Extech Instruments MA640 Скачать руководство пользователя страница 11

MA640-en-GB_V2.4   5/15 

11

Specifications 

Function Range 

 

Resolution 

Accuracy 

(% of r digits) 

AC Current 

50/60 Hz 

True RMS

 

 

60.00 AAC 

0.01A 

±(2.8% + 8 digits) 

600.0 AAC 

0.1A 

±(3.0% + 8 digits) 

DC Current 
 

60.00 AAC 

0.01A 

±(2.8% + 5 digits) 

600.0 ADC 

0.1A 

±(3.0% + 5 digits) 

AC Voltage 

True RMS

 

6.000 VAC 

0.001V 

±(1.8% + 8 digits) 

60.00 VAC 

0.01V 

600.0 VAC 

0.1V 

DC Voltage 

600.0 mVDC 

0.1mV 

±(1.5% + 2 digits) 

6.000 VDC 

0.001V 

60.00 VDC 

0.01V 

600.0 VDC 

0.1V 

Resistance 

600.0

 0.1

 

±(1.0% + 4 digits) 

6.000k

 0.001k

 

±(1.5% + 2 digits) 

60.00k

 0.01k

 

600.0k

 0.1k

 

6.000M

 0.001M

 

±(2.5% + 3 digits) 

60.00M

 0.01M

 

±(3.5% + 5 digits) 

Capacitance 

40.00nF 

0.01nF 

±(4.0% + 20 digits) 

400.0nF 0.1nF 

±(3.0% + 5 digits) 

4.000µF 0.001µF 

40.00µF 0.01µF 

400.0µF 

0.1µF 

±(4.0% + 10 digits) 

4000µF 

1µF 

±(5.0% + 10 digits) 

Frequency 

10Hz to 10kHz 

0.01Hz to 0.01khz 

±(1.5% + 2 digits) 

Sensitivity: 15Vrms 

Duty Cycle 

0.5% to 99.0% 

0.1% 

±(1.2% + 2 digits) 

Pulse width: 100

s to 100ms, Frequency: 10Hz to 10kHz 

Temperature 
Type K 

-4 to - 1400°F 

0.1° <800°; 1° >800° 

±3% r 9°F/5°C 

-20 to 760°C 

0.1° <400°; 1° >400° 

Specification does not include probe accuracy 

 
 

Содержание MA640

Страница 1: ...User s Guide 600Amp AC DC True RMS Clamp Meter Model MA640...

Страница 2: ...injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equip...

Страница 3: ...ore replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when ma...

Страница 4: ...RELATIVE Button 13 Battery compartment rear 14 Positive Input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current MAX Max reading MIN Min reading L...

Страница 5: ...tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may...

Страница 6: ...e side of the circuit 5 Read the voltage value in the display Resistance Measurements Note Remove power from the device under test before making resistance measurements 1 Rotate the function switch to...

Страница 7: ...ay OL the device is open If both readings are very small or 0 the device is shorted Capacitance Measurements WARNING To avoid electric shock discharge the capacitor before measuring 1 Rotate the funct...

Страница 8: ...position 2 Press the MODE button to select F or C 3 Insert the Temperature Probe into the input jacks 4 Place the temperature probe tip where needed 5 Read the temperature on the display Note In case...

Страница 9: ...seconds LCD Backlight The LCD is equipped with backlighting for easier viewing especially in dimly lit areas Press and hold the HOLD button for 2 seconds to turn the backlight on The backlight will au...

Страница 10: ...re remove the battery and store it separately Battery Replacement 1 Remove the Phillips head screws that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure...

Страница 11: ...0 0 VDC 0 1V Resistance 600 0 0 1 1 0 4 digits 6 000k 0 001k 1 5 2 digits 60 00k 0 01k 600 0k 0 1k 6 000M 0 001M 2 5 3 digits 60 00M 0 01M 3 5 5 digits Capacitance 40 00nF 0 01nF 4 0 20 digits 400 0nF...

Страница 12: ...ranges 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50...