A.
EMPTYING THE COLLECTING BIN (WITH A CLOSING FLAP)
The collecting bin of a device equipped with a cutoff valve can be emptied while the unit is
running. When the collecting bin becomes full, the signal light on the display unit illuminates,
and the cutoff valve closes.
After emptying the bin
y
ou must confirm the procedure by
pressing 'F4' to open the seal.
It is possible to empty the collecting bin during use even if it is not full. You must first close the
seal of the collecting bin by pressing 'F1' on the display device and holding for four seconds;
then you can detach the collecting bin.
After emptying the bin
y
ou must confirm the
procedure by pressing 'F4' to open the seal.
AFTER THE CUTOFF VALVE HAS CLOSED
1.
Disconnect the overfill sensor plug.
2.
Open the fastening latches of the
collecting bin (2kpl).
3.
Empty the collecting bin.
4.
Remove the dust gathered at the bottom
of the taper and check the condition of
the seal.
5.
Make a hole with a diameter of approx.
15 mm to the plastic bag.
6.
Place the plastic bag in the collecting bin,
so that the hole comes inside the
collecting bin.
7.
Mount the collecting bin.
8.
Connect the overfill sensor plug.
9.
Acknowledge the procedure with the F4
button.
Ø 15 mm