background image

20

ENGLISH

enabling/Disabling the Chrono

CONTrOls prOCeDUre

 

Š

press 6.

 

Š

press 3 until 

cHrono

 appears and confirm by pressing key 6.

 

Š

Confirm 

EnABLing 

by pressing 6.

 

Š

Use keys 4 -5 to enable (

on

) or disable (

oFF

 

Š

press 6 to confirm or 1 to return to the previous menus to the initial state.

J

if the weekly Chrono is aCtive on the Control panel, a sMall iCon is DisplayeD

cHrono

>

EnABLing

>

Prg1

On/off

Enable/disable PRG 1

>

Prg2

On/off

Enable/disable PRG 2

>

Prg3

On/off

Enable/disable PRG 3

>

Prg4

On/off

Enable/disable PRG 4

Prg1

>

STArT Prg1

OFF-00:00

Ignition time PRG1

>

SToP Prg1

OFF-00:00

Switch-off time PRG1

>

monDAY...SUnDAY

On/off

Enable/disable the days of PRG1

>

SET Prg1

LOW-TA - 07- 37 °C - HOT

Set thermostat PRG1

>

PowEr Prg1

1-5

Set power PRG1

Prg2

>

STArT Prg2

OFF-00:00

Ignition time PRG2

>

SToP Prg2

OFF-00:00

Switch-off time PRG2

>

monDAY...SUnDAY

On/off

Enable/disable the days of PRG2

>

SET Prg2

LOW-TA - 07- 37 °C - HOT

Set thermostat PRG2

>

PowEr Prg2

1-5

Set power PRG2

Prg3

>

STArT Prg3

OFF-00:00

Ignition time PRG3

>

SToP Prg3

OFF-00:00

Switch-off time PRG3

>

monDAY...SUnDAY

On/off

Enable/disable the days of PRG3

>

SET Prg3

LOW-TA - 07- 37 °C - HOT

Set thermostat PRG3

>

PowEr Prg3

1-5

Set power PRG3

Prg4

>

STArT Prg4

OFF-00:00

Ignition time PRG4

SToP Prg4

OFF-00:00

Switch-off time PRG4

monDAY...SUnDAY

On/off

Enable/disable the days of PRG4

SET Prg4

LOW-TA - 07- 37 °C - HOT

Set thermostat PRG4

PowEr Prg4

1-5

Set power PRG4

Chrono

This function allows you to program the stove to switch on and off automatically.

The factory setting for 

cHrono

 is off.

The chrono allows you to program 4 time slots within a day to be used for every day of the week. 

in each time slot, it is possible to set the ignition and switch-off times, the days of use of the programmed time slot, the desired 
temperature and the set power. the current date and time setting is essential for the correct operation of the timer.

recommendations
Before using the chrono function, you must set the current day and time, so check that you have followed the points listed in the sub-
chapter “DATE-TimE”. To make sure that the chrono function works properly, as well as programming it, it is also necessary to activate it. 

The 4 time slots can be overlapped by setting the ignition and switch-off times. in this way, a combination of times is obtained in which 
it is possible to set different temperatures and powers without affecting the operating status of the stove. 

n.B.: if there are overlapped time slots, the product will remain on until the furthest switch-off time.

Содержание Marilena Plus AD

Страница 1: ...MADE IN ITALY design production MARILENA PLUS AD 004277269 Rev 000 UK pellet stoves USER MANUAL...

Страница 2: ...2 ENGLISH...

Страница 3: ...Enabling disabling the chrono 20 Settings 22 Display 22 stand by 22 OPERATION with additional thermostat optional 22 Additional thermostat 23 Installation of additional thermostat 23 delta t 23 First...

Страница 4: ...well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is in...

Страница 5: ...ply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible after installation Do not close or reducethe dimensions ofthe airingvents in the...

Страница 6: ...uid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICALLY THANKS TO THE TIMER OR REMOTELY USING THE DEDICATED APPLICATIONS IT IS STRICTLY...

Страница 7: ...thoutdomestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances...

Страница 8: ...tion If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is...

Страница 9: ...K Combustion air inlet C Combustion chamber access L On Off D Lateral fumes exhaust Fuse E Room air output 230v power supply F Display M Serial input G Upper fumes exhaust Additional thermostat input...

Страница 10: ...allow for the duct motor to be controlled regardless of stove operation At this point simply set the desired temperature on the thermostat the thermostat will command the operation of the second moto...

Страница 11: ...llowing CLOSE HOPPER DOOR This message indicates that you have 60 seconds to close the hatch door and pellet lid After the 60 seconds during the ignition phase the stove will go to DEPR ALARM mode whi...

Страница 12: ...OOR QUALITY PELLETS OR ANY OTHER MATERIAL WILL COMPROMISE STOVE FUNCTIONS VOIDING THE WARRANTY AND RELEASING THE MANUFACTURER OF LIABILITY Pellet hopper pressurised closure During stove operation the...

Страница 13: ...On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay F...

Страница 14: ...gnal receiver Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight...

Страница 15: ...bled On the function is enabled Indicates the stove modulation On the stove is operating at the set power Flashing the power at which the stove is operating is not the set power the stove is modulatin...

Страница 16: ...t is recommended to Ventilate the room well If present remove any majolica parts from the top of the product Activate the product at the maximum power and temperature Avoid remaining in the room for a...

Страница 17: ...eturn to the previous menus to the initial state Language This menu allows you to set the preferred language The available languages are Italian English German French Spanish Portuguese Controls proce...

Страница 18: ...e the set temperature has been reached the stove automatically reduces the power ensuring optimal comfort and reducing the consumption of pellets this process is called modulation LOW TA hot If the Se...

Страница 19: ...CREASE RANGE SECOND INCREASE RANGE IF THE FIRST IS NOT ENOUGH THIRD INCREASE RANGE IF THE FIRST TWO ARE NOT ENOUGH Controls procedure Press 6 Press key 3 until easy setup appears and confirm by pressi...

Страница 20: ...g3 1 5 Set power PRG3 prg4 Start prg4 OFF 00 00 Ignition time PRG4 Stop prg4 OFF 00 00 Switch off time PRG4 Monday Sunday On off Enable disable the days of PRG4 Set prg4 LOW TA 07 37 C HOT Set thermos...

Страница 21: ...23 00 08 00 16 30 t 22 18 2 1 21 ENGLISH Time slot 1 start 02 00 stop 23 00 power 3 set thermostat 22 C Time slot 2 start 08 00 stop 16 30 power 1 set thermostat 18 C stove operation Time slot Set po...

Страница 22: ...exceeds the value of the Set Thermostat DELTA T OFF then the stove will switch off after a preset delay displaying STAND BY When the room temperature is lower than the Set Thermostat DELTA T and afte...

Страница 23: ...pears and confirm by pressing 6 Use keys 4 5 to enable ON disable OFF Press 1 several times to confirm and exit the menu J FOR CORRECT OPERATION SET THE SET ROOM THERMOSTAT TO LOW TA Additional thermo...

Страница 24: ...e to comply with these instructions may damage the surfaces of the generator and result in the invalidation of the warranty Cleaning the ceramic glass Never use abrasive or chemically aggressive deter...

Страница 25: ...ied Put the burn pot back in place and push it towards the back wall Put the pellet slide assembly back in place above the burn pot Make sure that the burn pot and pellet slide have been positioned co...

Страница 26: ...26 ENGLISH Cleaning the combustion chamber deflector Remove the deflector and eliminate the ash that has deposited at the top of the deflector...

Страница 27: ...o clean and remove the burn pot it is necessary to remove the pellet slide assembly B by lifting it To put it back in place perform the same operation in reverse order After repositioning it make sure...

Страница 28: ...rranty SEALS pellet hopper lid DOOR ASH DRAWER AND BURN POT The seals ensure that the stove is airtight and they guarantee the proper operation of the same They must be regularly checked if they are f...

Страница 29: ...ed points B Seals pallet hopper inspections ash drawer and door replace and apply silicone where required C Combustion chamber exchanger total cleaning including cleaning the glow plug duct D Hopper e...

Страница 30: ...ed points B Seals pallet hopper inspections ash drawer and door replace and apply silicone where required C Combustion chamber exchanger total cleaning including cleaning the glow plug duct D Hopper e...

Страница 31: ...by pressing key 1 for 3 seconds Fumes motor fault Fumes motor failure Contact the service centre Fumes probe Fumes probe fault Contact the service centre Hot fumes High exhaust temperature Check pell...

Страница 32: ...bility to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guar...

Страница 33: ...aults in the electrical insulation This can cause electric shocks Installations not complying with the regulations in force as well as incorrect use and failure to comply with the maintenance schedule...

Страница 34: ...34 ENGLISH...

Страница 35: ...35 ENGLISH...

Страница 36: ...extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary th...

Отзывы: