Specifications

 

General

 

Specifications

 

Circuit

 

Custom

 

one

chip

 

LSI

 

microprocessor

 

circuit

 

Display

 

Dual

 

function

 

LCD

 

Dimensions:

 

44mm

 

X

 

29mm

 

(1.73

 

x

 

1.14”)

 

Measurements

 

Conductivity,

 

TDS,

 

Temperature

 

Data

 

hold

 

Data

 

hold

 

freezes

 

displayed

 

reading

 

Memory

 

recall

 

Min/Max

 

readings

 

store

 

and

 

recall

 

Auto

 

power

 

off

 

Meter

 

switches

 

off

 

after

 

10

 

minutes

 

(can

 

be

 

disabled)

 

Sample

 

rate

 

1

 

second

 

(approx.)

 

Operating

 

conditions

 

Temperature:

 

0

 

to

 

50

 

°C

 

(32

 

to

 

122

 

°F);

 

Humidity:

 

<

 

80%

 

RH

 

Battery

 

power

 

9V

 

alkaline

 

battery

 

Power

 

Consumption

 

Approx.

 

6.0

 

mA

 

DC

 

Weight

 

295

 

g

 

(0.65

 

lbs.)

 

including

 

batteries

 

&

 

probe

 

Dimensions

 

Meter:

 

135

 

x

 

60

 

x

 

33mm

 

(5.3

 

x

 

2.4

 

x1.3")

 

Probe:

 

22mm

 

(0.87”)

 

diameter

 

x

 

120mm

 

(4.72”)

 

length

 

 

 

Electrical

 

Specifications

 

Measurement

 

Range

 

Resolution

 

Accuracy

  

Conductivity

 

20.00mS/100.0mS/2000

 

uS

 

0.01mS/0.1mS/1uS

 

+

 

(2%FS+1dgt)

 

TDS

 

1,200/12,000/66,000

 

ppm

 

1/10/100ppm

 

+

 

(2%FS+1dgt)

 

Automatic

 

Temperature

 

Compensation

 

range

 

0

 

to

 

50

o

C

 

(32

 

to

 

122

 

o

F)

 

 
 
 

Copyright

 

©

 

2014

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

www.extech.com

 

 

  

 

Содержание EC210

Страница 1: ...User Guide Conductivity Meter Model EC210 ...

Страница 2: ...er Guide Features Three ranges 2000uS 20mS and 100mS with auto range functionality Conductivity TDS and temperature measurement functions Detachable probe for ease of use in a variety of measurement environments User adjustable automatic temperature compensation set to 0 for uncompensated Conductivity measurements Carbon rod electrode type for longevity LCD display shows Conductivity and Temperatu...

Страница 3: ...5 6 7 8 9 Meter Description 1 Main measurement display 2 Temperature reading 3 Power Escape button 4 Function Hold Up arrow button 5 Record Enter button 6 Setting down arrow button 7 Battery compartment rear 8 Probe connection 9 Probe ...

Страница 4: ...l show END if the electrode does not detect an appropriate solution value 8 While the CAL icon is flashing use the arrow buttons to adjust the displayed Conductivity reading to match the Conductivity value of the solution 9 After a few seconds the meter will display END Calibration is complete Conductivity Measurements Measurement Preparation Before taking measurements perform the calibration desc...

Страница 5: ...ctions on selecting o C o F temperature units and for adjusting the automatic temperature compensation Data Hold Press the Function Hold key to freeze the displayed value The LCD will display HOLD along with the held reading Press the Hold key again to release the data hold function MIN MAX Data Recording When selected the Data Recording function records the Min and Max readings 1 Press the REC bu...

Страница 6: ...ture Compensation Percent Setting SEt When the display shows SEt press ENTER SEt will flash and the upper display will show the temperature compensation percent Use the and buttons to set the desired temperature compensation percentage After selecting the desired value press ENTER to save the data The display now shows the temperature units Continue below Temperature Units Select The lower display...

Страница 7: ...tall a new 9V battery by snapping the battery terminals onto the wired connectors observing correct polarity and inserting the battery into the compartment lid chamber 5 Install the compartment lid chamber into the meter housing and secure with the two screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries ...

Страница 8: ...rature 0 to 50 C 32 to 122 F Humidity 80 RH Battery power 9V alkaline battery Power Consumption Approx 6 0 mA DC Weight 295 g 0 65 lbs including batteries probe Dimensions Meter 135 x 60 x 33mm 5 3 x 2 4 x1 3 Probe 22mm 0 87 diameter x 120mm 4 72 length Electrical Specifications Measurement Range Resolution Accuracy Conductivity 20 00mS 100 0mS 2000 uS 0 01mS 0 1mS 1uS 2 FS 1dgt TDS 1 200 12 000 6...

Отзывы: