background image

EX35x

en

GB_V1.2

   

12/15

 

22

6.

 

Specifications

 

ELECTRICAL

 

SPECIFICATIONS

 

Accuracy

 

is

 

given

 

as

 

±

 

(%

 

of

 

reading

 

+

 

least

 

significant

 

digit)

 

at

 

23

C

 

±5

C

 

with

 

relative

 

humidity

 

lower

 

than

 

80%.

 

Accuracy

 

is

 

specified

 

for

 

a

 

period

 

of

 

one

 

year

 

after

 

calibration.

 

1.

 

Temperature

 

Coefficient

 

is

 

0.1

 

x

 

specified

 

accuracy

 

/

 

C,

 

<

 

18

C

 

(64.5

F),

 

>

 

28

C

 

(82.4

F)

 

2.

 

AC

 

Functionality:

 

ACV

 

and

 

ACA

 

specifications

 

are

 

AC

 

coupled,

 

True

 

RMS,

 

45

 

to

 

400Hz;

 

For

 

non

sinusoidal

 

waveforms,

 

additional

 

accuracy

 

Crest

 

Factor

 

(C.F.)

 

considerations

 

exist

 

as

 

detailed

 

below:

 

Add

 

3.0%

 

for

 

C.F.

 

1.0~2.0;

 

Add

 

5.0%

 

for

 

C.F.

 

2.0~2.5;

 

Add

 

7.0%

 

for

 

C.F.

 

2.5~3.0

 

 

Function

 

Range

 

Resolution

 

Accuracy

 

DC

 

Voltage

 

EX350

 

EX355

 

40.00mV

 

60.00mV

 

10

μ

V

 

±(0.7

%+

5

 

digits

 

400.0mV

 

600.0mV

 

0.1mV

 

±(0.5

%+

2

 

digits

 

4.000V

 

6.000V

 

1mV

 

±(0.5

%+

3

 

digits

 

40.00V

 

60.00V

 

10mV

 

400.0V

 

600.0V

 

0.1V

 

600V

 

600V

 

1V

 

Input

 

Impedance:

 

10M

 

(1G

Ω 

for

 

mV

 

range);

 

Overload

 

Protection:

 

AC/DC

  

600V

 

AC

 

Voltage

 

40.00mV

 

60.00mV

 

10

μ

V

 

±(1.0

%+

3

 

digits

 

400.0mV

 

600.0mV

 

0.1mV

 

4.000V

 

6.000V

 

1mV

 

±(0.8

%+

3

 

digits

 

40.00V

 

60.00V

 

10mV

   

400.0V

 

600.0V

 

0.1V

 

600V

 

600V

 

1V

 

±(1.0

%+

3

 

digits

 

LPF

 

400.0V

 

600.0V

 

0.1V

 

±(4.0

%+

3

 

digits

 

LoZ

 

600V

 

600V

 

‐‐‐‐‐‐‐ 

±(1.2

%+

5

 

digits

 

Maximum

 

input

 

voltage:

 

±600Vrms

Input

 

impedance:

 

10M

Ω 

for

 

all

 

ranges

 

(ACV

 

frequency

 

response

 

is

 

45~400Hz)

 

Allow

 

the

 

meter

 

to

 

stabilize

 

for

 

10

 

minutes

 

after

 

using

 

LoZ

 

(low

 

impedance)

 

mode

 

Accuracy

 

stated

 

for

 

5

 

to

 

100%

 

of

 

range

 

 

 
 

Содержание EX350

Страница 1: ...USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature...

Страница 2: ...s 10 10A AC DC Current Measurements 12 mA A AC DC Current Measurements 13 Non Contact Voltage Detector 14 Resistance Measurements 15 Continuity Measurements 16 Capacitance Measurements 16 Lo Z AC Volt...

Страница 3: ...liable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features 6000 count EX355 or 4000 co...

Страница 4: ...r Guide Use caution working with voltages above 30 VAC RMS 42 VAC peak or 60 VDC These voltages pose a shock hazard To avoid misleading readings that could lead to electric shock and injury replace th...

Страница 5: ...s in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic circuits OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATE...

