Data Hold

To freeze the LCD meter reading, press the

HOLD

button. While data hold is active, the

HOLD

display icon appears on the LCD. Press the HOLD button again to return to normal

operation.

Backlight

Press and hold the

HOLD

button for >2 seconds to turn the backlight on/off.

Note:

The HOLD feature will activate when the backlight is turned on. Press the HOLD

button again to exit the Hold feature.

Zero

Button

Zeros Capacitance and DC Current measurements. Also allows the user to offset the
meter by using the displayed value as the zero reference value. Press the

ZERO

key

momentarily to activate and to exit Zero mode.

Maintenance

WARNING:

To avoid electrical shock, disconnect the meter from any circuit, remove the

test leads from the input terminals and turn OFF the meter before opening the case. Do
not operate with open case.

Cleaning and Storage

Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or
solvents. If the meter is not to be used for periods of longer than 60 days, remove the
batteries and store them separately

Battery Replacement

1.

Remove the two rear Phillips head screws

2.

Open the battery compartment

3.

Replace the two 1.5V AAA batteries.

4.

Re-assemble the meter

You, as the end user, are legally bound (

Battery ordinance

) to return all used

batteries and accumulators;

disposal in the household garbage is prohibited!

You can hand over your used batteries / accumulators at collection points in
your community or wherever batteries / accumulators are sold!

Disposal:

Follow the valid legal stipulations in respect of the disposal of the

device at the end of its lifecycle

Copyright © 2004 Extech Instruments Corporation.

All rights reserved including the right of reproduction in whole or in part in any form.

Содержание MA220

Страница 1: ...User s Guide 400A AC DC Clamp Meter Model MA220...

Страница 2: ...ltage to meter when resistance function is selected Set the function switch OFF when the meter is not in use Remove the battery if meter is to be stored for longer than 60 days WARNINGS Set function s...

Страница 3: ...000V 2 5 digits 40 00V 400 0V 600V 2 5 digits Resistance 400 0 1 0 4 digits 4 000k 1 5 2 digits 40 00k 400 0k 4 000 M 2 5 3 digits 40 00M 3 5 5 digits Capacitance 40 00nF 5 30 digits 400 0nF 3 5 digit...

Страница 4: ...per second nominal Input Impedance 7 8M V DC and V AC Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20o C to 60o C 4o F to 140o F Operating Humidity Max 80 up to 31 C 87 F decre...

Страница 5: ...Mode select button 8 Range select button 9 Hz Duty Cycle button 10 COM input jack 11 V Temp jack 12 Battery cover rear AC AC alternating current DC DC direct currrent Minus sign AUTO AutoRange mode ZE...

Страница 6: ...positive V Temp jack 3 Select AC or DC with the MODE button 4 Connect the test leads to the circuit under test 5 Read the voltage on the display The display will indicate the proper decimal point and...

Страница 7: ...uty Cycle Measurements 1 Turn the rotary switch to the Volts Hz position 2 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack...

Страница 8: ...the meter before opening the case Do not operate with open case Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is n...

Отзывы: