27
ENGLISH
InstallatIOn mUst Be perFOrmed By qUalIFIed staFF and/Or the manUFactUrer's serVIce technIcIans
addItIOnal FUnctIOns
sUpplementary thermOstat InstallatIOn (OptIOnal)
The stove can control the room temperature through a supplementary thermostat (optional).
After ignition (by pressing key 1 or in chrono mode), the stove will work to reach the set value on the thermostat, displaying WorK (closed
contact) on the screen. The standard room sensor is by-passed automatically.
When the thermostat temperature has been reached (open contact), the stove switches to minimum power level and displays moDuLATIon
on The SCreen.
ConTroLS proCeDure
A mechanical or digital thermostat with a “normally open” input is required.
remove the plug from the socket.
using the image to the side as a guide, connect the two thermostat wires (clean contact - no
230 V!).
Connect the power to the stove again.
press key 3, until the
SET THERMOSTAT
is on
LOW-TA
.
delta t
This function allows you to set the hysteresis to switch the stove on and off
DeLTa T
,
used as a room temperature adjustment interval if not
managed by an external thermostat. The exact temperature for ignition is
SeT ThermoSTaT - DeLTa T
.
The exact temperature for switch-off
is
SeT Ther DeLTa T
.
The possible values for
DeLTa T
go from:
0.5 - 5°c
To set:
oK > SeTTINgS > DeLTa-T
FIrst lOad
This function allows you to activate the gearmotor for loading pellets continuously.
Before starting the function, make sure the stove is cold and “oFF”.
To set:
oK > SeTTINgS > fIrST LoaD
To stop continuous loading, just press and hold key 6 for 2 seconds.
QuICK ACCeSS:
Before starting the function, make sure the stove is cold and “oFF”.
press keys 6 + 4 at the same time for two seconds until the message “FIrST LoAD” is displayed.
To stop continuous loading, just press and hold key 6 for 2 seconds.
reset
Allows the user to reset all editable values to the default values.
To set:
oK > SeTTINgS > reSeT.
depressUre nOtIce
It allows you to activate the buzzer for acoustic warnings if the door or the hopper are open.
Please note: Activation can reduce battery life by 30%.
The battery life depends on the usage
To set:
oK > SeTTINgS > DepreSSUre NoTIce
PlEAsE NOTE: ThE TErmINAl CAN bE FOUND IN ThE bAg INsIDE ThE sTOVE.