Страница 6: ...on 4 Hz button 5 Mode and LPF Button 6 Rotary function select switch 7 10A input terminal 8 uA and mA input terminal 9 Common input terminal 10 Positive input terminal Voltage Resistance Capacitance T...

Страница 7: ...o F Temperature units F Farads Capacitance measurement units Hz Hertz Frequency measurements unit Duty Cycle AC only Ohms Resistance measurement unit LPF Variable frequency voltage mode Battery status...

Страница 8: ...AC DC TEMP EX355 C F Press and Hold LPF in the ACV function to select variable frequency tests Press R Range to switch from Auto to Manual Range Hold to return to Auto Range Press activates Relative m...

Страница 9: ...r OFF after 15 minutes of inactivity To defeat this feature follow the steps below 1 With the meter OFF press and hold the M MODE button and while continuing to hold turn the rotary function switch to...

Страница 10: ...r DC EX355 only 4 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual range mode Press the R button to step through the ranges Press and hold the R...

Страница 11: ...test Be sure to observe the correct polarity red lead to positive black lead to negative 6 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual rang...

Страница 12: ...s and Hold the R button to return to the Auto Range mode 5 Current measurements must be taken in series with the circuit under test See accompanying diagram 6 Touch the black test lead to the negative...

Страница 13: ...ss the R button to manually range the meter Press the R button to step through the ranges Press and Hold the R button to return to the Auto Range mode 4 Press the M button to select AC or DC 5 Current...

Страница 14: ...e meter does not emit a tone or flash the LED in this mode there is still the possibility that voltage is present Please use caution 1 Turn the function switch to the NCV position to access the Non Co...

Страница 15: ...icon showing 4 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual range mode Press the R button to step through the ranges Press and Hold the R bu...

Страница 16: ...e Measurements WARNING To avoid electric shock remove power to the circuit under test and discharge the capacitor under test before measuring Do not test on circuits or devices where 60VDC or 30VAC is...

Страница 17: ...proper decimal point and measurement type units symbols Variable Frequency Voltage Measurements When the function switch is turned to the LPF position the meter can measure voltage on signals with va...

Страница 18: ...e LCD when in Diode test mode 3 Touch the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 Reverse the test lead polarity by reversing the red and black leads...

Страница 19: ...rving correct polarity 2 Turn the function switch to the Temp position Use the M button to select the desired unit of measure 3 Touch the temperature probe tip to the device under test or leave the te...

Страница 20: ...active Subsequent readings will now be compared to the stored reference Displayed Reading Measurement minus Reference Press the REL button again to exit the Relative mode the Relative symbol will swit...

Страница 21: ...y and store separately Fig 5 1 BATTERY AND FUSE REPLACEMENT Fuse Replacement The 600mA fuse can be replaced from the battery compartment 4 To replace the 10A fuse remove the four 4 screws that secure...

Страница 22: ...0 2 5 Add 7 0 for C F 2 5 3 0 Function Range Resolution Accuracy DC Voltage EX350 EX355 40 00mV 60 00mV 10 V 0 7 5 digits 400 0mV 600 0mV 0 1mV 0 5 2 digits 4 000V 6 000V 1mV 0 5 3 digits 40 00V 60 00...

Страница 23: ...y A EX350 EX355 400 0 A 600 0 A 0 1 A 1 0 3 digits 4000 A 6000 A 1 A mA 40 00mA 60 00mA 10 A 400 0mA 600 0mA 0 1mA A 4 000A 6 000A 1mA 1 2 3 digits 10 00A 10 00A 10mA ACA Frequency Response 45 400Hz F...

Страница 24: ...quency for Voltage or Current functions Frequency 1kHz AC voltage input amplitude of mV range 100mV input amplitude of V range the range 6 AC current input amplitude a 4000 6000 A 400 600mA 10A range...

Страница 25: ...C 86 to 104 F 50 RH maximum Storage Temperature and Humidity 10 to 50 C 14 to 122 F 80 RH maximum with battery removed Operating Altitude 2000m 6562 Battery power 2 AA batteries battery life 130 hours...

Отзывы: