background image

 

 

 

IR267

en

GB_v1.1

   

8/16

 

10

Maintenance

 

Cleaning

 

To

 

clean

 

the

 

lenses,

 

use

 

compressed

 

air

 

to

 

clear

 

dust

 

and

 

other

 

particles,

 

then

 

carefully

 

clean

 

with

 

a

 

wet

 

cotton

 

swab.

 

The

 

cotton

 

swab

 

should

 

be

 

moistened

 

with

 

clean

 

water.

 

To

 

clean

 

the

 

meter

 

housing,

 

wipe

 

with

 

a

 

damp,

 

soft

 

cloth.

 

Do

 

not

 

use

 

solvents

 

or

 

abrasives.

 

Do

 

not

 

immerse

 

the

 

IR267

 

in

 

water

 

or

 

other

 

liquid.

 

Troubleshooting

 

Symptom

 

Problem

Action

OL

 

display

 

Target

 

temperature

 

exceeds

 

range

 

Select

 

a

 

target

 

within

 

range

OL

 

display

 

Target

 

temperature

 

under

range

 

Select

 

a

 

target

 

within

 

range

Battery

 

icon

 

flashes

 

Low

 

Battery

 

power

Replace

 

Battery

Blank

 

display

 

screen

 

Low

 

battery

 

power

Check

 

and/or

 

replace

 

battery

 

Incorrect/No

 

displayed

 

value

 

Wrong

 

measurement

 

function

 

selected

Press

 

Up/Down

 

arrow

 

to

 

select

 

correct

 

measurement

 

function

 

No

 

Laser

 

pointer

 

Low

 

battery

 

Ensure

 

that

 

the

 

Laser

 

(LAS)

 

is

 

set

 

to

 

ON

 

in

 

the

 

Settings

 

mode

 

Replace

 

the

 

battery

 

Display

 

freezes/undefined

 

reading

 

Locked

 

display

Turn

 

the

 

meter

 

OFF

 

then

 

pull

 

trigger

 

again

 

after

 

3

 

seconds

 

Battery

 

Replacement

 

When

 

the

 

battery

 

icon

 

flashes,

 

or

 

when

 

the

 

meter

 

doesn’t

 

switch

 

ON,

 

replace

 

the

 

battery:

 

 

The

 

battery

 

compartment

 

is

 

located

 

in

 

the

 

hand

 

grip.

 

 

 

The

 

battery

 

compartment

 

lid

 

is

 

located

 

just

 

below

 

the

 

trigger.

 

 

Open

 

the

 

battery

 

door

 

by

 

prying

 

with

 

a

 

thumb

 

or

 

finger

 

at

 

one

 

of

 

the

 

indentations

 

near

 

the

 

top

 

of

 

the

 

hand

 

grip.

 

 

The

 

door

 

is

 

hinged

 

at

 

the

 

bottom

 

of

 

the

 

hand

 

grip.

 

 

The

 

battery

 

should

 

be

 

installed

 

with

 

the

 

positive

 

+

 

terminal

 

(smaller

 

contact)

 

facing

 

the

 

meter

 

to

 

ensure

 

correct

 

polarity.

 

 

Safety:

 

Please

 

dispose

 

of

 

batteries

 

responsibly;

 

never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire,

 

batteries

 

may

 

explode

 

or

 

leak.

 

If

 

the

 

meter

 

is

 

not

 

to

 

be

 

used

 

for

 

60

 

days

 

or

 

more,

 

remove

 

the

 

battery

 

and

 

store

 

separately.

 

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Other

 

Battery

 

Safety

 

Reminders

 

o

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

o

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

www.

.com

[email protected]

1.800.561.8187

Содержание IR267

Страница 1: ...USER MANUAL Mini InfraRed IR Thermometer with Type K Input and Laser Pointer MODEL IR267 www com information itm com 1 800 561 8187 ...

Страница 2: ... with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features Measures non contact surface temperature up to 1112 F 600 C Measures ambient air temperature to 158 F 70 C Type K thermocouple input offers contact temperature measurements 12 1 Distance...

Страница 3: ...mometer near explosive gases steam or dust o Note that an object with high reflectivity will normally cause the measured temperature value to read much lower than the actual temperature o Use the device only as described in this User Guide Cautions To avoid thermometer damage please avoid the following hazards o EMF from welding equipment or electro induction heaters o Static electricity o Thermal...

Страница 4: ...ft for Emissivity value Emissivity value indication Laser pointer active S Scan mode active while the trigger is pulled displayed temperature tracks the temperature of the scanned surfaces H Hold mode displayed temperature freezes with trigger release Max Min Avg Diff Maximum Minimum Average Differential temperature readings Battery capacity indicator flashes when battery voltage is critical K A O...

Страница 5: ...ding as selected in the Settings mode 5 The meter defaults to the settings in use when the meter was last switched OFF Ambient Air Temperature Measurements The IR267 can measure the temperature of ambient air using the recessed temperature sensor located on the front of the meter next to the laser pointer lens 1 Pull and hold the Trigger to keep the meter powered 2 Use the UP or DOWN button to sel...

Страница 6: ...atio Field of View The meter s field of view is 12 1 distance to spot ratio For example if the meter is 24 inches from the target spot the diameter of the target must be at least 2 inches Other distances are shown below in the field of view diagram Note that measurements should normally be made 2 feet from the target The meter can measure from further distances but the measurement may be affected ...

Страница 7: ...nt matches the contact measurement Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0 90 to 0 98 Cloth black 0 98 Concrete 0 94 Skin human 0 98 Cement 0 96 Leather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Soil 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 ...

Страница 8: ... Laser ON OFF Pull the trigger and release Use the M button to step to the LAS display Use the SET button to select oN or oFF Pull the trigger to return to the normal operating mode When the laser is ON the laser icon will appear on the LCD HIGH Temperature Alarm Limit Setting Pull the trigger and release Use the M button to step to Alm H Use the arrow buttons to set the High Alarm limit Press the...

Страница 9: ...et size calculated using the field of view diagram 2 If the surface of the object under test is covered with frost oil grime etc clean before taking measurements 3 If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring 4 The meter cannot make accurate measurements through transparent surfaces such as glass 5 Steam dust smoke etc can obscu...

Страница 10: ...eplace the battery The battery compartment is located in the hand grip The battery compartment lid is located just below the trigger Open the battery door by prying with a thumb or finger at one of the indentations near the top of the hand grip The door is hinged at the bottom of the hand grip The battery should be installed with the positive terminal smaller contact facing the meter to ensure cor...

Страница 11: ...ength is 630 670nm IR Spectral response 8 14 mm wavelength The supplied thermocouple is rated for 250o C 482o F maximum temperature To measure higher temperatures please obtain a Type K thermocouple rated for the desired temperature General Specifications Display Backlit multifunction LCD display Display update rate 1 second approx Operating Temperature 0o C 50o C 32o F 122o F Operating Humidity 1...