background image

EA25 v3.1   8/13 

2

Introduction 

Congratulations on your purchase of the Extech EA25 EasyView Digital Hygro-Thermometer 
Datalogger. This device measures and records Humidity, Temperature, Dew Point, and Wet Bulb 
data in real-time. Careful use of this meter will provide years of reliable service. 
 

Specifications 

Function 

Range and Resolution 

Accuracy 

Humidity

 

10.0 to 95.0% RH 

±3% RH (at 25

o

C, 30 to 95% RH ) 

±5% RH (at 25

o

C, 10 to 30% RH ) 

Temperature*

  -4 to 140

o

F (-20 to 60

o

C) ±1.8

o

F (±1

o

C) 

 

Display  

Multifunction LCD with bargraph and status indicators 

Sensor Type   

Humidity: capacitance sensor; Temperature: thermistor 

Response Time 

Humidity: 45% to 95% < 1 min; 95% to 45% < 3 min. 
Temperature: Approx. 2 seconds for a 10

o

C change 

Reading Rate   

2 readings per second 

RS-232 PC Interface 

Optical connection with supplied interface cable. Software compatible 
with Windows

TM

 XP, Vista and  Windows 7 systems 

Datalogger storage 

Stores 99 sets of data in manual mode (15,000 in auto mode) 

Sampling Intervals 

3 to 255 seconds (1 to 86,400 sec. using supplied software)   

Operating Conditions

 

32 to 140

o

F (0 to 60

o

C); < 95% RH non-condensing 

Storage Conditions

 

14 to 140

o

F (-10 to 60

o

C); <70% RH non-condensing 

Power Supply   

6 x 1.5V ‘AAA’ batteries 

Auto power off  

After 30 minutes of inactivity 

Battery Life 

 

Approx. 200 hours 

Dimensions / Weight

 

5.9 x 2.8 x 1.4” (150 x 72 x 35mm); 8.3 oz. (235g) 

 

Содержание EA25

Страница 1: ...User s Guide EasyView Digital Hygro Thermometer Datalogger Model EA25 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...ce sensor Temperature thermistor Response Time Humidity 45 to 95 1 min 95 to 45 3 min Temperature Approx 2 seconds for a 10 o C change Reading Rate 2 readings per second RS 232 PC Interface Optical connection with supplied interface cable Software compatible with Windows TM XP Vista and Windows 7 systems Datalogger storage Stores 99 sets of data in manual mode 15 000 in auto mode Sampling Interval...

Страница 3: ...button 6 Humidity Temperature select button 7 SET button 8 Units C F select button 9 MEM memory button 10 ENTER button 11 READ button 12 DEW POINT temperature select left arrow button 13 UP DOWN programming keys 14 WET BULB temperature select right arrow button 15 RS 232 optical jack 16 The battery compartment is located on the rear of the instrument 9 3 6 4 7 8 5 2 1 ...

Страница 4: ... button allows the user to view the elapsed time for a particular MX or MN reading in Minutes Seconds 59mins 59secs max or Days Hours 99days 24hours max 4 To check the highest and lowest Dew Point or Wet Bulb temperatures use the DEW and the WET buttons 5 The following data displays are available in the MX MN mode Maximum and Minimum Humidity with the associated Temperature Maximum and Minimum Tem...

Страница 5: ... has been downloaded otherwise it will be lost Up to 15 000 sets of data can be recorded in automatic datalogging mode ALL of the following settings must be configured before datalogging Real Time Clock Set to the current time in hours minutes and seconds Start Time Set the time that datalogging will automatically begin Stop Time Set the time that datalogging will automatically stop Interval Time ...

Страница 6: ...ired minute that datalogging will end 5 Press to move to the two flashing digits representing seconds 6 Press or to set the desired second that datalogging will end 7 Press enter key to store the datalogging stop time and move to the next screen Datalogging Sampling Interval Setting 1 INTV interval appears along with the current interval selection in seconds 2 Use the or buttons to change the numb...

Страница 7: ...cations chart earlier in this manual Battery Replacement When the battery power falls low the BT symbol will appear on the LCD Replace the six 1 5 AAA batteries by removing the rear battery compartment screw and accessing the battery compartment Check that the polarity orientation is correct when placing the batteries in the compartment Ensure that the compartment cover is securely fastened when f...

Отзывы: