the polarity by observing the symbol on the inside compartment of the remote control COMMISSIONING settings Once the power cable at the back of the stove has been connected move the switch also located on the back to I T...

Страница 13: ...ble to select the preferred language to display the various messages Controls procedure Press key 5 for a few seconds until set clock appears Press key 3 twice until SET LANGUAGE appears Confirm using key 5 Select the language using key 3 Press key 1 several times to confirm and exit the menu Language ITALIAN ENGLISH GERMAN FRENCH SPANISH PORTUGUESE J FAILURE TO IGNITE ALARM The first ignition may...

Страница 14: ... the Stand by function reducing pellet consumption to a minimum By default the STBY function is always set on OFF light on For its activation and logic follow the indications on the next page Chapter Stand by Burn pot cleaning During the work stage the stove has an internal counter which cleans the burn pot after a set amount of time This stage will be shown on the display it will bring the stove ...

Страница 15: ... SET CLOCK will appear on display Press the key 3 for several times to open the EASY SETUP page Press the key 5 to confirm Use the keys 2 and 3 to increase 3 or decrease 2 the value Press the key 1 for several times to confirm and exit the menu easy setup The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet This ratio can change while maintaining the qua...

Страница 16: ... chrono Press key 5 to confirm and use keys 2 3 to enable ON or disable OFF the chrono Use keys 4 5 to select the desired time slot Press keys 2 3 to enable ON or disable OFF the COMFORT mode for the selected time slot Press key 1 several times to confirm and exit the menu J When the COMFORT mode is active the LED for fan 1 will flash on the control panel When the COMFORT function is activated usi...

Страница 17: ...he scrolling text with the day of the week followed by OFF Use key 3 to enable disable ON OFF all days Monday prg1 on off Press key 5 to confirm and continue programming The scrolling text START PRG1 OFF will appear Start Prg1 Off Press key 5 to confirm and continue programming The text START PRG2 OFF will appear Start prg2 on off 1st time slot switch on Using keys 2 3 enter the time 08 00 which c...

Страница 18: ...sed and the frequency of use It can happen that these operations should be performed more frequently Cleaning and Maintenance by the user Routine cleaning operations as specified in this use and maintenance manual must be performed with the utmost care according to the instructions procedures and frequency intervals described in this use and maintenance manual CLEANING THE SURFACES AND COVERING Ne...

Страница 19: ... 3 1 4 Use the special poker supplied to clear the holes in the burn pot 5 Place back the burn pot and push it towards the hearth wall 6 If there is an ash collector tray vacuum the ash deposits PLEASE NOTE Use a suitable vacuum cleaner with a special container to separate the collected ash Open the door Clean the glass with a damp cloth Never spray the detergent or any other liquid used for clean...

Страница 20: ... heat exchangers chamber must be cleaned every month as the soot deposited on the rear of the hearth wall obstructs the regular flow of fumes thereby affecting the performance and regular operation of the stove Open the door to access the combustion chamber Take out the burn pot Remove or rotate depending on the model the upper lockbolt A the screws B or the wall lock C of the hearth wall D take o...

Страница 21: ...A B C E E E F F D F D D ENGLISH 21 ...

Страница 22: ...st be carried out by a qualified technician CONNECTION TO THE FLUE Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections any residue must be removed before it obstructs the flue PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON At the end of every season before turning off the stove we recommend completely emptying the pellet tank and u...

Страница 23: ...and burn pot door replace them and apply silicone where required C Combustion chamber total cleaning of the entire chamber and ignition plug tube cleaning D Tank complete emptying and cleaning E Room air fan disassembly and removal of dust and any pellet debris F Air intake pipe inspection and of flow sensor cleaning The images are for illustration purposes 23 ...

Страница 24: ...rn pot door replace them and apply silicone where required C Combustion chamber total cleaning of the entire chamber and ignition plug tube cleaning D Tank complete emptying and cleaning E Room air fan disassembly and removal of dust and any pellet debris F Air intake pipe inspection and of flow sensor cleaning The images are for illustration purposes 24 ...

Страница 25: ... STAND BY function see the specific chapter Cooling stand by A new ignition is attempted when the stove has just been switched off When the stove switches off it is necessary to wait for the complete shutdown of the fumes motor before cleaning the burn pot The stove can only be re ignited when these operations have been performed Cool stdby black out The stove is cooling due to black out On comple...

Страница 26: ...ation operations must be carried out by an authorised technician DEPR ALARM The mechanical depression sensor has tripped Contact after sales centre No Ignition The pellet feed box is empty Pellet feed calibration inadequate Incorrect installation Check for the presence of pellets in the feed box Adjust the pellet flow see Pellet feed adjustment Check the procedures described in the Ignition chapte...

Страница 27: ...lity to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarantee will be void Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee Similarly are excluded defects related to incorrect operation of the flue...

Страница 28: ...et pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product with the door open or if the glass is broken The product must be electrically connected to a system equipped with an operational earthing system Turn off the product in the event of a failure or mal...

Страница 29: ...ENGLISH 29 ...

Страница 30: ...ENGLISH 30 ...

Страница 31: ...ENGLISH 31 ...

Страница 32: ...o extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the characteristics and the data reported in this pamphlet at any moment and without notice in order to improve its products This manual therefore cannot be regarded as a contract towards other partie...