Congratulations on your purchase of this Extech MA640 True RMS Clamp Meter. This meter 
measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty 
Cycle and Continuity. Special features include Thermocouple Temperature and Non-Contact Voltage 
detection. The double molded case is designed for heavy duty use. This meter is shipped fully tested 
and calibrated and, with proper use, will provide years of reliable service. 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer 
to the manual for further information. 
 
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present 
 
Double insulation 

 

This 

WARNING

 symbol indicates a potentially hazardous situation, which if not 

avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, which if not 

avoided, may result damage to the product. 

 
 
 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which 
measures are taken to limit the transient overvoltages to an appropriate low level. 

Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from 
the fixed installation. 

Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 

Note – Examples include switches in the fixed installation and some equipment for industrial use with 
permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 

Note – Examples include electricity meters and primary over-current protection equipment

 

WARNING 

CAUTION 

Содержание MA640

Страница 1: ...User s Guide 600Amp AC DC True RMS Clamp Meter Model MA640...

Страница 2: ...injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equip...

Страница 3: ...ore replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when ma...

Страница 4: ...RELATIVE Button 13 Battery compartment rear 14 Positive Input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current MAX Max reading MIN Min reading L...

Страница 5: ...tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may...

Страница 6: ...e side of the circuit 5 Read the voltage value in the display Resistance Measurements Note Remove power from the device under test before making resistance measurements 1 Rotate the function switch to...

Страница 7: ...ay OL the device is open If both readings are very small or 0 the device is shorted Capacitance Measurements WARNING To avoid electric shock discharge the capacitor before measuring 1 Rotate the funct...

Страница 8: ...position 2 Press the MODE button to select F or C 3 Insert the Temperature Probe into the input jacks 4 Place the temperature probe tip where needed 5 Read the temperature on the display Note In case...

Страница 9: ...seconds LCD Backlight The LCD is equipped with backlighting for easier viewing especially in dimly lit areas Press and hold the HOLD button for 2 seconds to turn the backlight on The backlight will au...

Страница 10: ...re remove the battery and store it separately Battery Replacement 1 Remove the Phillips head screws that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure...

Страница 11: ...0 0 VDC 0 1V Resistance 600 0 0 1 1 0 4 digits 6 000k 0 001k 1 5 2 digits 60 00k 0 01k 600 0k 0 1k 6 000M 0 001M 2 5 3 digits 60 00M 0 01M 3 5 5 digits Capacitance 40 00nF 0 01nF 4 0 20 digits 400 0nF...

Страница 12: ...ranges 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50...