background image

5

   

                                     

SDL720-en-GB_V1.0   12/16

 

 

Enabling/Disabling

 

the

 

Auto

 

Power

 

OFF

 

Feature

  

1.

 

Access

 

the

 

PoFF

 

parameter.

 

2.

 

Use

 

the

 

arrow

 

buttons

 

to

 

select

 

ON

 

or

 

OFF.

 

With

 

the

 

Auto

 

Power

 

OFF

 

feature

 

enabled,

 

the

 

meter

 

will

 

automatically

 

switch

 

OFF

 

after

 

10

 

minutes

 

of

 

inactivity.

 

3.

 

Press

 

ENTER

 

to

 

confirm

 

setting.

 

4.

 

Press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

at

 

least

 

1.5

 

seconds

 

to

 

exit

 

to

 

the

 

normal

 

operation

 

mode

 

(or

 

simply

 

wait

 

7

 

seconds

 

for

 

the

 

meter

 

to

 

automatically

 

switch

 

to

 

the

 

normal

 

operating

 

mode).

 

 

Set

 

the

 

Beeper

 

Sound

 

ON

 

or

 

OFF

  

1.

 

Access

 

the

 

bEEP

 

parameter.

 

2.

 

Use

 

the

 

arrow

 

buttons

 

to

 

select

 

ON

 

or

 

OFF.

   

3.

 

Press

 

ENTER

 

to

 

confirm

 

setting.

 

4.

 

Press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

at

 

least

 

1.5

 

seconds

 

to

 

exit

 

to

 

the

 

normal

 

operation

 

mode

 

(or

 

simply

 

wait

 

7

 

seconds

 

for

 

the

 

meter

 

to

 

automatically

 

switch

 

to

 

the

 

normal

 

operating

 

mode).

 

Numerical

 

Format

 

(comma

 

or

 

decimal)

  

European

 

and

 

USA

 

numerical

 

formats

 

differ.

 

The

 

meter

 

defaults

 

to

 

USA

 

mode

 

where

 

a

 

decimal

 

point

 

is

 

used

 

to

 

separate

 

units

 

from

 

tenths,

 

i.e.

 

20.00

;

 

The

 

European

 

format

 

uses

 

a

 

comma,

 

i.e.

 

20,00

 

to

 

separate

 

units

 

from

 

tenths.

 

To

 

change

 

this

 

setting:

 

1.

 

Access

 

the

 

dEC

 

parameter.

 

2.

 

Use

 

the

 

arrow

 

buttons

 

to

 

select

 

USA

 

or

 

EUro.

   

3.

 

Press

 

ENTER

 

to

 

confirm

 

setting.

 

4.

 

Press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

at

 

least

 

1.5

 

seconds

 

to

 

exit

 

to

 

the

 

normal

 

operation

 

mode

 

(or

 

simply

 

wait

 

7

 

seconds

 

for

 

the

 

meter

 

to

 

automatically

 

switch

 

to

 

the

 

normal

 

operating

 

mode).

 

SD

 

Card

 

FORMATTING

  

1.

 

Access

 

the

 

Sd

 

F

 

parameter.

 

2.

 

Use

 

the

 

arrow

 

buttons

 

to

 

select

 

YES

 

to

 

format

 

the

 

card

 

(select

 

NO

 

to

 

abort).

 

Note

 

that

 

all

 

data

 

on

 

the

 

card

 

will

 

be

 

lost

 

if

 

formatting

 

is

 

attempted.

 

3.

 

Press

 

ENTER

 

to

 

confirm

 

selection.

 

4.

 

Press

 

ENTER

 

again

 

to

 

re

confirm.

 

5.

 

The

 

meter

 

will

 

automatically

 

return

 

to

 

the

 

normal

 

operating

 

mode

 

when

 

formatting

 

is

 

complete.

 

If

 

not,

 

press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

at

 

least

 

1.5

 

seconds

 

to

 

exit

 

to

 

the

 

normal

 

operation

 

mode.

