background image

 

 

 

IR267

en

GB_v1.1

   

8/16

 

9

Selecting

 

the

 

Temperature

 

Unit

 

of

 

Measure

 

(°C/°F)

 

Pull

 

the

 

trigger

 

and

 

release.

 

Use

 

the

 

M

 

button

 

to

 

step

 

to

 

°C/°F

.

 

Use

 

the

 

SET

 

button

 

to

 

select

 

°C

 

or

 

°F

.

 

Pull

 

the

 

trigger

 

to

 

return

 

to

 

the

 

normal

 

operating

 

mode.

 

Setting

 

the

 

Alarm

 

Buzzer

 

‘bU2’

 

ON/OFF

 

Pull

 

the

 

trigger

 

and

 

release.

 

Use

 

the

 

M

 

button

 

to

 

step

 

to

 

bU2

’.

 

Use

 

the

 

SET

 

button

 

to

 

select

 

ON

 

or

 

OFF

.

 

Pull

 

the

 

trigger

 

to

 

return

 

to

 

the

 

normal

 

operating

 

mode.

 

When

 

set

 

to

 

OFF,

 

the

 

Alarm

 

buzzer

 

will

 

not

 

sound

 

in

 

an

 

alarm

 

condition.

 

 

Measurement

 

Notes

 

1.

 

The

 

object

 

under

 

test

 

should

 

be

 

larger

 

than

 

the

 

spot

 

(target)

 

size

 

calculated

 

using

 

the

 

field

 

of

 

view

 

diagram.

 

2.

 

If

 

the

 

surface

 

of

 

the

 

object

 

under

 

test

 

is

 

covered

 

with

 

frost,

 

oil,

 

grime,

 

etc.,

 

clean

 

before

 

taking

 

measurements.

 

3.

 

If

 

an

 

object's

 

surface

 

is

 

highly

 

reflective

 

apply

 

masking

 

tape

 

or

 

flat

 

black

 

paint

 

to

 

the

 

surface

 

before

 

measuring.

 

4.

 

The

 

meter

 

cannot

 

make

 

accurate

 

measurements

 

through

 

transparent

 

surfaces

 

such

 

as

 

glass.

 

5.

 

Steam,

 

dust,

 

smoke,

 

etc.

 

can

 

obscure

 

measurements.

 

6.

 

The

 

meter

 

compensates

 

for

 

deviations

 

in

 

ambient

 

temperature.

 

It

 

can,

 

however,

 

take

 

up

 

to

 

30

 

minutes

 

for

 

the

 

meter

 

to

 

adjust

 

to

 

extremely

 

wide

 

ambient

 

temperature

 

changes.

 

7.

 

To

 

find

 

a

 

hot

 

spot,

 

aim

 

the

 

meter

 

outside

 

the

 

area

 

of

 

interest

 

then

 

scan

 

across

 

(in

 

an

 

up

 

and

 

down

 

motion)

 

until

 

the

 

hot

 

spot

 

is

 

located.

 

www.

.com

[email protected]

1.800.561.8187

Содержание IR267

Страница 1: ...USER MANUAL Mini InfraRed IR Thermometer with Type K Input and Laser Pointer MODEL IR267 www com information itm com 1 800 561 8187 ...

Страница 2: ... with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features Measures non contact surface temperature up to 1112 F 600 C Measures ambient air temperature to 158 F 70 C Type K thermocouple input offers contact temperature measurements 12 1 Distance...

Страница 3: ...mometer near explosive gases steam or dust o Note that an object with high reflectivity will normally cause the measured temperature value to read much lower than the actual temperature o Use the device only as described in this User Guide Cautions To avoid thermometer damage please avoid the following hazards o EMF from welding equipment or electro induction heaters o Static electricity o Thermal...

Страница 4: ...ft for Emissivity value Emissivity value indication Laser pointer active S Scan mode active while the trigger is pulled displayed temperature tracks the temperature of the scanned surfaces H Hold mode displayed temperature freezes with trigger release Max Min Avg Diff Maximum Minimum Average Differential temperature readings Battery capacity indicator flashes when battery voltage is critical K A O...

Страница 5: ...ding as selected in the Settings mode 5 The meter defaults to the settings in use when the meter was last switched OFF Ambient Air Temperature Measurements The IR267 can measure the temperature of ambient air using the recessed temperature sensor located on the front of the meter next to the laser pointer lens 1 Pull and hold the Trigger to keep the meter powered 2 Use the UP or DOWN button to sel...

Страница 6: ...atio Field of View The meter s field of view is 12 1 distance to spot ratio For example if the meter is 24 inches from the target spot the diameter of the target must be at least 2 inches Other distances are shown below in the field of view diagram Note that measurements should normally be made 2 feet from the target The meter can measure from further distances but the measurement may be affected ...

Страница 7: ...nt matches the contact measurement Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0 90 to 0 98 Cloth black 0 98 Concrete 0 94 Skin human 0 98 Cement 0 96 Leather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Soil 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 ...

Страница 8: ... Laser ON OFF Pull the trigger and release Use the M button to step to the LAS display Use the SET button to select oN or oFF Pull the trigger to return to the normal operating mode When the laser is ON the laser icon will appear on the LCD HIGH Temperature Alarm Limit Setting Pull the trigger and release Use the M button to step to Alm H Use the arrow buttons to set the High Alarm limit Press the...

Страница 9: ...et size calculated using the field of view diagram 2 If the surface of the object under test is covered with frost oil grime etc clean before taking measurements 3 If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring 4 The meter cannot make accurate measurements through transparent surfaces such as glass 5 Steam dust smoke etc can obscu...

Страница 10: ...eplace the battery The battery compartment is located in the hand grip The battery compartment lid is located just below the trigger Open the battery door by prying with a thumb or finger at one of the indentations near the top of the hand grip The door is hinged at the bottom of the hand grip The battery should be installed with the positive terminal smaller contact facing the meter to ensure cor...

Страница 11: ...ength is 630 670nm IR Spectral response 8 14 mm wavelength The supplied thermocouple is rated for 250o C 482o F maximum temperature To measure higher temperatures please obtain a Type K thermocouple rated for the desired temperature General Specifications Display Backlit multifunction LCD display Display update rate 1 second approx Operating Temperature 0o C 50o C 32o F 122o F Operating Humidity 1...