background image

MO290-en-GB_V3.6   4/15 

Specifications 

Function Range 

Accuracy 

 

Pinless Moisture  

0 to 99.9 

Relative only 

External - Moisture in 
wood 

6-99 % 

± 5% 

External - Moisture in 
building materials 

13-99 % 

± 5% 

Pinless Depth 

Up to 0.75” (19mm) 

RH Measurement 

0 to 10% 

± 3%RH 

11 to 90% 

± 2.5%RH 

91 to 100% 

± 3%RH 

Air Temperature 

-20 to 170°F (-29 to 77°C) 

 3.6

F (2.0

C) 

IR Temp 

-4 to 31

F  

 9

 32°F 

  ± 

2°F 

 

33 to 392

F Greater 

of 

3.5% or 

9

 

-20 to-1

 4.5

 

0

 1

 

1 to 200

Greater of ±3.5% or ± 4.5°C 

 
Display 

3-digit primary display, 4-digit secondary display 

Vapor Pressure 

0 to 20.0kPA 

Dew Point 

-30 to 100°C (-22 to 199°F) 

Mixing Ratio 

0-999GPP (0 to 160g/kg) 

Sample Rate 

2 per second 

Backlight White 

LED 

Operating Temperature 

4 to 43°C (40 to 110°F) 

Storage Temperature 

-30 to 60°C (-14 to 140°F) 

Operating Humidity 

90%, 0-30°C (32-86°F), 75%, 30-40°C (86-104°F),  

 

45%, 40-50°C (104-122°F) 

Storage Humidity 

90% 

Power Supply 

9V battery 

Battery Life 

6-8 weeks (4 hrs/day use), using alkaline batteries 

Auto Power Off (APO) 

After 30 minutes (nominal) inactivity. The APO function can be disabled 
by the user. 

APO Quiescent Current 

50µA maximum 

Dimensions 165x70x38mm 

(6.5x2.8x1.5’) 

Weight 210g 

(7.4oz) 

 

Copyright

 

©

 

2014

2015

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

ISO

9001

 

Certified

 

www.extech.com

 

 