 

System

 

Reset

 

If

 

the

 

meter’s

 

keys

 

become

 

inoperable

 

or

 

if

 

the

 

display

 

freezes

 

the

 

Reset

 

button

 

can

 

be

 

used

 

to

 

reset

 

the

 

instrument.

 

 

Use

 

a

 

paper

 

clip

 

or

 

similar

 

item

 

to

 

momentarily

 

press

 

the

 

reset

 

button

 

located

 

on

 

the

 

lower

 

right

 

side

 

of

 

the

 

instrument

 

under

 

the

 

snap

off

 

compartment

 

cover.

 

 

After

 

pressing

 

the

 

Reset

 

button,

 

switch

 

the

 

instrument

 

ON

 

by

 

pressing

 

and

 

holding

 

the

 

POWER

 

key

 

for

 

at

 

least

 

1.5

 

seconds.

 

If

 

using

 

the

 

power

 

adaptor

 

unplug

 

the

 

adaptor

 

and

 

then

 

plug

 

it

 

back

 

in

 

again

 

to

 

power

 

the

 

meter.

 

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Содержание SDL720

Страница 1: ...User Manual Heavy Duty Differential Pressure Manometer Model SDL720 Additional User Manual Translations available at www extech com www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Страница 2: ...ustomer Support Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 P1 Input positive 2 P2 Input negative 3 LCD Display 4 HOLD and Backlight key 5 MAX MIN key 6 SET and Clock key 7 RS232 output jack 8 Reset button 9 Power Adaptor jack 10 SD card slot 11 ENTER and LOG key 12 Do...

Страница 3: ...he currently selected unit of measure is shown below the measurement value on the meter s LCD To change the unit of measure press and hold the UNIT button until the desired unit of measure appears and then release the UNIT button The meter begins scrolling through the available units of measure see table below after the UNIT button has been depressed for at least 1 5 seconds UNIT DISPLAY INDICATOR...

Страница 4: ... rate Hours Minutes Seconds PoFF Automatic power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 SdF Format the SD memory card Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys to change a value 3 Use the ENTER button to step through the selections 4 Press and ...

Страница 5: ...ter 2 Use the arrow buttons to select USA or EUro 3 Press ENTER to confirm setting 4 Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode or simply wait 7 seconds for the meter to automatically switch to the normal operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow buttons to select YES to format the card select NO to abort Note tha...

Страница 6: ...the meter displays a positive pressure reading if the P1 pressure is greater than P2 and a negative reading if P2 is greater than P1 Datalogging Types of Data Recording Manual Datalogging Manually log up to 99 readings onto an SD card via push button press Automatic Datalogging Automatically log data onto an SD memory card where the number of data points is virtually limited only by the card size ...

Страница 7: ...ero 2 Press and hold the LOG button for at least 1 5 seconds The meter will flash the DATALOGGER icon at the selected sampling rate indicating that readings are now being automatically recorded to the SD card 3 If a card is not inserted or if the card is defective the meter will display EMPTY and exit the DATALOGGER mode In this case switch the meter OFF and try again with a valid SD card 4 Pause ...

Страница 8: ...to a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example AC Power Adaptor This meter is normally powered by six 6 1 5V AA batte...

Страница 9: ...se Couplings This meter is supplied with a pair of hose couplings They fit 4 0mm 0 157 tubing See diagram on how to connect these couplings to the hose and the meter www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Страница 10: ...ery compartment cover with the two 2 Phillips screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take ...

Страница 11: ...en logging at a 1 second rate MANUAL LOGGING Set the sampling rate to 0 seconds Select 1 to 99 locations Data error number 0 1 number of total saved data Memory Card SD memory card 1G to 16GB size Data Hold Freeze the displayed reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Operating Temperature 0 to 50 C 32 to 122 F Operating Humidity ...

Страница 12: ...s H2O 0 5 20 40 m H2O 0 01 1 974 ATP 0 001 Conversions Useful conversion Factors From To Multiplier in of H2O in of Hg 0 07355 in of H2O cm of H2O 2 54 mm of Hg in of H2O 0 53524 Copyright 2016 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Отзывы: