MEMORY 

The MEMORY menu allows for viewing data and naming/clearing data for up to 10 memory 
groups. Refer to the dedicated ‘Memory Logging Mode’ section later in this guide. 
 

ZERO MODE (Relative) 

The ZERO function allows measurements to be displayed as the difference between the actual 
reading and a stored reference reading. Follow the steps below: 

1.  From the normal measurement mode, take a moisture measurement that will represent the 

reference value. 

2.  With the meter continuing to take this reading press the MENU (F1) soft-key, scroll to the 

ZERO MODE field, and press the Enter key (the field color will change to blue indicating that 
the ZERO function is active). The current measurement has now been zeroed. 

3.  Return to the normal measurement mode by pressing the EXIT soft-key. Now, all 

subsequent readings will be displayed as on offset from the stored reference reading. For 
example, if the reference is 20 and a measurement of 50 is taken, the meter will display 30 
(50 actual reading minus 20 reference reading = 30 displayed reading).  

 

Note

: The REL icon will flash on the measurement display screen while the ZERO function 

is active. 

4.  To switch the ZERO function OFF, scroll to the ZERO MODE field again and press Enter 

(the field color will change to gray indicating that the ZERO function is switched OFF). 

 

Note

: The default state is ZERO MODE

 

OFF. 

 
  

F2 - MODE 

Repeated presses of the F2 MODE button allows scrolling through the three display modes: 
Digital display, Graphical Trend Analysis display, and Analog display. The digital display includes 
a bargraph at the bottom of the display. Note that the bargraph is color-coded where the alarm 
region is shown in red and the acceptable region in green. For more on the Trend Analysis 
display refer to the Trend Analysis section later in this guide. 

 

TREND                                         DIGITAL                                         ANALOG 

 

 
 
 
 
 

 

 

F3 

– HOLD/SAVE 

The HOLD menu freezes the displayed reading. When HOLD is pressed, two sub-menus SAVE 
and EXIT appear. Press EXIT to un-freeze the display and return the meter to the normal 
operating mode. Press SAVE to store the data to memory. 

 

Содержание MO270

Страница 1: ...User Guide Wireless Moisture Analyzer Model MO270...

Страница 2: ...ing materials using pins that are driven into the material under test The Sensor unit transmitter detaches from the Analyzer unit receiver for remote measurement operation This analyzer is shipped ful...

Страница 3: ...ve cap 7 Bluetooth capability 8 Includes two 2 3 7V rechargeable Li Polymer batteries one for Analyzer and one for Sensor wireless moisture Sensor unit external pin probe replacement pins telescoping...

Страница 4: ...r transmitter 4 Power button for sensor used only when sensor is disconnected from receiver 5 Lithium polymer battery shut off switch for Sensor transmitter used when shipping transporting the unit or...

Страница 5: ...BluetoothTM blue Active pairing Active BluetoothTM communication between receiver and peripheral device gray RF Wireless Wireless transmitter is ON sensor communication is INACTIVE orange RF wireless...

Страница 6: ...r 2 Charging the batteries using a PC USB port a With the Analyzer ON OFF switch turned ON connect the USB cable between the mini USB port on the Sensor or the Analyzer and a USB port on the PC Note t...

Страница 7: ...nsor into areas that are difficult or unsafe to reach Connect the sensor transmitter unit to the extender using the extender s mounting screw and the mounting screw hole on the sensor Note that extend...

Страница 8: ...T or BACK when done CHANNEL Setting Select the common channel over which a transmitter and receiver will communicate If several transmitters are owned a unique channel number can be used for each Note...

Страница 9: ...ght arrow keys to move the triangle shaped pointer to the digit that is to be changed 4 Use the up down arrows to change the digit s value Press to store the new value and to switch off the arrow poin...

Страница 10: ...keys to scroll over to the SCAN box for either the HIGH or the LOW Alarm limit When the SCAN box is highlighted press the button to automatically transpose the real time measurement to the Alarm limi...

Страница 11: ...measurement of 50 is taken the meter will display 30 50 actual reading minus 20 reference reading 30 displayed reading Note The REL icon will flash on the measurement display screen while the ZERO fu...

Страница 12: ...he SETTINGS mode only the visual alarm will trigger To silence an alarm go to the ALARM sub menu in the SETTINGS menu and select OFF for the alarm SOUND setting Trend Analysis Display Feature Press th...

Страница 13: ...Use the CLEAR button to delete a displayed reading Press F1 BACK to return to the Groups list or press EXIT to return to the normal operating mode Rename a Memory Group To rename a memory group press...

Страница 14: ...s device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference receive...

Страница 15: ...nt principle Electrical resistance pins Electromagnetic sensor pinless Measurement ranges 0 0 to 99 9 Relative pinless 7 0 to 99 3 WME pins Electrode pin length 0 75 22mm Electrode pin type Integrated...

Страница 16: ...4 Boxwood Maracaibo 1 Kauri Queensland 8 Camphorwood E African 3 Keruing 5 Canarium African 2 Kuroka 1 Cedar Japanese 2 Larch European 3 Cedar West Indian 8 Larch Japanese 3 Cedar Western Red 3 Larch...

Страница 17: ...rsimmon 6 Turpentine 3 Pillarwood 5 Utile 8 Pine American Long Leaf 3 Walnut African 8 Pine American Pitch 3 Walnut American 1 Pine Bunya 2 Walnut European 3 Pine Caribbean Pitch 3 Walnut New Guinea 2...

Страница 18: ...Fraxinus Americana 2 Bosquiera phoberos 1 Fraxinus excelsior 1 Brachylaena hutchinsii 8 Fraxinus japonicus 1 Brachystegia spp 2 Fraxinus mardshurica 1 Calophyllum brasiliense 7 Gonystylus macrophyllu...

Страница 19: ...18 28 mc 3 Thujopsis dolabrat 8 Picea jezoensis 8 18 mc 8 Tieghamella heckelii 2 Picea sitchensis 3 Tilia americana 6 Pinus caribaea 3 Tilia vulgaris 4 Pinus contorta 1 Triploehiton scleroxylon 6 Pin...

Страница 20: ...MO270 EU EN v2 1 11 12 20 Appendix B Menu Structure User Interface...

Страница 21: ...MO270 EU EN v2 1 11 12 21 Appendix B Menu Structure User Interface continued...

Отзывы: