background image

10

   

                                     

SDL720-en-GB_V1.0   12/16

 

Battery

 

Replacement

 

and

 

Disposal

 

When

 

the

 

low

 

battery

 

icon

 

 

appears

 

on

 

the

 

LCD,

 

the

 

batteries

 

must

 

be

 

replaced.

 

Several

 

hours

 

of

 

accurate

 

readings

 

are

 

still

 

possible

 

in

 

this

 

condition;

 

however,

 

batteries

 

should

 

be

 

replaced

 

as

 

soon

 

as

 

possible:

 

 

Remove

 

the

 

two

 

(2)

 

Phillips

 

screws

 

from

 

the

 

rear

 

of

 

the

 

meter

 

(directly

 

above

 

the

 

top

 

of

 

the

 

tilt

 

stand).

 

 

Remove

 

and

 

safely

 

place

 

the

 

battery

 

compartment

 

and

 

screws

 

where

 

they

 

will

 

not

 

be

 

damaged

 

or

 

lost.

 

 

Replace

 

the

 

six

 

(6)

 

1.5V

 

‘AA’

 

batteries

 

observing

 

correct

 

polarity.

 

 

Replace

 

the

 

battery

 

compartment

 

cover

 

with

 

the

 

two

 

(2)

 

Phillips

 

screws.

 

  

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Other

 

Battery

 

Safety

 

Reminders

 

o

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

o

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

 

  

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Содержание SDL720

Страница 1: ...User Manual Heavy Duty Differential Pressure Manometer Model SDL720 Additional User Manual Translations available at www extech com www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Страница 2: ...ustomer Support Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 P1 Input positive 2 P2 Input negative 3 LCD Display 4 HOLD and Backlight key 5 MAX MIN key 6 SET and Clock key 7 RS232 output jack 8 Reset button 9 Power Adaptor jack 10 SD card slot 11 ENTER and LOG key 12 Do...

Страница 3: ...he currently selected unit of measure is shown below the measurement value on the meter s LCD To change the unit of measure press and hold the UNIT button until the desired unit of measure appears and then release the UNIT button The meter begins scrolling through the available units of measure see table below after the UNIT button has been depressed for at least 1 5 seconds UNIT DISPLAY INDICATOR...

Страница 4: ... rate Hours Minutes Seconds PoFF Automatic power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 SdF Format the SD memory card Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys to change a value 3 Use the ENTER button to step through the selections 4 Press and ...

Страница 5: ...ter 2 Use the arrow buttons to select USA or EUro 3 Press ENTER to confirm setting 4 Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode or simply wait 7 seconds for the meter to automatically switch to the normal operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow buttons to select YES to format the card select NO to abort Note tha...

Страница 6: ...the meter displays a positive pressure reading if the P1 pressure is greater than P2 and a negative reading if P2 is greater than P1 Datalogging Types of Data Recording Manual Datalogging Manually log up to 99 readings onto an SD card via push button press Automatic Datalogging Automatically log data onto an SD memory card where the number of data points is virtually limited only by the card size ...

Страница 7: ...ero 2 Press and hold the LOG button for at least 1 5 seconds The meter will flash the DATALOGGER icon at the selected sampling rate indicating that readings are now being automatically recorded to the SD card 3 If a card is not inserted or if the card is defective the meter will display EMPTY and exit the DATALOGGER mode In this case switch the meter OFF and try again with a valid SD card 4 Pause ...

Страница 8: ...to a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example AC Power Adaptor This meter is normally powered by six 6 1 5V AA batte...

Страница 9: ...se Couplings This meter is supplied with a pair of hose couplings They fit 4 0mm 0 157 tubing See diagram on how to connect these couplings to the hose and the meter www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Страница 10: ...ery compartment cover with the two 2 Phillips screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take ...

Страница 11: ...en logging at a 1 second rate MANUAL LOGGING Set the sampling rate to 0 seconds Select 1 to 99 locations Data error number 0 1 number of total saved data Memory Card SD memory card 1G to 16GB size Data Hold Freeze the displayed reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Operating Temperature 0 to 50 C 32 to 122 F Operating Humidity ...

Страница 12: ...s H2O 0 5 20 40 m H2O 0 01 1 974 ATP 0 001 Conversions Useful conversion Factors From To Multiplier in of H2O in of Hg 0 07355 in of H2O cm of H2O 2 54 mm of Hg in of H2O 0 53524 Copyright 2016 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Отзывы: