background image

MA140

en

GB_V1.0

   

1/15

 

3

CAUTIONS

 

CAUTIONS

 

identify

 

conditions

 

and

 

actions

 

that

 

could

 

cause

 

DAMAGE

 

to

 

the

 

meter

 

or

 

equipment

 

under

 

test.

 

Do

 

not

 

expose

 

the

 

meter

 

to

 

extremes

 

in

 

temperature

 

or

 

high

 

humidity.

 

Safety

 

Symbols

 

that

 

are

 

typically

 

marked

 

on

 

meters

 

and

 

instructions

 

 

This

 

symbol,

 

adjacent

 

to

 

another

 

symbol,

 

indicates

 

the

 

user

 

must

 

refer

 

to

 

the

 

manual

 

for

 

further

 

information.

 

 

Risk

 

of

 

electrical

 

shock

 

 

Do

 

not

 

apply

 

or

 

remove

 

clamp

 

from

 

HAZARDOUS

 

LIVE

 

conductors

 

 

Equipment

 

protected

 

by

 

double

 

or

 

reinforced

 

insulation

 

 

Battery

 

symbol

 

 

Conforms

 

to

 

EU

 

directives

 

 

Do

 

not

 

discard

 

this

 

product

 

in

 

household

 

trash.

 

 

AC

 

measurement

 

 

DC

 

measurement

 

 

Earth

 

ground

 

 

PER

 

IEC1010

 

OVERVOLTAGE

 

INSTALLATION

 

CATEGORY

 

OVERVOLTAGE

 

CATEGORY

 

I

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

I

 

is

 

equipment

 

for

 

connection

 

to

 

circuits

 

in

 

which

 

measures

 

are

 

taken

 

to

 

limit

 

the

 

transient

 

over

voltages

 

to

 

an

 

appropriate

 

low

 

level.

 

Note

 

 

Examples

 

include

 

protected

 

electronic

 

circuits.

 

OVERVOLTAGE

 

CATEGORY

 

II

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

II

 

is

 

energy

consuming

 

equipment

 

to

 

be

 

supplied

 

from

 

the

 

fixed

 

installation.

 

Note

 

 

Examples

 

include

 

household,

 

office,

 

and

 

laboratory

 

appliances.

 

OVERVOLTAGE

 

CATEGORY

 

III

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

III

 

is

 

equipment

 

in

 

fixed

 

installations.

 

Note

 

 

Examples

 

include

 

switches

 

in

 

the

 

fixed

 

installation

 

and

 

some

 

equipment

 

for

 

industrial

 

use

 

with

 

permanent

 

connection

 

to

 

the

 

fixed

 

installation.

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

is

 

for

 

use

 

at

 

the

 

origin

 

of

 

the

 

installation.

 

Note

 

 

Examples

 

include

 

electricity

 

meters

 

and

 

primary

 

over

current

 

protection

 

equipment

 

www.

.com

[email protected]

1.800.561.8187

Содержание MA140

Страница 1: ...USER GUIDE True RMS 300A AC Mini Clamp Meter with Non Contact Voltage Detector Model MA140 www com information itm com 800 561 8187...

Страница 2: ...Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible If the equipment is used in a manner not specifi...

Страница 3: ...TEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include...

Страница 4: ...play digits 3 In Rush Current mode 4 Low Pass Filter 5 Data Hold 6 AC Measurement 7 Amperes current 8 Battery status icon 9 Minus negative sign Control Button Description Press for 2 seconds to access...

Страница 5: ...o the next section Note The meter displays the battery capacity when powering up Disable Auto Power OFF The meter will auto power OFF after 20 minutes of inactivity To defeat this feature follow the s...

Страница 6: ...ess the AC Current measurement mode The A symbol will appear on the display in the lower right hand side indicating Amperes Amps 2 Press the jaw trigger to open the clamp jaw 3 Position the clamp arou...

Страница 7: ...ast 5A is detected 4 To exit the Inrush Current mode press the INRUSH button again momentarily The INRUSH icon will switch OFF 100ms Sample Window Measured Inrush Sample time trigger Inrush Button Pre...

Страница 8: ...ontact Voltage Detect mode 2 Note the voltage detection display icons as shown in the Description section of this guide 3 Place the meter near a source of electrical energy The tip of the clamp offers...

Страница 9: ...teries observing correct polarity 4 Re assemble the meter before use 5 Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix batte...

Страница 10: ...tion Accuracy of reading Inrush Current 300 0 A 0 1 3 5 5 digits Integration time 100ms Trigger current threshold 5A Volt Detection 80V 600VAC n a n a The tip of the clamp offers the optimum sensitivi...

Страница 11: ...ture Coefficient 0 2 x specified accuracy C 20 C 68 F 26 C 79 F Operating Altitude 2000m 6562ft Battery power 2 LR 44 1 5V batteries battery life 50 hours typical Weight 140g 4 9 oz Dimensions 60 x 14...

Отзывы: