SYSTEM CONTROL SETTINGS
OVERFILL OF THE COLLECTING TANK
The extraction system turns off when the overfill sensor of the collecting tank has been
triggered for a specified period. The time limit can be changed on the display panel. A time limit
of one hour has been pre-defined by the factory.
WARNING! After switching off the system, it performs cleaning the filter
after operation. Do not open the service door during the cleaning
process!
MESSAGES ON THE DISPLAY OF THE CONTROL PANEL
During operation, the operating time, the actual pressure difference across the filter and the
pressure difference and the clearing limits are shown on the display. In addition, an error
message may also appear.
The following alarm messages are displayed on the panel display:
Phase monitoring: ’PHASE AND SEQUENCE LOSS’
Safety switch switched on: ’SAFETY SWITCH’
Heat relay of the motor: ’THERMAL RELAY’
The overfill sensor indicates that the collecting bin is full: ’EMPTY THE COLLECTING BIN
> PRESS F4 4S’
Recommended maintenance interval exceeded: ’INSPECTION PUSH F4 10S WHEN
SERVICE HAVE DONE’
Acknowledge the alarm messages displayed on the control panel with the "F4" key.