background image

1

2

3

19

CLEANING

Chapter 6

CLEANING

Maintenance operations guarantee correct functioning of the product through time.
Failure to comply with these operations can jeopardise the safety of the product.

USING THE GRATE SHAKER COMBS

During normal stove functioning the cinders must be 
shaken to prevent stratifi cation of the ash. To do this 
use the grate shaker combs, whose lever is accessible 
by opening the lower box: hook the supplied irons 
to the lever to prevent burns and move forward-
backwards and vice versa. Repeat the operation 2-3 
times a day.

ASH DRAWER

The ash drawer must be emptied on necessity.
Open the lower door for access.

CLEANING THE BURNER

The burner must be cleaned on necessity and every 
time the product is ignited again.

Remove the cast iron burner cover

 

™

Use the grate shaker combs to remove and 

 

™

combustion residues.

Using the cleaning rod, scrape the fi nal part of 

 

™

the pellet tank to remove any deposited residues.

remove the ash and the unburned pellets from 

 

™

the burner using a suction device.

CLEANING 

THE BURNER

GRATE SHAKER 

COMBS

ASH 

DRAWER

 

fi gure 6.1

 

fi gure 6.2

 

fi gure 6.3

Содержание Cleopatra

Страница 1: ...Stufe a Pellet User manual Cleopatra Read the instructions carefully before installation use and maintenance The instruction book is an integral part of the product...

Страница 2: ...2...

Страница 3: ...e space in that is dedicated to your authorised specialist He will help you with pleasure if you should have problems using your new pellet stove AUTHORISED SPECIALIST COMPANY ________________________...

Страница 4: ...CONNECTION TO THE FLUE AND EXHAUST OF THE COMBUSTION PRODUCTS 15 CHIMNEY CAP 15 CONNECTION TO EXTERNAL AIR INLETS 16 INSULATION FINISHINGS COVERINGS AND SAFETY RECOMMENDATIONS 16 NATIONAL REGIONAL PRO...

Страница 5: ...e stove must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning The stove must be serviced at least once a year programming it...

Страница 6: ...to the water kW Min useful heat output kW 4 0 useful output power to the air kW 4 0 useful output power to the water kW Min hourly fuel consumption kg h 1 0 Max hourly fuel consumption kg h 2 0 Feed...

Страница 7: ...7 TECHNICAL FEATURES Chapter 2 figure 2 1...

Страница 8: ...s a calorific value of 4 4 kW kg with 15 humidity therefore after about 18 months seasoning that of the pellet is 5 3 kW kg Pellet density is about 650 kg m3 and water content is equal to 8 of its wei...

Страница 9: ...owto 1 feed the pellets and check the correct positioning of lever A Open the handle of the tank lid 2 On opening the tank lid there is a compartment 3 with a capacity equal to about 5 kg where the pe...

Страница 10: ...the stove it is impossible to open the tank lid Once the pellet has descended take the knob A to its original position position 2 6 To fill the tank to maximum capacity just repeat the points from nu...

Страница 11: ...geological formation and transformed in fossil BIOFUEL Fuel produced directly or indirectly by biomass CHIMNEY Vertical pipe with the aim to collect and expel at a convenient height from the ground t...

Страница 12: ...rminals positioning of appliances similarly to No installation Legal distances Limitations disposed by local administrative regulations or particular authority prescriptions Conventional limitations d...

Страница 13: ...condensate and avoid it being transported towards the appliance The mounting of horizontal routes must be avoided For appliances where ceiling or wall non coaxial discharges respect to the appliance s...

Страница 14: ...mmable objects Non inflammable objects A 200 100 B 1500 750 C 200 100 the appliance must be installed on a floor that has suitable load capacity If the existing construction does not satisfy this requ...

Страница 15: ...outlet section not lower than double the chimney internal section be built in order to avoid rain snow foreign bodies penetrating the chimney and in order that in case of winds in any direction and in...

Страница 16: ...xternal environment by means of reverse draught caused by the presence of another used appliance or intake deviceinsuchroom Thepermanentopeningsintheadjacentroommustcomplywiththeabove described requis...

Страница 17: ...The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste AIR REGISTER The Cleopatra stove has a register for the regulation of primary...

Страница 18: ...the feed box is always half full 3 SWITCH OFF Cleopatra is supplied with a system that interrupts pellet supply to the burner using a lever it is possible to block the natural sliding of the pellet to...

Страница 19: ...ever to prevent burns and move forward backwards and vice versa Repeat the operation 2 3 times a day ASH DRAWER The ash drawer must be emptied on necessity Open the lower door for access CLEANING THE...

Страница 20: ...to prevent explosion Do not use cloths abrasive or chemically aggressive products GASKETS The gaskets guarantee the tightness of the stove and its consequent good functioning These must be checked re...

Страница 21: ...r inspection lid positioned incorrectly Check sealing of the upper lid gaskets of the intermediate base of the tank the lateral inspection lid and the upper inspection lid If they are worn contact qua...

Страница 22: ...transversal section of the flue is excessive Butterfly valve in the closed flue Flue draught too low Burner dirty and blocked Gaskets used Upper inspection lid positioned incorrectly Al piping must be...

Страница 23: ...After sales Service or the dealer Thewarrantdocument filled inandaccompaniedbythereceipt mustbekeptandshowntostaffofthe 3 Extraflame S p A Technical After sales Service in the case of intervention Th...

Страница 24: ...ea After Sales Centre For products sold abroad the same situations will always be free of charge ex our establishment with the exception of particular conditions agreed during negotiations with the fo...

Страница 25: ...ed by the company with full respect of the Legislative Decree 196 2003 for the entire duration of the contractual relationship and subsequently in order to fulfil all legal requirements as well as to...

Страница 26: ...26 Notes...

Страница 27: ...27 Notes...

Страница 28: ...003 0810008 EXTRAFLAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 http www lanordica extraflame com E mail info extraflame com This documen...

Отзывы: