6
SDL720-en-GB_V1.0 12/16
Max
‐
Min
Reading
Record
For
a
given
measurement
session,
this
meter
can
record
the
highest
(MAX)
and
the
lowest
(MIN)
readings
for
later
recall.
1.
Press
the
MAX
‐
MIN
button
momentarily
to
access
this
mode
of
operation
(REC
icon
appears).
2.
The
meter
is
now
recording
the
MAX
and
MIN
readings.
3.
Press
the
MAX
‐
MIN
button
again
to
view
the
current
MAX
readings
(MAX
icon
appears).
The
readings
on
the
display
are
now
the
highest
readings
encountered
since
the
REC
icon
was
switched
on
(when
the
MAX
‐
MIN
button
was
first
pressed).
4.
Press
the
MAX
‐
MIN
button
again
to
view
the
current
MIN
readings
(MIN
icon
appears).
The
readings
on
the
display
are
now
the
lowest
readings
encountered
since
the
REC
icon
was
switched
on
(when
the
MAX
‐
MIN
button
was
first
pressed).
5.
To
exit
the
MAX
‐
MIN
mode,
press
and
hold
the
MAX
‐
MIN
button
for
at
least
1.5
seconds.
The
meter
will
beep,
the
REC
‐
MAX
‐
MIN
icons
will
switch
off,
the
MAX
‐
MIN
memory
will
clear,
and
the
meter
will
return
to
the
normal
operating
mode.
Fittings
Connection
Connect
tubing
to
the
P1
(+),
P2
(
‐
),
or
both
input
port(s).
If
both
inputs
are
used
(differential
mode),
the
meter
displays
a
positive
pressure
reading
if
the
P1
(+)
pressure
is
greater
than
P2
(
‐
)
and
a
negative
reading
if
P2
(
‐
)
is
greater
than
P1
(+).
Datalogging
Types
of
Data
Recording
Manual
Datalogging:
Manually
log
up
to
99
readings
onto
an
SD
card
via
push
‐
button
press.
Automatic
Datalogging:
Automatically
log
data
onto
an
SD
memory
card
where
the
number
of
data
points
is
virtually
limited
only
by
the
card
size.
Readings
are
logged
at
a
rate
specified
by
the
user.
SD
Card
Information
Insert
an
SD
card
(from
1G
size
up
to
16G)
into
the
SD
card
slot
at
the
bottom
of
the
meter.
The
card
must
be
inserted
with
the
front
of
the
card
(label
side)
facing
toward
the
rear
of
the
meter.
If
the
SD
card
is
being
used
for
the
first
time
it
is
recommended
that
the
card
be
formatted
and
the
logger’s
clock
set
to
allow
for
accurate
date/time
stamping
during
datalogging
sessions.
Refer
to
the
Setup
Mode
section
for
SD
card
formatting
and
time/date
setting
instructions.
European
and
USA
numerical
formats
differ.
The
data
on
the
SD
card
can
be
formatted
for
either
format.
The
meter
defaults
to
USA
mode
where
a
decimal
point
is
used
to
separate
units
from
tenths,
i.e.
20.00
.
The
European
format
uses
a
comma,
i.e.
20,00
.
To
change
this
setting,
refer
to
the
Setup
Mode
section.
www.calcert.com
1.888.610.7664
0
5
10
15
20
25
30